Manuale d’uso / di manutenzione del prodotto DS601IV2 del fabbricante Fisher & Paykel
Vai alla pagina of 45
DishDrawer Models DD601v2 DD601Iv2 DS601v2 DS601Iv2 599039.
- i - Contents 1.0 SERVICE REQUIREMENTS 1 1.1 Health & Safety 1 1.2 Specialised Tools 3 2.0 DIMENSIONS & SPECIFICATIONS 4 3.0 TECHNICAL OVERVIEW 5 3.1 Electronics 5 3.2 Motor 5 3.3 Cabinet 5 3.4 Filling 6 3.5 Dispensing Detergent 7 3.6 Lid Seal 7 3.
- ii - 6.0 SERVICE PROCEDURES 34 6.1 Drawer Front Removal 34 6.2 Handle and LCD Display Removal 34 6.3 Drying Fan Removal 34 6.4 Detergent Dispenser 35 6.5 Electronic Controller 35 6.6 Top Kick Strip Removal 35 6.7 Lower Kick Strip Removal 36 6.8 Wiring Cover Removal 36 6.
- 1 - 1.0 SERVICE REQUIREMENTS 1.1 Health & Safety Note: When servicing the dishdrawer, health and safety issues must be considered at all times. Specific safety issues are listed below with their appropriate icon. These are illustrated throughout the service information to remind service people of the issues.
- 2 - 1.1.6 Insulation Test Megger test to check insulation. Warn ing: Short together the phase and neutral pins on the plug so as not to damage any electronic circuitry. 1.1.7 Solvent and Excessive Heat Damage Plastic surfaces can be damaged by solvents and excessive heat.
- 3 - 1.2 Specialised Tools For servicing this product Specialised tools are required. 1.2.1 Static Strap: To be used as ESD protection when replacing or handling electronic components. 1.2.2 Down Load Pen Connection: P/N 425930C. To be used to retrieve data from the electronic controller along with the diagnostic program on your laptop.
- 4 - 2.0 DIMENSIONS & SPECIFICATIONS Product Size (mm) Minimum Cavity Size Height 817-877mm 820-880mm Width 595mm 600mm Depth 570mm 580mm Drawer Open (incl cab) 1080mm Electrical 230-240V AC 50Hz 10amp max.
- 5 - 3.0 TECHNICAL OVERVIEW 3.1 Electronics The DD601 electronic controller has two separate micro controllers on the main printed circuit board. One is for motor control and output switching and the other is for controlling interface and console functions.
- 6 - The tub extends 510mm out of the cabinet by travelling along two rigidly attached slides on either side of the tub. 3.3.2 Drawer Fronts Prefinished drawer fronts are formed from a prepainted blank of steel. The drawer fronts are attached to the tub by means of formed hooks and two pins which are inserted through either side of the tub.
- 7 - 3.5 Dispensing Detergent The dispenser is mounted in the front wall of the wash tub. The detergent dispenser consists of two detergent chambers, one for pre wash and the other for the main wash.
- 8 - 3.7 Wash Cycle 3.7.1 Tub The tub is the main cavity where all the wash activity occurs. The tub is a plastic recepticle which has a wash pump and sprayarm at the base. The tub also has guide vanes around its walls which direct falling water from the wash cycle in a clockwise direction around the filter plate.
- 9 - 3.8.4 Overheating Control The heater plate is only activated during the wash cycles. It is not used for drying. The temperature is maintained by the thermistor. The element circuit is continuously monitored by the electronic controller and will switch a fail safe relay if a fault is detected in the heater circuit.
- 10 - 3.11 Drying Cycle Immediately after water from the final hot rinse has been drained from the tub, the drying system begins operation. The fan draws air through the tub, where it absorbs water from the dishload.
- 11 - 3.14 Wiring Cover The wiring cover protects the customer from the 240V mains supply which passes over the link assembly and under the lockring to the front of the tub. It also serves to protect the motor assembly, drain and fill hoses from damage when opening and closing drawers.
