Manuale d’uso / di manutenzione del prodotto PN 2063508 del fabbricante Fluke
Vai alla pagina of 31
® PN 2063508 January 2003 © 2003 Fluke C orpor ation. Al l rig hts reserv ed. P rinted in Chin a. All produc t nam es are tr adem arks of the ir res pective c ompa nies.
i Table of Contents Title Page READ FIRST: SAFETY INFORMATION .................................................... 1 SYMBOLS .................................................................................................. 2 DISPLAY .................
12 Multimeter Users M anual ii Recording Min imum and Max imum Readi ng with El apsed Tim e ............ 19 Capturing Con tinuity Interm ittents with Cont inuity Capture .................. 21 TURNING BEEPER OFF.....................................
1 READ FIRST: SAFETY INFORMATION This meter has been des igned a nd tested i n acc ordance wit h IEC Publicat ion 1010 . To ensure that th e meter is used s afely, follow all s afety an d operating i nstruc tions in this manual. If th e meter is n ot used as desc ribed in th is manua l, the s afety features of the meter might be im paired.
12 Multimeter Users Manual 2 SYMBOLS The followi ng inter nationa l elec trical sy mbols are us ed in t his m anual: W Important Safe ty Informat ion in Manual ∅ Not Applic able to I dentifie d Mode.
12 Multimeter DISPL AY 3 DISPLAY Figure 1. D isplay.
12 Multimeter Users Manual 4 OPERATING FEATURES Figure 2. Operating Features.
12 Multimeter STAND BY MOD E 5 STANDBY MOD E In standby m ode, the dis play goes blank to preserv e battery life. Th e meter beeps and enters Standby if it is O N but inac tive f or more than 45 minutes . Press any pushbu tton to resume op eration. Standby is n ot allowe d if the met er is in the MIN M AX mode.
12 Multimeter Users Manual 6 Autoranging The meter defa ults to autor ange w hen you tur n it on. I n autora nge, the m eter selec ts the range autom atic ally. Manually Selecting a Range The meter als o has a m anual ran ge mode. In m anual rang e, you s elect and lock the meter in a ran ge.
12 Multimeter MEASURI NG VOLTAGE 7 MEASURING VOLTAGE 1. Inser t the test l eads i n the ja cks. 2. To select a voltage function, pu t the s lide-s witch in t he middle position. Se e Figure 3. To toggle betw een dc and ac, pr ess [ g ]. 3. Touch the probes to th e test po ints, and r ead the display .
12 Multimeter Users Manual 8 Figure 3. Measuring Vo ltage.
12 Multimeter TESTI NG CONTINUITY A ND MEAS URI NG RESISTANCE 9 TESTING CONTINUITY AND M EASURING RESISTANC E 1. Inser t the test l eads i n the ja cks, and turn off power t o the circ uit under test. External volt age ac ross the c omponents c auses inv alid readin gs.
12 Multimeter Users Manual 10 Figure 4. Continuity and Res istance Measurements.
12 Multimeter TESTING DIOD ES 11 TESTING DIOD ES 1. Inser t the test l eads i n the ja cks. 2. Put the slide-switch i n the c ontinuity/o hms pos ition. The m eter selec ts eit her the continuity /diode ( R G ) or ohm s ( e ) f unction. If ohms is select ed, pres s [ g ] to toggle to th e conti nuity/diode functi on.
12 Multimeter Users Manual 12 Figure 5. Test ing Diodes.
12 Multimeter VCHEK A N D HOW TO USE IT 13 VCHEK AND HO W TO USE IT i is a subs et of the con tinuity /ohms func tion. In i , th e meter is designed t o automatical ly display an ac or dc volt age when the meter detec ts a vo ltage gre ater in magnitude th an about 4.
12 Multimeter Users Manual 14 Use i only on power s uppli es and other power sourc es that hav e a low output impedance. D o not us e i to m easure volt age in e lectronic c ircuitry u nless a 2 k e load will not damage the circ uit. See † on pag e 27.
