506252-01 Page 1 of 13 Issue 0902 Save these instructions for future reference INST ALLA TION AND MAINTENANCE INSTRUCTIONS (2,4)PCE(13,15) SERIES Electric Cooling Package Unit If this unit is to be installed in a mobile or manufactured home application, the ductwork must be sized to achieve static pressures within the manufacturer ’ s guidelines.
Page 2 of 13 506252-01 Issue 0902 INST ALLA TION These instructions, and any instructions p ackaged with mating components and/or accessories, should be carefully read prior to beginning installation. Note p articularly any CAUTIONS or W ARNINGS in these instructions and all labels on the units .
506252-01 Page 3 of 13 Issue 0902 dimension across the unit must be used across the top of the unit. Recommended spreader length: 3 ton and smaller package unit s – 44", 3.5 ton and larger units – 54". Units may also be moved or lifted with a forklif t while still in the factory-supplied packaging.
Page 4 of 13 506252-01 Issue 0902 not be sized by matching the dimensions of the duct connections on the unit. Out door ductwork must be insulated and waterproofed.
506252-01 Page 5 of 13 Issue 0902 Power supply to the unit must comply with all applicable codes and the National Electical Code (NEC) or Canadian Electrical Code (CEC). A fused disconnect switch should be field provided for the unit. The switch must be sep arate from all other circuits.
Page 6 of 13 506252-01 Issue 0902 Compressor Units are shipped with compressor mountings factory- adjusted and ready for operation. Caution: Do not loosen compressor mounting bolts. Heater Kit Accessory (if used) The unit is fully equipped for cooling operation without auxiliary heat.
506252-01 Page 7 of 13 Issue 0902 OPERA TION Sequence of Operation Cooling Upon cooling demand, the thermostat closes circuit R and Y . Closing R and Y closes the unit contactor , starting the compressor and outdoor fan. The thermost at automatically closes R to G circuit which also brings on the indoor blower at the same time.
Page 8 of 13 506252-01 Issue 0902 Cooling System Performance For maximum performance of the cooling system, operating temperatures and pressure should be checked. Superheat should be determined at S tandard ARI test conditions of 82°F outdoor and 80°F indoor dry bulb/67°F wet bulb.
506252-01 Page 9 of 13 Issue 0902 Owner Record Model # _________________________________ Serial # _________________________________ Installation Date ___________________________ Installed by: Dealer _.
Page 10 of 13 506252-01 Issue 0902 Figure 8 Connection Diagram Single Phase – PSC Motor P/N 48396-001 Unit F actor y Shipped S ettin gs C ooling Input (B L K ) 24 LOW 30 MED 36 HIGH 42 LOW 48 MED 60.
506252-01 Page 11 of 13 Issue 0902 Figure 9 Connection Diagram Single Phase – V ariable S peed Motor P/N 48397-001 CONDENSER F AN MOT OR DIAGNOSTIC MODULE Unit F actor y Shipped Sett ings AD J US T .
Page 12 of 13 506252-01 Issue 0902 ALLIED AIR ENTERPRISES EQUIPMENT LIMITED W ARRANTY APPLIES IN U.S.A. AND CANADA ONL Y F AILURE TO MAINT AIN YOUR EQUIPMENT WILL VOID THIS W ARRANTY COVERED EQUIPMENT.
506252-01 Page 13 of 13 Issue 0902 Allied Air Enterprises Inc. (“Allied Air”) provides its air conditioning and heating product s with a S tandard Limited Parts Wa rranty for five (5) years. This additional 5-Y ear Limited Extended Parts Warranty is in addition to and is intended to supplement Allied Air ’ s S tandard Limited Parts Warranty .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Allied Air Enterprises 4)PCE(13 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Allied Air Enterprises 4)PCE(13 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Allied Air Enterprises 4)PCE(13 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Allied Air Enterprises 4)PCE(13 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Allied Air Enterprises 4)PCE(13, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Allied Air Enterprises 4)PCE(13.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Allied Air Enterprises 4)PCE(13. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Allied Air Enterprises 4)PCE(13 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.