- 12 - 4.0 DIAGNOSTICS 4.1 Setup & Diagnostics The DishDrawer comes with comprehensive fault codes and built in diagnostics, to save the user & service person time and worry, if the dishwasher ever exhibits a fault. 4.2 Fault Modes The faults are displayed in the LCD as one of 8 F (fatal) faults or one of 3 U (user) faults.
- 13 - 4.3 Diagnostic Modes 4.3.1 Temperature Display Mode During a wash cycle, the current water temperature can be displayed on the LCD instead of the time remaining. To enter temperature display mode, start a wash cycle as normal. Initiate a keylock by pushing and holding the Keylock button for 4 seconds.
- 14 - 4.3.5. Water Pressure Set Up The DishDrawer can be set to either High(Standard) or Low inlet water pressure. The LCD displays the current water pressure setting. If “HP” is displayed then the setting is High Pressure. If “ LP ” is displayed then the setting is Low Pressure.
- 15 - 4.3.9 Clearing Fault Logs To Clear the current Fault press the Keylock button until a beep is sounded. This action moves the Current Fault into the Previous Fault while clearing the Current Fault. To Clear the Previous Fault press Keylock once more until the beep is sounded.
- 16 - LCD Heavy Norm Fast Deli Hardware Output ------------------------------------------------------------------------------------------- EU Off Off Off On Exhaust Valve FU Off Off On Off Fill Water.
- 17 - Cycle Count Retrieval To display the cycle count on the LCD screen, Pause the dishwasher while running a Continuous Cycle. The two bytes of the cycle count will be displayed alternately, in syncronisation with the changing backlight. The Low byte is displayed when the backlight is Green.
- 18 - 4.4 Diagnostics Quick Reference Flow Cha rt To clear the current fault code press the Keylock once. Note if you press Keylock again you will remove the previous fault.
- 19 - 4.4 Diagnostics Quick Reference Flow Chart cont'd Press Power Button Press Start/Pause button Stand - by mode LCD is Rd backlight and displays CC. Touchswitch panel is Red Red Red Red Select desired cycle and operate as normal. Continuous cycle is indicated by backlight alternating between green & orange.
- 20 - 4.5 Fault Codes Fault Code LED Display Fault Possible Causes F1 ----# The flood switch has been activated. • A leak has occurred in the base of the dishwasher. • The fill valve has failed open. • The flood switch is faulty. • Excessive water has been added to a wash sub cycle, indicating leaking seal or siphoning.
- 21 - Fault Code LED Display Fault Possible Causes U1 #---# Fill fault. The motor has not primed after a given time. • The water supply is not turned on. • The machine is siphoning. • The sprayarm is not in place. • Excessive foaming. • The fill valve has failed closed.
- 22 - F1 Monitored while mains power is on. When one drawer leaks this cuts out both drawers. F1 is not monitored in diagnostics. Did a flood occur & activate the flood switch? Check the flood sw.
- 23 - F2 This fault is monitored when the motor is running. It is looking for 10 stalls in a row. It is not monitored during diagnostics. The rotor has not been sensed as rotating. Is the rotor jammed? Note* Free or replace the rotor. Check the rotor housing.
- 24 - F3 This fault is monitored every 6 seconds while the mains power is connected. It is not monitored during diagnostics. Water sensed at greater than 80°C Adjust the incoming water temperature I.
- 25 - F4 No temperature increase has been sensed while the element is on. Does the element heat in diagnostics? Test the resistance of the element at the controller as per the specifications Test the resistance of the sensor as per the temperature chart Turn the power to the dishdrawer off at the supply.
- 26 - F6 Inter-communication fault. Replace the electronic controller. If this occurs while you are servicing the Dishdrawer, you may have induced the fault , so ignore it.
- 27 - U1 Motor runs for 15 seconds, during which time the fill valve operates for 2 seconds. This occurs three times. If prime is not detected then the fill valve is operated continually until prime is reached.
- 28 - U2 The tub drawer has been sensed as open during the cycle or the exhaust valve is open circuit. Is the drawer open? Shut the drawer. Check the microswitch is working in diagnostics. Check the mechanical operation of the the slides. Replace the microswitch.
