Manuale d’uso / di manutenzione del prodotto MHBF6LP del fabbricante Enerco
Vai alla pagina of 24
1 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater UNVENTED LP-GAS FIRED ROOM HEA TER Blue Flame Heaters Plaque Heaters Model # Burn Rate Model # Burn Rate MHB.
2 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater This appliance may be installed in an aftermarket* permanently manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate.
3 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater ings. Keep this manual for reference. It is your guide to safe and proper operation of this heater . Product Features Figure 1 SAFETY DEVICE This heater has a pilot with an Oxygen Depletion Sen - sor (ODS) safety shut off system.
4 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater The space in the above example is a conned space because the actual Btu/hr used is more than the maximum Btu/hr the space can support. Y ou must provide additional fresh air .
5 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater Figure 3. V entilation from Outdoors If necessary provide extra fresh air by using ventila - tion grills or ducts. Connect these items directly to the outdoors or spaces open to the outdoors.
6 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater Figure 4 F ASTENING HEA TER TO W ALL Mounting Bracket The mounting bracket in located on the back panel of heater (see gure 5). It has been taped there for ship - ping.
7 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater 1. Drill holes at marked locations using 5/16” drill bit. For solid walls (concrete or masonry), drill at least 1” deep. 2. Fold wall anchor as shown in gure 8 below .
8 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater (National Pipe Thread) inlet connection to the pressure regulator . Use of oor mounting feet will require you to use a 3/8 NPT street elbow to make gas connection.
9 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater Pressure T esting Heater Gas Connections: 1. Make sure that the heater supply piping sys - tem is connected and has been leak tested as described above. 2. Make sure control knob of heater is in OFF position.
10 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater C. Use only your hand to push in or turn the gas control knob. Never use tools. It knob will not push in or turn by hand, don’t try to repair it; call a qualied service technician or gas supplier .
11 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater TO TURN OFF GAS T O APPLIANCE SHUTTING OFF HEA TER: 1. T urn control knob clockwise to the OFF posi - tion. 2. T urn off all electrical power to the appliance if servicing is to be preformed.
12 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater 8. When the pilot is lit, turn control know coun - terclockwise to heating level. The main burner should light. 9. T o select the desired heat level, turn the temperature setting knob counterclockwise to between 1 & 5.
13 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater Figure 24b CLEANING AND MAINTENANCE W ARNING: T urn off heater and let cool before servicing. CAUTION: Y ou must keep control areas, burner and circulation air passageways of heater clean.
14 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater TROUBLESHOOTING NOTE: All troubleshooting items are listed in order of operation and likely occurrence. W ARNING: Only a qualied service person should service and repair heater .
15 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater TROUBLESHOOTING W ARNING: If you smell gas: • Shut off gas supply • Do not try to light any appli.
16 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater SPECIFICA TIONS IR10 LP IR20LPT IR30LPT BTU (Available) 10,000 20,000 30,000 T ype of Gas LP-Gas Only LP-Ga.
17 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater.
18 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater.
19 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater.
20 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater.
21 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater.
22 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater REPLACEMENT P ARTS Note: use only original replacement parts. This will protect you warranty coverage for parts replaced under warranty . P ARTS UNDER W ARRANTY Contact authorized dealer from whom you purchased this product.
23 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater NOTES.
24 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater W ARRANTY INFORMA TION Keep this warranty Model ______________________ Serial No. ___________________ Date Purchased _______________ Always specify model and serial numbers when communication with the factory .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Enerco MHBF6LP è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Enerco MHBF6LP - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Enerco MHBF6LP imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Enerco MHBF6LP ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Enerco MHBF6LP, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Enerco MHBF6LP.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Enerco MHBF6LP. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Enerco MHBF6LP insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.