Indice dei contenuti 41 sezioni Residential & Light Commercial HVAC · CH10 High Efficiency Series CH10 High Efficiency Series · 10 SEER Remote Heat Pump Units · PERFORMANCE: · … MostraNascondi
Page 1 of the Fedders CH1060CBD3VF user manual — Rated in accordance with D.O.E. test standards
Pagina 1 · clicca per ingrandire
Pagina 1

Residential & Light Commercial HVAC

Fedders CH1060CBD3VF — Residential & Light Commercial HVAC diagram (page 1)
Fig. 1 · Residential & Light Commercial HVAC

CH10 High Efficiency Series CH10 High Efficiency Series

10 SEER Remote Heat Pump Units

PERFORMANCE:

Efficiency rating of 10.0 SEER

Cooling and heating capacities from 1 1 ⁄ 2 to 5 tons

Fedders CH1060CBD3VF — PERFORMANCE: diagram (page 1)
Fig. 2

Rated in accordance with D.O.E. test standards

FEATURES:

Quiet, top air discharge

G-90 galvanized steel exterior cabinet with 1000-hour salt spray, powder-coated finish

Long-life copper tubes, aluminum fin refrigerant coils

State-of-the-art compressors

Powder-coated fan guard

Full louvered panel to protect coil

Large wrap-around coil surface

Control box located for easy access to electrical controls

Formed base with 2 1 ⁄ 2 ” ground clearance

Factory-installed liquid line filter dryer

WARRANTY:

Limited 10-year warranty on compressor

Limited 5-year warranty on all parts

Page 2 of the Fedders CH1060CBD3VF user manual — FOOTNOTES:
Pagina 2 · clicca per ingrandire
Pagina 2

CH10 H igh E fficiency S eries

MODEL SPECIFICATIONS MODEL NUMBERCH1018BBD1VFCH1024BBD1VFCH1030BDD1VFCH1036BBD1VFCH1036BBD3VFCH1036BBD4VF PERFORMANCE DATA NOMINAL COOLING BTU/H17 60022 60028 20034 000 NOMINAL HEATING BTU/H17 60022 00027 00034 400 SEER (COOLING) BTU/H-W10.010.010.010.0 CFM60080010001250 VOLTS/HZ/PHASE208-230/60/1208-230/60/1208-230/60/1208-230/60/1208-230/60/3460/60/3 VOLTAGE RANGE197-253197-253197-253197-253187-253415-508 OPERATING CURRENT AMPS ①9.212.015.418.013.26.2 MIN. WIRE AMPACITY11.314.718.022.416.515.0 MAX. HACR BREAKER ➁152530352515 COMPRESSOR DATA RLA8.89.811.415.211.44.8 LRA496075967540 FAN DATA DIAMETER18 INCH / 3 BLADE18 INCH / 3 BLADE18 INCH / 3 BLADE18 INCH / 4 BLADE MOTOR TYPEPSCPSCPSCPSC HP (W) / FLA1/6 / 1.01/6 / 1.01/6 / 1.01/5 / 1.81/4 / 1.2 RPM1075107510751075 CFM1800180018002400 OUTDOOR COIL TYPEENHANCED ALUMINUM PLATE FIN / RIFLED COPPER TUBE FACE AREA9.89.89.812.0 O.D. / F.P.I.-ROWS5/16 / 18-13/8 / 18-13/8 / 18-13/8 / 18-1 REFRIGERANT LINE CONNECTIONS(SERVICE VALVE PORT I.D.) LIQUID3/8 ID VAPOR3/4 ID3/4 ID3/4 ID3/4 ID WEIGHTS NET WEIGHT — lbs.137140142161 SHIPPING WEIGHT — lbs.143149151169
COOLING PERFORMANCE DATA MATCHED SYSTEM OUTDOOR UNIT MODEL*EVAPORATOR COIL➂RATINGS AT STANDARD CONDITIONSCOOLING DATA AT EXTENDED OUTDOOR AMBIENTS °F.M.B.T.U.H. BTUHSEERCFM80859095100105110115 CH1018BBDE3009A1760010600TOTAL18 70018 30017 90017 60016 70015 80014 80013 900 SENSIBLE13 50013 20012 90012 70012 02011 40010 70010 000 CH1024BBDE3009A2260010800TOTAL24 50023 90023 20022 60021 40020 20019 00017 900 SENSIBLE17 60017 20016 70016 30015 40014 50013 70012 900 CH1030BBDE3612A28200101000TOTAL29 80029 30028 70028 20026 60025 00023 50021 900 SENSIBLE21 50021 10020 70020 30019 10018 00016 90015 800 CH1036BBDE3618A34000101250TOTAL37 30036 40035 50034 60031 90028 80025 90023 000 SENSIBLE26 90028 40025 60024 90023 00020 70018 60016 600 CH1042CBDE6016A39500101350TOTAL42 40041 80041 10039 50038 90037 30035 80034 200 SENSIBLE30 60030 10029 60028 40028 00026 90025 80024 600 CH1048CBDE6026A46000101700TOTAL49 70048 50047 30046 00044 40043 00041 50039 800 SENSIBLE35 80034 90034 00033 10032 00031 00029 90028 600 CH1060CBDE6037A55500101850TOTAL59 20057 90056 70055 50054 00052 60051 10049 700 SENSIBLE42 60041 70040 80040 00038 90037 90036 80035 800