- 29 - U3 Has the dishdrawer drained? Check the rotor/sprayarm are turning freely Check for pump blockage or drain impellor failure Possibilty of electronics incorrectly sensing the load but not likel.
- 30 - Poor Dry Performance Rinse aid not being dispensed Check the continuity of the wiring and pump solenoid by removing the connections at the PCB and testing with a meter. Is there rinse aid in the dispesner? Check the voltage (24 Volts dc) at the PCB.
- 31 - Detergent not flushing out of Pre Wash or Main Wash chambers In Diagnostics active the fill valve and note which side of the dispenser the water comes out. Then turn off the fill valve and activate the diverter valve(dd), re-active the fill valve to see if the water now exits the other side of the dispenser.
- 32 - Fit test gauge to Air pump Enter Diagnostics and activate Exhaust valve then air pump Run pump for 60 seconds. Pressure must reach between 30 - 40 Kpa. Switch Pump off Pinch plumbing above the exhaust valve connection. Pressure creases? Pinch plumbing above the test gauge connection.
- 33 - 5.0 WIRING DIAGRAM.
- 34 - 6.0 SERVICE PROCEDU RES 6.1. Drawer Front Removal 6.1.1 Slide open drawer. 6.1.2 Locate draw pin on either side of the tub. 6.1.3 Using a sharp pair of long nose pliers or slip jaw pliers grasp the center dividing web of the pin and pull away from the tub to remove the pin.
- 35 - 6.4 Detergent Dispenser 6.4.1 Remove the drawer front and handle as per instructions in 6.1.& 6.2 6.4.2 Disconnect the two wiring loom connections off the dispenser coils.
- 36 - 6.7 Lower Kick Strip Removal 6.7.1 Remove the top kick strip as per instructions in 6.6. 6.7.2 Insert a flat blade screwdriver into the two inserts in the trim above the lower kick strip and twist. 6.7.3 This will unclip the lower kick strip from the chassis.
- 37 - 6.11 Tub Removal 6.11.1 Remove the drawer front as per instructions in 6.1. 6.11.2 Remove the wiring cover as per instructions in 6.8. 6.11.3 Disconnect the fill hose from the dispenser (water may drip) 6.11.4 Disconnect the mains harness and chassis harness connectors from the electronic controller.
- 38 - 6.13 Lid Assembly Removal 6.13.1 Remove tub assembly as per instructions in 6.11 6.13.2 Disconnect the lid plumbing off the exhaust valve and air pump above the ‘ Y ’ joint. 6.13.3 Release two locking tabs securing the front of the lid to the chassis.
- 39 - 6.15 Slide Runner Replacement 6.15.1 Remove the Tub as per instructions 6.11 6.15.2 Bottom slide runners only. Remove the two large Philips head screws securing the slide runner at the front. The backing plate that the screws locate into may come loose.
- 40 - 6.18 Link Assembly Removal 6.18.1 Remove tub as in instructions 6.11. 6.18.2 Release clips on side of link assembly to allow the lid of the assembly to hinge open. 6.18.3 Using a blade screw driver to wedge out the spigots in the hinge point of the bracket connecting to the rear of the dishwasher.
- 41 - 6.20 Exhaust Valve Removal Note: This component maybe serviced by two Methods. 6.20.1 Method 1: Remove tub assembly as per instructions in 6.11. 6.20.2 Method 2: Remove lower kick strip as per instructions in 6.7. 6.20.3 Remove the clip pegs from the slide retainers.
- 42 - 6.23 EMI Filter Removal 6.23.1 Remove the lower tub as per instructions in 6.11. 6.23.2 The EMI filter is located at the rear left hand side of the chassis base. 6.23.3 Remove the screw in the rear access panel of the chassis.. 6.23.4 Raise the insulating cover to expose the EMI filter.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Fisher & Paykel DS601IV2 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Fisher & Paykel DS601IV2 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Fisher & Paykel DS601IV2 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Fisher & Paykel DS601IV2 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Fisher & Paykel DS601IV2, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Fisher & Paykel DS601IV2.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Fisher & Paykel DS601IV2. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Fisher & Paykel DS601IV2 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.