READ AND SA VE THESE INSTRUCTIONS Part No. F40BP73500000 Form No. BP7350 U.L. Model No.: CF3200 Net Weight: 26.0 Lbs. Model Numbers B A T ON R OUGE ™ Ceiling F an Owner's Manual CF3200AWL00 Sum.
2 WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference 2.
3 This Manual Is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan One stepladder One wire stripper One Phillips head screwdriver Four 15-watt (max.) candelabra base bulbs MA TERIALS Wiring outlet box and box connectors must be of type required by the local code.
1. Place the flange assembly onto the bottom of the blade assembly. Place the flange medallion assembly into the four holes of the blade assembly. 2. Secure the flange assembly and flange medallion to the blade assembly using the four #10-32 x 10mm pan head screws.
7. Remove the wire connector from the white wire of the switch housing plate. Retain for the next step. 8. Connect the white wire from the switch housing plate to the white wire of the switch housing, using the wire connector previously removed (Figure 3).
6 YELLOW FAN WIRE ONE-PIN CONNECTOR LIGHT KIT ASSEMBL Y WHITE LIGHT KIT ASSEMBL Y WIRE WHITE FAN WIRE YELLOW LIGHT KIT ASSEMBL Y WIRE Figure 8 15-WA TT CANDELABRA BASE LIGHT BULB (4) LIGHT KIT ASSEMBL Y SOCKET (4) Figure 9 15. Securely connect the white fan one-pin connector wire to the white one-pin connector wire from the light kit assembly.
7 DOWNROD HAIRPIN CLIP CLEVIS PIN SETSCREW CLEVIS PIN MOTOR COUPLING DOWNROD HAIRPIN CLIP MOTOR COUPLING Figure 12 It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
8 28. The blue, black, white, and yellow leads exiting the downrod are 80-inches long. Before installing the fan, measure up approximately 6 to 9-inches above the ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.
9 Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.
1-1/4" THREADED STUD (2) CEILING COVER KNURLED KNOB (2) LOCKWASHER (2) 1-1/4" THREADED STUDS (2) HANGER BRACKET OUTLET BOX RECEIVER CEILING COVER Figure 25 WHITE SUPPL Y WIRE BLACK FAN WIRE .
The SW116 wall control transmits the command signals via radio waves to the SW105 receiver installed in the ceiling fan ceiling cover. The SW105 receiver is required for the SW116 wall control to function. Power for the SW116 wall control comes from the 12V battery, located in the wall control.
Operating Y our Ceiling F an IMPORT ANT Fan installation must be completed, including the installation of the fan blades, before testing of the remote control. NOTE: The downlight button will not work unless an Emerson light kit is added to the ceiling fan.
13 T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. WARNING: Make sure main power is turned off. 2. Loose power line connections to the fan.
14 3 10 11 2 1 9 6 31 32 18 10 11 9 5 9 4 8 7 8 33 34 17 19 20 22 23 28 13 14 15 16 BLADE 10-32 x 10mm PAN HEAD SCREW (4 Per Blade) FLANGE ASSEMBL Y FLANGE MEDALLION 26 24 21 12 25 27 29 30 H I H I M E D M E D L O W L O W F A N O F F R E V R E V L I G H T 34 R epair Par ts U.
15 R epair Par ts Listing Key Model No. N o. Description CF3200AWL00 CF3200DBZ00 * Hanger Pack, Consisting of: 761655-69 761655-68 1 Hanger Bracket — — 2 Hanger Ball — — 3 Downrod - 12” — — * Parts Bag Containing: 763463-1 763463 4 Pin, Clevis (1) — — 5 Clip, Hairpin (1) — — 6 Wire Connector, 12 Ga.
Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Printed in China 11/07 Form No. BP7350 Part No. F40BP73500000 U.L. Model No.: CF3200 LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson Electric Co.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Emerson CF3200AWL00 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Emerson CF3200AWL00 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Emerson CF3200AWL00 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Emerson CF3200AWL00 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Emerson CF3200AWL00, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Emerson CF3200AWL00.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Emerson CF3200AWL00. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Emerson CF3200AWL00 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.