Manuale d’uso / di manutenzione del prodotto QB5500 del fabbricante Electrolux
Vai alla pagina of 25
Gasoline Generators Operator Manual.
2 Thank you for purchasing our generat or. We want to help you get th e best results from your new generator and to operate it safely. Th is manual contains the informat ion on how to do that; please read it carefully. This owner’s manual describes t he operation and maintenance of the Generator.
3 Table Of Contents SAFETY 2 SAFETY LABEL LOCATION 4 SAFETY INFORMATION 5 Component Identification 6 CONTROLS 7 Engine Switch 7 Recoil Starter 7 Fuel Valve 7 Choke Rod 8 Circuit Breaker 8 Ground Termi.
4 SAFETY LABEL LOCATION These labels warn you of potential hazards that c an cause serious injury. Read them carefully. If a label comes off or becomes har d to read, contact your generat or dealer for a replacement.
5 WARNING! Do not connect to a building’s el ectrical system unless a transfer switch has been installed by a qualified electrician. Using a generator or an electrical appliance in wet conditions such as rain or snow or near a pool or sprinkler system , or when your hands ar e wet, could result in electrocution.
6 • Do not smoke or allow flames or sparks wher e the generator is refuel ed or where gasoline is stored. • Refuel in a well-ventila ted area with the engine stopped. Fuel vapors are extremely flammable and may ignite a fter the engine has started.
7 CONTROLS Engine Switch To start and stop the engine. Switch position: OFF: To Stop the engine. Key can be r e m o v e d / i n s e r t e d . ON: To run the engine after starting. START: To start the engine by turning t h e s t a r t e r m o t o r . Return the key to the ON posi tion once the en gine has started.
8 Choke Rod The choke is used to pr ov ide an enriched fuel mixture when cold star ting. The choke can be opened by moving the choke rod to the right and closed by moving the choke rod to the left .
9 battery must be connected to the generator DC terminals with the proper polarity (battery positive to generator red terminal and battery negativ e to the generator black terminal.
10 exceed that of the gener ator, Never exceed the maximum power rating of the generat or. Power levels between rated and maximum may be used for no more than 5 minutes.
11 Disconnecting the battery cables: 1. Stop the engine. 2. Disconnect the negative (-) battery cable from the generator negative (-) terminal. 3. Disconnect the other end of t he negative (-) battery cabl e from the battery negative (-) terminal. 4. Disconnect the positive (+) battery cabl e from the generator positive (+) terminal.
12 Fuel Recommendation 1. Check the fuel level gauge. 2. Refill the tank if the fuel level is low. Do not fill above the shoulder of the fuel strainer. WARNING Gasoline is extremely flammable and is exp losive under certain condi tions. Refuel in a well-ventilated area with the engine stopped.
13 Gasoline containing more than 10% ethanol by volume may caus e starting and/or performance problems. Gasoline containing ethanol ma y be marketed under the name Gasohol. Methanol (methyl or wood alcohol) Gasoline containing methanol must c ontain co solvents and corrosion inhibitors to protect the fuel system.
14 STOPPING In an emergency: 1. To stop the engine in an emergency, turn the engine switch to the OFF position. In normal use: 1. Turn the AC circuit br eaker to the OFF position. 2. Disconnect all electrical loads from panel receptacles. Disconnect DC battery charging cables.
15 Maintenance Schedule Notes 1) Service more frequently when used in dusty areas. 2) These items should be serviced by an aut horized generator dealer, unless owner has proper tools and is mechanically proficient. 3) For professional commercial use, log hours of operation to determine proper maintenance intervals.
16 Please dispose of used motor oil in a manner that is compatible with the environment. We suggest you take it in a sealed container to your local service st ation or recycling center for disposal. Do not throw it in the trash or pour it on the ground.
17 Fuel Sediment Cup Cleaning The sediment cup prevents dirt or water, which may be in the fuel t ank, from entering the carburetor. If the engine has not been run for a long time, the sediment cup should be cleaned. 1 . Turn the fuel valve to the OFF posi tion.
18 NOTICE The spark plug must be securely tightened. An improperly tightened spark plug can become very hot and could damage the engine. Never use spark plugs which have an improper heat range. Use only the recommended spark plugs or equivalent. TRANSPORTATI ON/STORAGE When transporting the generator, turn the engine swit ch and the fuel valve OFF.
19 Gasoline is extremely flammable and is explosi ve under certain conditions Perform this task in a w e l l v e n t i l a t e d area wi th the engine stoppe d . Do not smoke or allow flam e s o r s p a r k s i n t h e a r e a during this procedure. 1.
20 TROUBLE SHOOTING TYPICAL WIRING DIAGRAM.
21 SPECIFICATIONS Generator Model QB1300 QB2800 QB3300 QB5500E QB7700E Frequency(Hz) 60Hz 60Hz 60Hz 60Hz 60Hz Rated AC voltage (volts) 120 120 120 120/240 120/240 AC Circuit breaker 10A(1pc) 22A (1pc).
22 TYPICAL WATTAGES Appliances Surge Wattage (Startup) Running Wattage Automatic Washer 2300 1150 Blender 900 300 Ceiling Fan 1200 800 Clock Radio 100 100 Clothes Dryer (Gas) 1200 700 Coffee pot (10 c.
23 Electronics Surge Wattage (Startup) Running Wattage CD player 100 100 Color Television 300 300 Desktop Computer 600 to 800 600 to 800 DVD player 100 100 Fax 600 to 800 600 to 800 Laptop Computer 20.
24 Power Equipment Surge Wattage (Startup) Running Wattage Air Compressor (1 HP) 4500 1600 Air Compressor (1/2 HP) 1600 975 Battery Charger: 100 Amp with 300 Amp Boost 2400/7800 2400/7800 Battery Char.
25 Limited Warranty Queen Bee Power™ Generators are warranted by Jae Enterprises, Inc. to the original retail con sumer against defects in material and workmanship for a period of one (1) year from the date of retail purchase and is not transferable.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Electrolux QB5500 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Electrolux QB5500 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Electrolux QB5500 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Electrolux QB5500 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Electrolux QB5500, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Electrolux QB5500.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Electrolux QB5500. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Electrolux QB5500 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.