Manuale d’uso / di manutenzione del prodotto GWT-35-2 del fabbricante Empire Products
Vai alla pagina of 20
12425-7-0406 Page 1 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL GRA VITY VENTED SINGLE W ALL FURNACE MODEL GWT -25-2(SG, RB) GWT -35-2(SG, RB) EFFECTIVE DA TE APRIL 2006 W ARNING: If the information in this manual is not followed exactly , a fire or explosion may result causing pr operty damage, personal injury or loss of life.
Page 2 12425-7-0406 T ABLE OF CONTENTS SECTION P AGE Important Safety Information ................................................................................................. 3 Safety Information for Users of LP Gas ..............................
12425-7-0406 Page 3 • DO NOT put anything around the furnace that will obstruct the flow of combustion and ventilation air . • DO keep the appliance area clear and free fr om combustible material, gasoline and other flammable vapors and liquids.
Page 4 12425-7-0406 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor .
12425-7-0406 Page 5 Model GWT -25 GWT -35 Input BTU/HR (KW/H) 25,000 (7.3) 35,000 (10.3) Height 66 1/8" (1679mm) 66 1/8" (1679mm) W idth 16" (406mm) 16" (406mm) Depth 6" (152m.
Page 6 12425-7-0406 Note: No vent equipment supplied with furnace. 4" Oval (all parts purchase locally) 1. T ype B-1 oval pipe 2. Single story type B-1 gas vents require a baseplate and one pair of ceiling plate spacers.
12425-7-0406 Page 7 Check all local codes for requirements, especially for the size and type of gas supply line required. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe T ubing, T ype L (feet) Inside Diameter Outside Diameter Nat. L.P . Nat.
Page 8 12425-7-0406 1. In selecting a location for installation, it is necessary to provide adequate accessibility clearances for servicing and proper installation. 2. Clearances to combustible surfaces are 4" (102mm) from sides, 12" (305mm) to top, 1 1/2" (38mm) from floor .
12425-7-0406 Page 9 62 1/4” (1581 mm) 14 ½” (368 mm) Figure 2 66 1/8” (1679mm) W ALL OPENING Figure 3 FINISHING INSTRUCTIONS Plastering (Figure 4) In new construction use only plain (not perforated) gypsum lath around furnace and vent pipe so that plaster "Keys" will not project into wall space.
Page 10 12425-7-0406 Figure 6 IMPOR T ANT — A void securing too tightly and disturbing the inner casing. Do not try to force furnace into a wall opening which is smaller than specified dimension. OUTER CASING (Figure 6) 1. Align 1 3/4" slot on casing bracket with bottom screw hole on inner casing.
12425-7-0406 Page 1 1 THERMOST A T LOCA TION (SG MODELS) CAUTION — Do not run wire behind flanges of Header Plate or in any location where it might be damaged. Millivolt wall thermostats are specially designed for use on self- generating systems. They should never be used on line or low voltage A.
Page 12 12425-7-0406 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
12425-7-0406 Page 13 VENT SAFETY SHUT OFF SYSTEM This appliance must be properly connected to a venting system. This appliance is equipped with a vent safety shutoff system.
Page 14 12425-7-0406 GENERAL All furnaces have been fire-tested to check for proper operation. This includes main burner flame, pilot flame, and gas control operation. If the furnace fails to function on initial installation, it is advisable to re-check the following: 1.
12425-7-0406 Page 15 USE ONL Y MANUF ACTURER'S REPLACEMENT P ARTS. USE OF ANY OTHER P ARTS COULD CAUSE INJUR Y OR DEA TH. A TTENTION: When ordering parts, it is very important that part number and description of part coincide. Index Part No. Number Description Index Part No.
Page 16 12425-7-0406 P AR TS VIEW 8 27 9 12 11 14 13 10 15 16 20 18 19 21 26 17 22 24 25 7 3 1 2 5 4 6 23.
12425-7-0406 Page 17 Index Part No. Number Description 1 GW -130 Remote Bulb Control Kit 2 R-1224 Remote Bulb Control 3 R-2499 W ire Assembly 4 R-1162 Control Knob 5 R-1720 Plastic Clip (3 Required) 6 R-1223 Instructions 7 R-1578 No. 6-32 x 1/4" (6mm) Screw (2 Required) Caution: Remote bulb wire routing is important.
Page 18 12425-7-0406 Installing Blower Using Three-Pr ong Plug 1. Install furnace according to Installation Instructions and Owner's Manual. 2. Refer to Drawing for measurements to locate (2) mounting holes on wall surface above furnace. On Solid W all 3.
12425-7-0406 Page 19 Fan Control The automatic fan control is located on the bottom of the blower assembly . The fan control is a nonadjustable, automatic type. The fan control will require between 3 and 7 minutes of main burner operation before the fan control "closes" and activates the blower .
Page 20 12425-7-0406 SER VICE NOTES Empire Comfort Systems, Inc. Nine Eighteen Freeburg A ve. Belleville, Illinois 62220-2623 PH: 1-618-233-7420 PH: 1-800-851-3153 F AX: 1-618-233-7097 F AX: 1-800-443-8648 E-MAIL: info@empirecomfort.com WEB SITE: www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Empire Products GWT-35-2 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Empire Products GWT-35-2 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Empire Products GWT-35-2 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Empire Products GWT-35-2 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Empire Products GWT-35-2, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Empire Products GWT-35-2.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Empire Products GWT-35-2. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Empire Products GWT-35-2 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.