Page 1 INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL UNVENTED ROOM HEA TER MODELS SR-6-3 SR-10-3 SR-18-3 SR-30-3 SR-30 SHOWN This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not pr ohibited by local codes.
16942-5-0907 Page 2 Important Safety Information ............................................................................... 3 Safety Information for Users of LP Gas ............................................................... 4 Introduction ..
16942-5-0907 Page 3 • An unvented room heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom. • An unvented room heater having an input rating of more than 10,00 0 Btu pe r ho ur sh all no t be ins talle d in a be dro om or bathr oom.
16942-5-0907 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor .
16942-5-0907 Page 5 Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty card supplied with unvented room heater . 3. Installer should show owner how to start and operate unvented room heater .
16942-5-0907 Page 6 W ater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour . Unvented room heaters must be used as supplemental heat (a room) rather than a primary heat source (an entire house).
16942-5-0907 Page 7 The gas line can be routed either through the floor or wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing.
16942-5-0907 Page 8 Figure 3 (SR-6) When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches 152mm). Do not install in alcove or closet. Rear wall 0 (0mm) inches.
16942-5-0907 Page 9 Figure 5 (SR-10) CEILING WINDOW SILL OR SHELF 24” MIN (610mm) 14” MIN (356mm) 12” MAX (305mm) 0” (0mm) CLEARANCE TO REAR W ALL SIDE VIEW 2” MIN (51mm) FLOOR Figure 6 (SR-.
16942-5-0907 Page 10 When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 8 inches (203mm). Right side 8 inches (203mm). Do not install in alcove or closet. Rear wall 0 inches (0mm).
16942-5-0907 Page 1 1 On Solid W all 1. After locating mounting holes, attach (4) #10 x 1" (25mm) screws provided into the wall. Do not completely tighten screwheads to the wall, leave a 1/8" (3mm) gap between screwheads and wall. 2. Mount heater onto the (4) screwheads and complete tightening screwheads into the wall.
16942-5-0907 Page 12 1. Align clearance holes on floor stand with screw holes on bottom of heater , as shown in Figure 14. 2. Attach floor stand to heater with (4) screws provided with floor stand. 3. Connect the gas line. *Floor stand can not be used in a bathroom or bedroom installation.
16942-5-0907 Page 13 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
16942-5-0907 Page 14 SR-6 Main Burner Flame (Figur e 15) The main burner flame will have a red-orange glow over the sur- face of the ceramic plaque. The red-orange glow on the surface of the ceramic plaque will have a pattern in the shape of a number 1.
16942-5-0907 Page 15 The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip.
16942-5-0907 Page 16 1. Spark electrode does not produce spark. a. Spark electrode broken - replace. b. Ignitor wire may not be attached to spark electrode - attach. c. Ignitor wire damaged - replace. d. Piezo ignitor defective - replace. 2. Spark electrode produces spark but pilot does not light.
16942-5-0907 Page 17 USE ONL Y MANUF ACTURER'S REPLACEMENT P AR TS. USE OF ANY OTHER P AR TS COULD CAUSE INJUR Y OR DEA TH. Parts can be ordered only through your service person or dealer . For best results, the service person or dealer should order parts through the distributor .
16942-5-0907 Page 18 USE ONL Y MANUF ACTURER’S REPLACEMENT P AR TS. USE OF ANY OTHER P AR TS COULD CAUSE INJUR Y OR DEA TH. SR-18 INDEX NUMBER P ART NUMBER DESCRIPTION 1 13346 CASING SIDE ASSEMBL Y .
16942-5-0907 Page 19 SR-6 P AR TS VIEW.
16942-5-0907 Page 20 SR-10 P AR TS VIEW.
16942-5-0907 Page 21 SR-18 P AR TS VIEW.
16942-5-0907 Page 22 SR-30 P AR TS VIEW.
16942-5-0907 Page 23 INST ALLING OPTIONAL BLOWER SRB-18 OR SRB-30 If heater is installed onto the wall, in order to install the optional blower, the heater must be removed from the wall. If heater is installed on op - tional floor stand there is adequate access area available to install the optional blower .
16942-5-0907 Page 24 Wiring The appliance, when installed , must be electr ically grounde d in accordance with local codes or , in the absence of local codes, with the National Electri - cal Code, ANSI/NFP A 70, if an external electrical source is utilized.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Empire Comfort Systems SR-30 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Empire Comfort Systems SR-30 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Empire Comfort Systems SR-30 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Empire Comfort Systems SR-30 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Empire Comfort Systems SR-30, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Empire Comfort Systems SR-30.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Empire Comfort Systems SR-30. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Empire Comfort Systems SR-30 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.