Manuale d’uso / di manutenzione del prodotto HD7005 del fabbricante Emerson
Vai alla pagina of 16
Pa rt No . SP6470 Printed in Canada CAUTION: Read all instructions carefully before installation. Save this Owner ’ s Manual for future reference. Moist AIR ™ HD7002 & HD7005 Evaporative Console Humidifier Owner ’ s Manual EMERSON ® Model Nos.
Safety Signal Words DANGER: means if the saf ety information is not f ollowed, someone will be seriously injured or killed. W ARNING: means if the safety inf ormation is not f ollowed, someone could be serious- ly injured or killed. CAUTION: means if the saf ety information is not f ollowed, someone may be seriously injured or killed.
3 Description HD7002 & HD7005 Gallon Output / 24 hrs 7 Litre Output / 24 hrs. 26.5 Capacity of Bottle 2.5 Gallons Capacity of Bottle 9.4 Litres * Sq. Ft. Cov erage 1500 F an Speeds 3 Number of Filters 2 Fill Light Y es A uto Humidistat Y es A uto Shut Off Y es Controls Rotar y CUL Listed Y es V olts 120 A.
4 Humidifier Operations Y our new Emerson humidifier is designed to satisfy home humidity requirements through the principle of ev aporation of w ater into the air . After water is added to the bottle and positioned in the humidifier , the filters begin to soak up the water and become totally saturated in appro ximately 30 min- utes.
W ARNING : For your own safety , do not use humidifier if any parts are damaged or missing. 1. Place humidifier on a flat le vel surf ace in area of house where most humidity is needed, or an area which would lik ely result in moist air being circulated throughout the house, such as near a cold air return.
To fill this humidifier , close the control cov er and remov e the bottle cov er . T o remov e the w ater bottle , lift the bottle straight up and out of the cabinet. The water bottle is designed with an “E-Z- Fill Side-Cap”. Remove the “E-Z-Fill Side- Cap” on the side of the water bottle b y twist- ing counterclockwise .
Operating Humidifier Controls The operating controls of y our Emerson ev aporativ e humidifier are located on the top right of the humidifier . The controls are f ound under the smoked co ver Lift the control cov er by placing y our finger in the round cutout and lifting.
8 Operating T ips for Best Performance 1. Position the humidifier at least 2 inches from any w all and aw ay from an y heat registers. 2. Do not restr ict airflow from entering or e xiting the humidifier . 3. Use liquid EP A-approved bacteriostat to retard bacteria growth that ma y cause odors and ma y be har mful to y our health.
9 Replacement and Care of Filters W ARNING: T o reduce the risk of shock or injury from moving parts, always unplug humidifier before removing or replacing any parts. CAUTION: T o help retard bacteria growth and keep maximum efficien- cy , the filters should be replaced at least once a season, or more often under hard water conditions.
3. a. Remove the two filters and dispose of properly . b. Clean internal par ts of the humidifier per the “Cleaning Y our Humidifier” section of your o wner’ s manual. c. Install new filters inside the cabinet with the glue beads on the filter f ac- ing the center of the cabinet.
W ARNING: T o reduce the risk of injury , fire or damage to humidifier , use only cleaners specifically rec- ommended for humidifiers. Never use flammable, combustible or poi- sonous materials to clean your humidifier . T o reduce the risk of scalds and damage to humidifier , never put hot water in humidifier .
Bi-Weekly Maintenance Removing Scale 1. Pour one 8 ounce cup of undiluted white vinegar into the cabinet. Let solu- tion sta y in for 20 min utes. 2. Clean all inter ior surfaces with a soft brush. Dampen a soft cloth with undi- luted white vinegar and wipe out the cabinet to remov e scale.
13 T roubleshooting PROBABLE CAUSE • Speed control in off position. • Selected humidity lev el is obtained. • No power . • Float is not free. • This is nor mal. • Air is entering water bottle. • Dir ty filters. • Bottle cap plunger missing post in bottom of cabinet.
14 Repair Parts P ARTS LIST FOR EMERSON HUMIDIFIER MODEL NO. HD7002 1 & HD7005 0.
15 Repair Parts FOR P AR TS: If in the USA call 1-800-654-3545 If in Canada call 1-866-258-7847 For more information about Emerson Moist AIR ™ humidifiers visit our website at www .
9999 Highway 48 Markham, Ontario Canada L3P 3J3 Pa rt .N o. SP6470 F or m. No . SP6470 Printed in Canada 06/02 FOR TECHNICAL HELP , CALL (800) 654-3545 FROM USA OR (888) 744-4687 FR OM CANAD A (Please hav e complete model number) TM © 2002 Emerson Electric Co.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Emerson HD7005 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Emerson HD7005 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Emerson HD7005 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Emerson HD7005 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Emerson HD7005, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Emerson HD7005.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Emerson HD7005. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Emerson HD7005 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.