*Basic model number only. See unit nomenclature on the last page for exact model number.

FOOTNOTES:

➀ Amps at 104˚F OD temp. 80˚F DB / 67˚F WB indoor temp. ➁ Time delay type fuse for HACR Circuit Breaker. ➂ For indoor coils nomenclature see indoor coil specification sheet. ➃ Air handler includes evaporator coil.

Page 3 of the Fedders CH1060CBD3VF user manual — Residential & Light Commercial – 10 SEER Remote Heat Pump Units
Pagina 3 · clicca per ingrandire
Pagina 3
MODEL SPECIFICATIONS MODEL NUMBERCH1042CBD1VFCH1048CBD1VFCH1048CBD3VFCH1048CBD4VFCH1060CBD1VFCH1060CBD3VFCH1060CBD4VF PERFORMANCE DATA NOMINAL COOLING BTU/H39 50046 00055 500 NOMINAL HEATING BTU/H39 50047 00054 000 SEER (COOLING) BTU/H-W10.010.010.0 CFM135017001850 VOLTS/HZ/PHASE208-230/60/1208-230/60/1208-230/60/3460/60/3208-230/60/1208-230/60/3460/60/3 VOLTAGE RANGE197-253197-253187-253415-508197-253187-253415-508 OPERATING CURRENT AMPS ①20.026.216.56.430.219.49.4 MIN. WIRE AMPACITY24.031.020.011.038.024.012.0 MAX. HACR BREAKER ➁40503015604020 COMPRESSOR DATA RLA17.823.014.37.228.017.28.2 LRA103131914615012460 FAN DATA DIAMETER22 INCH / 3 BLADE22 INCH / 3 BLADE22 INCH / 3 BLADE MOTOR TYPEPSCPSCPSC HP (W) / FLA1/4 / 2.21/4 / 2.21/4 / 1.21/4 / 2.21/4 / 1.2 RPM107510751075 CFM3 4003 4003 400 OUTDOOR COIL TYPEENHANCED ALUMINUM PLATE FIN / RIFLED COPPER TUBE FACE AREA14.718.322.0 O.D. / F.P.I.-ROWS3/8 / 18-13/8 / 18-13/8 / 18-1 REFRIGERANT LINE CONNECTIONS(SERVICE VALVE PORT I.D.) LIQUID3/8 ID3/8 ID3/8 ID VAPOR3/4 ID7/8 ID7/8 ID WEIGHTS NET WEIGHT — lbs.172190214 SHIPPING WEIGHT — lbs.180199224
HEATING PERFORMANCE DATA MATCHED SYSTEM OUTDOOR UNIT MODEL*AIR HANDLER➃RATINGS AT STANDARD CONDITIONSHEATING DATA AT EXTENDED OUTDOOR AMBIENTS °F.M.B.T.U.H. BTUHHSPFCFM-100102030405060 CH1018BBDA24B1176007.26003 5005 7007 90010 10013 40015 30018 80022 400 CH1024BBDA24B1220007.28008 1009 30010 40011 50012 70017 20025 20033 100 CH1030BBDA30B1270007.2100011 10012 90014 70016 50018 30023 60032 30041 000 CH1036BBDA36B1344007.2125012 80015 00017 30019 50021 70028 30039 30050 200 CH1042CBDA48B1395007.2135019 90021 80023 60025 60027 40033 40043 80053 600 CH1048CBDA48B2470007.2170023 80026 00028 10030 30032 50039 19050 30061 500 CH1060CBDA60B1540007.2185030 40032 90035 40037 80040 30047 50059 60071 700

