Instruction Manual READ AND SA VE THESE INSTRUCTIONS The Installer must leave these instructions with the homeowner . The homeowner must keep these instructions for future reference and for local electrical inspectors’ use.
2 EN CONTENTS WARNING 3 CHARACTERISTICS 5 INST ALLA TION 8 USE 13 MAINTENANCE 1 4.
3 EN READ THESE INSTRUCTIONS BEFORE YOU ST ART INST ALLING THIS RANGEHOOD READ AND SA VE THESE INSTRUCTIONS W ARNING: - T O REDUCE THE RISK OF A RANGE T OP GREASE FIRE : Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite.
4 EN This appliance should be connected directly to the fused disconnect (or circuit breaker) through flexible, armored or nonmetallic sheathed copper cable.
5 EN 1 3 4 5 10 11 12 13 G E F D C A 2 CHARACTERISTICS Components Q.ty 1 1 Hood Body , complete with: Blower, Filters, Controls 2 1 Built-in hood body case 3 1 Rear remote motor connection panel 4 1 T.
6 EN Dimensional chart - Hood Distance from the Hob.
7 EN Dimensional chart - LIGHT.
8 EN INST ALLA TION The hood can be installed in the following ways: top air outlet, bottom air outlet, rear air outlet. Once the desired configuration has been chosen (see the diagrams below) it will be necessary to provide an opening in the wall where to house the built-in hood body case.
9 EN LIGHTING UNIT INST ALLA TION SCHEME LIGHTING UNIT LOWER BORDER SHALL BE INST ALLED A T THE MINIMUM DIST ANCE OF 34 9/16 IN. ABOVE THE COOKING SURF ACE.
10 EN REAR AIR OUTLET CONFIGURA TION • Remove the suction panel by unfastening the 8 screws around the frame. • Remove the metal grease filters. • Remove the metal profile fixed to the flange by unfastening the 5 screws. • Fit the air outlet plug into the top air outlet.
11 EN Hood body installation • In case of the bottom air outlet configuration the hood body has to be turned 180°. • Remove the top cover of the terminal box by unfastening the two screws fixing it to the hood casing.
12 EN Lighting unit installation • Provide for passage of the electrical connection wires with the hood body . • Slide the top cover downwards, unfastening the two side screws and taking care not to scratch the tubular support members. • Insert the 4 plugs D into the earlier drilled holes.
13 EN Electrical connection ELECTRICAL SHOCK HAZARD • Disconnect power before making electrical connctions. • Connect ground wire to green ground screw in terminal box.
14 EN MAINTENANCE Grease filters CLEANING MET AL GREASE FIL TERS • Alarm signal reset • Switch off the lights and extractor motor . • Press button T3 for at least 3 seconds, until the leds start to flash. Cleaning the filters • Open the suction cover using the lever provided.
15 EN Electric Diagram Lighting LIGHT REPLACEMENT 20 W halogen light. • Extract the lamp from the Support. • Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes.
436002499_02 - 041 103.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Faber Remote Blower è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Faber Remote Blower - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Faber Remote Blower imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Faber Remote Blower ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Faber Remote Blower, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Faber Remote Blower.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Faber Remote Blower. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Faber Remote Blower insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.