12 Multimeter MEAS URI NG CAPACITANCE 15 MEASURING CAPACITA NCE First, turn off p ower to the circuit, a nd dis connect and discharge the ca pacitor. 1. Insert test leads, an d move the slide-sw itch to [ E ]. (See Figure 6 .) 2. Press [ E ]. The capac itance func tion is select ed and µF is dis played .
12 Multimeter Users Manual 16 Figure 6. Measuring Capacitance.
12 Multimeter USING MIN MAX FUNCTIO NS 17 USING MIN MAX FUNCTION S Recording Minimum and Maximum Readings MIN MAX rec ords the highes t and lowes t measurem ents taken. MIN M AX cannot be used when the meter is measuring capacita nce. In t he MIN M AX mode, autora nging, Standby, and i are dis able d.
12 Multimeter Users Manual 18 Figure 7. Displaying Minimum and Maximum Reading.
12 Multimeter USING MIN MAX FUNCTIO NS 19 Recording Minimum and Maximum Reading with Elapsed Time The MIN MAX w ith elapsed-t ime mode r ecords the t ime (in hours and m inutes) between when M IN MAX was entered and the last high a nd low w as recorded .
12 Multimeter Users Manual 20 Figure 8. Maximum and Minimum Reading with Elapsed Time.
12 Multimeter USING MIN MAX FUNCTIO NS 21 Capturing Continuity Intermittents with Continuity Capture When testing c ontin uity, the m eter can cap ture intermittents as short as 250 µs, and display them as open-t o-short a nd short-to-op en trans itions .
12 Multimeter Users Manual 22 Figur e 9. Open-to-Sh o r t and Sho r t-to -Op en Tran siti ons.
12 Multimeter TURNING BEE PER OFF 23 TURNING BEEPER OFF To disable a ll beep er func tions, pr ess and ho ld dow n [ Z ] for 2 second s whil e tu r ning the meter on. MAINTENANCE W Warning To avoid el ectrical sho ck or damag e to the m eter, do not g et water in side the case.
12 Multimeter Users Manual 24 Service and P arts This meter s hould be s erviced on ly by a qualified s ervice tec hnic ian. To order t he servic e manual (PN 900824) and oth er parts or for servic e inform ation, in th e USA call 1-800-825-9810. Outside t he USA, c ontact the neares t Fluke serv ice c enter.
12 Multimeter SPECIF ICA TION S 25 Maximum Voltage Between any Terminal and Earth Ground 600 V rms Display 3 3/ 4-digits, 4000 counts , updates 4/sec Operating Temperature -10 °C to 50 °C Storage Temperature -30 °C to 60 °C indefinitely (to -40 °C for 100 hrs) Temperature Coefficient 0.
12 Multimeter Users Manual 26 Functi on Range Resolu tion Accur acy (50 to 4 00 Hz) 4000 mV* 1 mV ±(1.9 %+3) 4.000 V 0.001 V ±(1.9 %+3) 40.00 V 0.01 V ±(1.9 %+3) 400.0 V 0.1 V ±(1.9 %+3) 600 V 1 V ±(1.9 %+3) 4000 mV* 1 mV ±(0.9 %+2) 4.000 V 0.001 V ±(0.
12 Multimeter SPECIF ICA TION S 27 Functi on Overl oad Prote ction* Input Impe danc e (Nomi nal) Comm o n Mo de Rejection Ratio (1 k Ω Unbalan ce) Norma l Mode Rejection 600 V dc >10 M Ω < 1.
12 Multimeter Users Manual 28.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Fluke PN 2063508 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Fluke PN 2063508 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Fluke PN 2063508 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Fluke PN 2063508 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Fluke PN 2063508, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Fluke PN 2063508.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Fluke PN 2063508. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Fluke PN 2063508 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.