12429-10-0408 Page 3 Introduction Al w ay s c o ns u lt y o ur lo c al Bu i ld in g D e pa r tm en t r e ga r di n g regulations, codes or ordinances which apply to the installation of a vented wall furnace. Instructions to Installer 1. Installer must leave instruction manual with owner after installation.
12429-10-0408 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical stench put into the gas. Y ou must find out if you can smell the odorant in pr opane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor .
12429-10-0408 Page 5 V entilation and Combustion Air W all furnaces shall be installed in a location in which the facilities for ventilation permit satisfactory combustion of gas and proper venting under normal conditions.
12429-10-0408 Page 6 Figure 2 Figure 3 Figur e 3A VENT CENTER TO COMBUSTIBLES MINIMUM CLEARANCE 9/16” (40mm) 4”(102mm) OVAL TYPE “B” CONNECTION 7/1/2” (191mm) MINIMUM CLEARANCE TOP T O COMBU.
12429-10-0408 Page 7 Locating Furnace On W all The furnace is to be located on a wall. The furnace is 16 inches (406mm) in width and normal 16 inches (406mm) on center studs will not allow the furnace to be recessed into the wall unless a stud is repositioned.
12429-10-0408 Page 8 Figure 6 Electrode and pilot must be kept clean. Clean through pilot access hole with a small brush (toothbrush) and water . Proper Main Burner Flame The correct flame will be a short blue inner flame with a much larger light blue outer flame.
12429-10-0408 Page 9 V ent Safety Shutoff System This appliance must be properly connected to a venting system. This appliance is equipped with a vent safety shutoff system.
12429-10-0408 Page 10 FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition devi ce which automatically lights the pilot.
12429-10-0408 Page 1 1 CALL SER VICEMAN SER VICE AND MAINTENANCE SUGGESTIONS GENERAL: All furnaces have been fire-tested to check for proper operation. This includes, main burner flame, pilot flame, fan operation, fan control, limit control and automatic valve operation.
12429-10-0408 Page 12 If the pilot does not light, or the pilot flame current is not at least 1.0 uA and steady , the module will not energize the second main valve and the main burner will not light. Safety Lockout S8600H provides 100 percent shutoff, or safety lockout.
12429-10-0408 Page 13 Important 1. The following service procedures are provided as a general guide. 2. Meter readings between gas control and ignition module must be taken within the trial for ignition period. Once the ignition module locks out, the system must be reset by setting the thermostat down for at least one minute before continuing.
12429-10-0408 Page 14 S8600H TROUBLESHOOTING GUIDE.
Gr een LED Status Codes Green LED Flash Code (X + Y) a Indicates Next System Action Recommended Service Action OFF No “Call for Heat” Not applicable None Flash Fast Startup-Flame sense calibration Not applicable None Heart Beat Normal operation Not applicable None 3 Recycle - Flame failed during run Initiate new trial for ignition.
12429-10-0408 Page 16 PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. 1 WF A-115 Baseplate Gasket 2 1 1763 Outer Casing T op 3 632024 Motor Mo.
12429-10-0408 Page 17 Empire Comfort Systems, Inc. Nine Eighteen Freeburg A ve. Belleville, Illinois 62222-0529 P AR TS VIEW.
12429-10-0408 Page 18 Model No. F A W -55 may be vented as shown. The vent cap must be at least 12 feet (3.7m) above the floor . Clearance to combustible construction is held by the fixed spacers at 1 inch (25mm) with B-1 vent pipe. Installation must conform to local codes.
12429-10-0408 Page 19 SER VICE NOTES.
12429-10-0408 Page 20 EMPIRE EMPIRE Comfo r t Systems Empire Comfort Systems Inc. 918 Freeburg A ve. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Empire Products FAW-55IP è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Empire Products FAW-55IP - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Empire Products FAW-55IP imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Empire Products FAW-55IP ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Empire Products FAW-55IP, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Empire Products FAW-55IP.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Empire Products FAW-55IP. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Empire Products FAW-55IP insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.