Manuale d’uso / di manutenzione del prodotto CM6200 del fabbricante Firstech, LLC.
Vai alla pagina of 33
Please visit www .firstechonline.com for additional installation resources MODEL : RF-2W900FM-5PT F irstech, LLC. 21911 68th Ave S. Kent, W A 98032 Phone.
Copyright 2009 F irstech, LLC. P age 2 CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com T able of Contents CM6200 Introduction 4 Kit Contents 4 Installation Basics 5 R.
Copyright 2009 F irstech, LLC. P age 3 CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com.
CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 4 Introduction CM6200 Kit Contents CM6200 All Firstech FT -6200S CONT controllers.
CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 5 If you are new to installing Firstech Series Remote Starts and / or Alarms, we highly recommended that you thoroughly review this manual to installing your rst unit.
CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 6 R emote Programming Routine CM6200 IMPOR T ANT : Any and all remotes must be coded to the control module prior to performing any and all opera- tions.
CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 7 Placement and Use of Components CM6200 IMPOR T ANT : The placement and use of components are critical to the performance of this system.
Copyright 2009 F irstech, LLC. P age 8 CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com Common Procedures CM6200 Jumper Settings Caution: Jumper settings affect the polarity and use of certain outputs. If these jumpers are used incorrectly , damage to the vehicle and /or control module may occur .
Copyright 2009 F irstech, LLC. P age 9 CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com STEP 1: Start the vehicle with the key . Allow time for the engine to idle down. STEP 2: T est wire and make connection. At idle the tach wire should test between 1 to 4 V olts AC.
CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 10 Timed Crank Setting – Automatic T ransmission Only Option 2-10 setting 4 provides a timed 1.5 second crank for the remote start sequence.
CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 11 Additional Notes Reservation mode will be cancelled if the control module recognizes the vehicles door , hood or trunk opening – or if the alarm is triggered.
Copyright 2009 F irstech, LLC. P age 12 CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com W iring Descriptions CM6200 Connector 1 (CN1), 6-Pin Pin 1 White – Accessory 12V positive (+) output. This wire must be connected to the vehicle accessory / HV AC blower motor wire.
Copyright 2009 F irstech, LLC. P age 13 CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com IMPOR T ANT : For anti-grind and starter-kill applications, the yellow wire goes to the starter side of the vehicles starter wire and the yellow/black goes to the key side.
CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 14 Connector 3 (CN2), 20-Pin: Pr ogrammable Output Connector (POC) IMPOR T ANT : Odd Pin numbers 1 through 17 are programmable for up to 12 different output types.
CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 15 Pin 1 1 Black [ POC 5] – Sta tus/G round while runni ng 250 mA negativ e (-) outpu t.
Copyright 2009 F irstech, LLC. P age 16 CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com Pin 18 Gray/Black – Hood Pin negative (-) input.
Copyright 2009 F irstech, LLC. P age 17 CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com Connector 5 (CN5), 4-Pin (RS 232 Data Port) This connector is used for updating control modules via www .rstechonline.com. Y ou must also use this port to ash Blade bypass modules.
Copyright 2009 F irstech, LLC. P age 18 Connector 10 (CN10), 2-Pin (Pr e-wired LED) Note: Do not mistake for Thermister port. Pin 1 Black - L.E.D negative (-) ground. Pin 2 Black/White- L.E.D. 3V positive (+) output. Connector 1 1 (CN1 1), 3-Pin (Pre-wir ed V alet/Programming Switch) Pin 1 Gray/Black - Negative (-) ground.
Copyright 2009 F irstech, LLC. P age 19 CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com Option Group 2 Feature Default Setting - I Optional Setting - II Optional Sett.
CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 20 Option Group 3 Continued Feature Default Setting - I Optional Setting - II Opt.
CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 21 Special Option Group 1 Feature Setting V alue (Seconds) 1 Diesel T imer - DISL.
Copyright 2009 F irstech, LLC. P age 22 CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com 1-04 Double Pulse Unlock - If enabled, this option will cause the system to double pulse the unlock output. This option is used on a majority of T oyota vehicles.
Copyright 2009 F irstech, LLC. P age 23 CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com 2-01 T ach Sensing Method – This option will adjust the method at which tach is read by the module. At de fault this option will minimize overcrank during remote start.
2-09 T emperature of Ho t Startin g – W orks in conjun ction wit h Options 2-05 and 2- 06. See t he option table for available temperatures. 2-10 Engine Sensing – Review the “Common Procedures” section for complete explanations on the four engine sensing modes.
Copyright 2009 F irstech, LLC. P age 25 CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com 3-09 Horn Output When Alarm is T riggered - This changes the behavior of the white horn wire when the alarm is triggered. W ith this setting you can change the wire to a constant (-) negative output for an ad ditional siren.
Copyright 2009 F irstech, LLC. P age 26 CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com 4-05 Secure Aux Output – On the default setting, button 4 on the remote must be pressed rst before Aux 1 or Aux 2 can be triggered.
Copyright 2009 F irstech, LLC. P age 27 CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com 4-13 Antenna Power Save - Some people may not drive their vehicle very often, this may cause the battery to become discharged because it is not getting rechar ged on a regular basis.
Copyright 2009 F irstech, LLC. P age 28 CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com Option Programming CM6200 Option Programming Using the OP500 (pr ogrammer) The OP500 can be used to program any available option.
Copyright 2009 F irstech, LLC. P age 29 CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com How to Program Options with 2-W ay Remotes With 2 W ay Remotes (W ait for chir.
CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 30 T roubleshooting CM6200 Remote Start Error Codes If the remote start fails to start the vehicle, the parking lights will ash two times immediately .
CM6200 Install Guide Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 31 Frequently Ask ed Questions CM6200 I have everything hooked up and the system will not respond. A: The remotes need to be programmed.
The vehicle starts and shuts down 3 times in a row . A: This usually means that the engine sensing mode is not working correctly . If you are using a coil, change to an injector or try alternator mode. The vehicle will lock and unlock, but will not remote start or ash the parking lights.
Firstech technical support is reserved for authorized dealers only . Monday - Friday: 888-820-3690 (8:00 am – 5:00 pm Pacic Coast T ime) Email: support@compustar .com W eb: Register at: www .rstechonline.com click on “Authorized T ech” W ire Diagrams Click on the “Installogy Access Client” link found on your desktop.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Firstech, LLC. CM6200 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Firstech, LLC. CM6200 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Firstech, LLC. CM6200 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Firstech, LLC. CM6200 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Firstech, LLC. CM6200, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Firstech, LLC. CM6200.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Firstech, LLC. CM6200. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Firstech, LLC. CM6200 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.