Cello Digital Servo Drive Cable Kits Main Feedback: CBL-DFDBK (general purpose) CBL-DFDBK-5 Encoder: CBL-MTRENC2 (for SAR, SA,SB,SC) CBL-MTRENC2-5 Encoder: CBL-MTRENC4 (for SE) CBL-MTRENC4-5 Aux. Feedback: CBL-CELAUX -5 CBL-CELAUX-5 General I/O: CBL-CELIO1 -5 (J1) CBL-CELIO1-5 General I/O: CBL-CELIO2 -5 (J2) CBL-CELIO2-5 Aux.
Important Notice This guide is delivered subject to the following conditions and restrictions: This guide contains proprietary informatio n belonging to Elmo Motion Control Ltd. Such information is supplied solely for the purpose of assisting users of Elmo’s Cello servo drives in assembling the required cables for their drive.
Contents 1. Introduct ion ................................................................................................................ ............. 1 1.1 Cello Connectors ...........................................................................
1. Introduction This document provides the wiring details fo r the cables used to connect Cello digital servo drives with the end-user application. The servo drive-side pinouts are provided in Chapter 3 of the drive’s installation guide. The cables come in two lengths: 2 meters (6 ½ feet) and 5 meters (16 ½ feet).
Type Function Port Connector Location 8-pin RJ-45 CANopen CAN 8-pin RJ-45 CANopen CAN 15-pin D-Sub (high-density) Feedback B Feedback B 8-pin RJ-45 RS-232 RS-232 Table 1-3: The Cello’s Communications and Feedback B Connectors 1.2 Cable Cross-Reference Cable Application Cable Part.
2. Cable Kits Several Cable Kits can be purchased from Elmo. Each contain a set of 8 cables. The -5 suffix on the kits and on the cables (CBL-DFDBK-5 fo r example) indicate that the cables are 5m long. Cables and kits without that suffix are 2m long (except for CBL-RJ45CAN2 which is 20cm long).
3. Main Feedback Cables The main feedback cables are made of 24-AWG sh ielded cable. There are 3 types of feedback cables, all use a 15-pin D-sub plug which connects to the FEEDBACK A port on the Cello. • The General-Purpose Main Feedback Cable (CBL-DFDBK) is open on the motor side so that it can be connected to customer-specific connectors.
3.2 Encoder Cable (CBL-MTRENC2 -5 for SAR, SA, SB, SC) D-Type Pin No. Color Socket Pin No. Signal Pair Description 1 10 Green Yellow 11 9 HC HB pair Hall sensor C input Hall sensor B input 2 Pink 7 HA.
3.3 Encoder Cable (CBL-MTRENC4 -5 for SE) D-Type Pin No. Color Socket Pin No. Signal Description 1 Green P HC Hall sensor C input 10 Yellow M HB pair Hall sensor B input 2 Pink K HA Hall sensor A inpu.
4. Auxiliary Feedback Cable (CBL-CELAUX -5) The auxiliary feedback cable is a 24-AWG shielded cable. It is connected using an 15-pin Hi-density D-sub plug which connects to the Cello’s FEEDBACK B port.
5. General I/O J1 (CBL-CELIO1 -5 ) The digital input cable is a 24-AWG shielded cable. It is connected using an 15-pin Hi- Density D-sub socket. Pin Color Signal Pair Function Pin Position 1 Orange IN.
6. General I/O J2 (CBL-CELIO2 -5 ) The digital output cable is a 26-AWG shielded cable. It is connected using a 15-pin Hi- Density D-sub plug. Pin Color Signal Pair Function Pin Position 1 Orange IN5 .
7. Auxiliary Power Cable (CBL-CEL24 -5 ) The auxiliary power cable is a 24-AWG shie lded cable terminated by pins on the SimplIQ side. The pins are screwed into the 2-pole Pheonix Terminal Block provided with the Cello.
8.2 Motor Power Cable (CBL-MTRPWR1CEL -5 ) CBL-MTRPWR1CEL -5 is a 24-AWG shielded cable in which each wire, on the SimplIQ drive side, is connected to a pin terminal and the wires on the motor side are connected to a 4-pole socket. This cable is designed for connecting a Cello to a Metronix APM-SAR, SA, SB or SC motor.
9. Communication Cables The communication cables use 26-AWG twisted pair shielded cable. They are connected using an 8-pin RJ-45 plug. Elmo drives can communicate using the following options: RS-232, full duplex CANopen 9.1 RS-232 Option (CBL-RJ452321 -5 ) RJ45 Pin No.
9.2 CAN Option (CBL-RJ45CAN1 -5 ) RJ45 Pin No. Color D-type Female Pin No. Signal Description 1 Green 7 CAN-H CAN_H bus line 2 Yellow 2 CAN_L CAN_L bus line 3 White 3 CAN_GND CAN ground 4 — — — .
9.3 CAN Option (CBL-RJ45CAN2) Cable CBL-RJ45CAN2 is 20 cm long, it is used for “daisy-chaining” CAN nodes. On the Harmonica this cable is connected to the External Dual Can Port.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Elmo CBL-MTRENC4 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Elmo CBL-MTRENC4 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Elmo CBL-MTRENC4 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Elmo CBL-MTRENC4 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Elmo CBL-MTRENC4, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Elmo CBL-MTRENC4.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Elmo CBL-MTRENC4. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Elmo CBL-MTRENC4 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.