Residential & Light Commercial – 10 SEER Remote Heat Pump Units

Page 4 of the Fedders CH1060CBD3VF user manual — F
Pagina 4 · clicca per ingrandire
Pagina 4
Fedders CH1060CBD3VF — A B diagram (page 4)
Fig. 3
CONDENSER DIMENSIONS (INCHES) MODELUNITSHIPPING ABCABC CH1018BVF211/2211/2261/2231/2231/227 CH1024BVF211/2211/2261/2231/2231/227 CH1030BVF211/2211/2261/2231/2231/227 CH1036BVF211/2211/2321/2231/2231/233 CH1042CVF291/2291/2261/2311/2311/227 CH1048CVF291/2291/2321/2311/2311/233 CH1060CVF291/2291/2381/2311/2311/239

A B

MODEL KEYResidential & Light Commercial – Outdoor Unit MODEL KEY: Air Handler

OUTDOOR HEAT PUMP

MODEL SERIES

MODEL REVISION

UNIT

UNIT EFFICIENCY

NOMINAL CAPACITY

CHASSIS

MODEL VERSION

BRAND

CH

B B X

D

A 24 B 1

OPTION LEVEL D = STANDARD UNIT R-22 E = STANDARD UNIT R-407 F = HIGH & LOW PRESSURE SWITCH

V = VALVE SWEAT TYPE FITTING

1 = 230/208 VOLT, 1 PHASE, 60 Hz 2 = 220/240 VOLT, 1 PHASE, 50 Hz 3 = 230/208 VOLT, 3 PHASE, 60 Hz 4 = 460 VOLT, 3 PHASE, 60 Hz 5 = 230 VOLT, 3 PHASE, 50 Hz 6 = 380 VOLT, 3 PHASE, 50 Hz

NOMINAL

EVAPORATOR DESIGNATION

BTU/H

R

T

F

E

D

T

O

E

R

E

A

A

R

A

S

T

U

R

T

A

R

Y

R

O

N

D

O

M

U

F

A

U

N

T

O

N

N

P

Y

M

A

N

E

R

T

G

N

G

Rated in Accordance with ARI Standard 210/240. Certification Applies Only When Used with Proper Components as Listed with ARI.

A

R

E

R

T

Q

U

P

M

E

N

N

S

O

F

Fedders Unitary Products 505 Martinsville Rd. Liberty Corner, NJ 07938 (908) 604-8686 Form No. F-CH10-0804

F

S

T

A

A

T

N

O

N

D

S

A

E

R

T

D

O

All product specifications reflect available information at the printing of this brochure. Fedders reserves the right to revise or modify products and/or specifications without notice. ©2004 Fedders Unitary Products. Fedders is a registered trademark of Fedders North America, Inc.

• · •

Fai una domanda su Fedders CH1060CBD3VF

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Fedders CH1060CBD3VF

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Fedders CH1060CBD3VF manuale in PDF

4 pagine·70 KB·Pompa di calore·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…