MR. HEA TER, INC., 4 560 W . 1 60 TH ST ., CLEVEL AND, OHIO 44 1 3 5 · 2 1 6-9 1 6-3000 W ARNING: If the information in this manual is not followed exactly , a re or explosion may result causing property damage, personal injury , or loss of life.
2 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters This appliance may be installed in an aftermarket* permanently manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate.
3 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters 9. Operating heater above elevations of 4,500 feet could cause pilot/ODS to shutdown heater . 10. Always run heater with control knob in a locked po - sition. Never set control knob between locked posi - tions.
4 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters Product Features Figure 1 SAFETY DEVICE This heater has a pilot with an Oxygen Depletion Sen - sor (ODS) safety shut off system. The ODS/pilot shuts off the heater if there is not enough fresh air .
5 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters *Adjoining rooms are communication only if there are doorless passageways or ventilation grills be - tween them. DETERMINING THE TYPE OF HEA TER LOCA TION SP ACE: Use this method to determine if you have a conned or unconned space.
6 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters *A CSA/AGA certied equipment shutoff valve with 1/8” NPT tap is an acceptable alternative to test gauge connection. Purchase a CSA/AGA certied equipment shutoff valve from your dealer .
7 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters Figure 4 F ASTENING HEA TER TO W ALL Mounting Bracket The mounting bracket in located on the back panel of heater (see gure 5). It has been taped there for ship - ping.
8 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters 1. Drill holes at marked locations using 5/16” drill bit. For solid walls (concrete or masonry), drill at least 1” deep. 2. Fold wall anchor as shown in gure 8 below .
9 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters W ARNING: This appliance requires a 3/8” NPT (National Pipe Thread) inlet connection to the pressure regulator . Use of oor mounting feet will require you to use a 3/8 NPT street elbow to make gas connection.
10 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters Equipment Shutoff V alve Open Closed Figure 15 ELECTRICAL WIRING DIAGRAM: If any original wiring as supplied with the heater must be replaced, it must be replaced with type A WG 105 o C wire or its equivalent except as indicated.
11 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters 9. T o select the desired heat level, turn the temperature setting knob counterclockwise to between 1 & 5. THERMOST A T CONTROL OPERA TION FOR IR20LPT / IR30LPT : The thermostatic control used simply turns on and off the burner .
12 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters A yellow tip on the pilot ame indicates dust and dirt in the pilot assembly . T o clean the pilot assembly nd the small pilot air inlet hole about two inches from where the pilot ame comes out of the pilot assembly (see gure 25).
13 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters This page intentionally left blank..
14 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters OBSERVED SYMPT OM POSSIBLE CAUSE REMEDY When ignitor button is pressed in, there is no spark at pilot 1. Ignitor electrode positioned wrong. 2. Ignitor electrode is broken.
15 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters Burner does not light after ODS/pilot is lit 1. Burner orice is clogged 2. Burner orice diameter to small 3. Inlet gas pressure is too low 1. Clean burner orice (see Cleaning and Maintenance on page 1 1), or replace burner orice 2.
16 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters IR20LPT IR30LPT BF20LPT BF30LPT 7 2 36 39 38 35 16 21 16-1 16-2 6 26 29 24 22-3 13 23 18 3 11 1-2 1-4 22-2 3.
17 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters For all models, Equipment shutoff valve with 1/8” NPT tap. IR20LPT , IR30LPT , BF20LPT , BF30LPT , BF20LPT , BF30LPT • P ARTS LIST This list contains replacement parts used in your heater .
18 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters ITEM P ART NO. DESCRIPTION QTY . IR20LPT BF20LPT IR30LPT BF30LPT 37 – – – – – – 38 70677 – 706.
19 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters This page intentionally left blank..
20 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters Model # Start Serial# MHVFR2 0LPT 7 05 5 500 1 7 088 HSVFR2 0LPT 7 0 5 5 500 1 7 088 TSVFR2 0LPT 7 05 5 500 .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Enerco TSVFR30LPT è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Enerco TSVFR30LPT - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Enerco TSVFR30LPT imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Enerco TSVFR30LPT ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Enerco TSVFR30LPT, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Enerco TSVFR30LPT.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Enerco TSVFR30LPT. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Enerco TSVFR30LPT insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.