Manuale d’uso / di manutenzione del prodotto WP-1000 T1E del fabbricante Echo
Vai alla pagina of 32
X750012624 03/13 W ater Pump Operator's Manual MODEL WP-1000 WP-1000 T1E W ARNING U sers of this equip men t risk inj ur y to themselv es and o thers if the unit is used im- pr operly a nd/or saf ety pr ecau tions a re no t follo wed. ECH O pr ovides a n operat or ’ s man ual.
2 CopyRight© 2013 By Echo, Incorporated All Rights Reserved. T able of C onTenTs Introduction ................................................................ 2 - The Operator's Manual ....................................... 2 Safety ...........
W a ter P umP O Pera tOr ' s m anual 3 s afeTy m anual s afeTy s ymbols and I mporT anT I nforma TIon W ARNING The safety alert symbol accompanied by the word “W ARNING” calls attention to an act or condi- tion which CAN lead to serious personal injury or death if not avoided.
4 Symbol description/application Symbol form/shape Symbol description/application Symbol form/shape Hot Surface Carburetor adjustment - Idle speed Carburetor adjustment - High speed mixture Symbol des.
W a ter P umP O Pera tOr ' s m anual 5 W ARNING W ater can be a conductor of electric current when exposed to live electrical wiring. Electrocution will result. • Do not operate pump in ooded basements without rst shutting off electricity from outside the house.
6 equIpmenT Before operation a complete check of the unit must be performed; • Check unit for loose/missing nuts, bolts and screws. T ighten and/or replace as needed. • Inspect guards and shield for damage and ensure that they are securely in place.
W a ter P umP O Pera tOr ' s m anual 7 Hot Decal (near mufer) Extra parts for discharge hose d esCrIpTIon Locate the safety decal on your unit. Make sure the decal is legible and that you understand and follow the instructions on it. If a decal cannot be read, a new one can be ordered from your ECHO dealer .
8 1. SP ARK ARREST OR MUFFLER OR SP ARK ARRESTOR MUFFLER WITH CA T AL YST - The mufer or catalytic mufer controls exhaust noise and emission. The spark arrestor screen prevents hot, glowing particles of carbon from leaving the mufer . Keep exhaust area clear of ammable debris.
W a ter P umP O Pera tOr ' s m anual 9 ____ 1 - Pump Assembly ____ 1 - Suction Hose (#21) ____ 1 - Operator's Manual ____ 1 - Emission Control W arranty Statement ____ 1 - W arranty Registra.
10 H B D C E E dIsCharge hose Garden Hose NOTE Garden hose ranging from 13 mm (1/2 inch) to 19 mm (3/4 inch) in diameter can be used on the discharge end of this pump. 1. Remove vinyl cap from pump discharge port. 2. Attach the 25 mm to 3/4 inch adaptor (H) and washer (E) tightly onto pump discharge port.
W a ter P umP O Pera tOr ' s m anual 11 NOTICE: Use of unmixed, improperly mixed, or fuel older than 90 days, (stale fuel), may cause hard starting, poor performance, or severe engine damage and void the product warranty . Read and follow instructions in the Storage section of this manual.
12 Mixing Instructions 1. Fill an approved fuel container with half of the required amount of gasoline. 2. Add the proper amount of 2-stroke oil to gasoline. 3. Close container and shake to mix oil with gasoline. 4. Add remaining gasoline, close fuel container , and remix.
W a ter P umP O Pera tOr ' s m anual 13 1. Select a rm, level site as near the water source as possible. Never exceed a suction lift (A) of 7.5 m (24 feet) or water will not ow . Make sure pump will not move due to vibration and/or the pull from the weight of suction hose when full of water .
14 A B C D E W ARNING W ater can be conductor of electric current when exposed to live electrical wiring. Electrocution will result. • Do not operate pump in ooded basements without rst shutting off electricity from outside the house. Pump should be located outside in a vented area.
W a ter P umP O Pera tOr ' s m anual 15 sT arTIng w arm engIne The starting procedure is the same as Cold Start except DO NOT close the choke. 1. Move ignition switch (A) to start, move throttle lever (D) towards engine to idle position. Pull starter handle (E) and engine should start.
16 Y our ECHO water pump is designed to provide many hours of trouble free service. Regular scheduled maintenance will help your water pump achieve that goal. If you are unsure or are not equipped with the necessary tools, you may want to take your unit to an ECHO Service Dealer for maintenance.
W a ter P umP O Pera tOr ' s m anual 17 aIr fIl Ter Level 1. Parts r equir ed: REPOWER AIR & FUEL FIL TER KIT . 1. Close choke (Cold Start Position [ ]). This prevents dirt from entering the carburetor throat when the air lter is removed. Brush accumulated dirt from air cleaner area.
18 CoolIng sysTem Level 2. Parts Requir ed: None. IMPOR T ANT T o maintain proper engine operating temperatures, cooling air must pass freely through the cylinder n area.
W a ter P umP O Pera tOr ' s m anual 19 NOTE The throttle cable remains assembled to the engine cover and the spark plug lead and grommet remain installed. IMPOR T ANT DO NOT use a metal scraper to remove dirt from the cylinder ns. 3. Use the brush to remove dirt from the cylinder ns.
20 Exhaust Port Cleaning Level2. Parts Requir ed: As needed: Heat Shield 1. Remove engine cover . See “Cleaning Cooling System” for step by step instructions.. 2. Place piston at top dead center . Remove mufer (A) and heat shield (B). 3. Use a wood or plastic scraping tool to clean deposits from cylinder exhaust port.
W a ter P umP O Pera tOr ' s m anual 21 CarbureTor adjusTmenT Engine Break-In New engines must be operated a minimum duration of two tanks of fuel break-in before carburetor adjustments can be made. During the break- in period your engine performance will increase and exhaust emissions will stabilize.
22 (Non Emissions Models W ithout Limiter Caps) 1. Before adjusting the carburetor, clean or replace the air lter and spark arrester screen. 2. Fill pump housing with clean water . 3. Start engine and run for several minutes to reach operating tem - perature.
W a ter P umP O Pera tOr ' s m anual 23 A B C D E F G pump CasIng Should the pump become clogged with debris: 1. Disconnect the spark plug wire. 2. Remove the prime port plug (A) and drain plug (B) from the pump housing (C) and drain the water from the pump.
24 T roubleshooTIng DANGER Fuel vapors are extremely ammable and may cause re and/or explosion. Never test for ignition spark by ground- ing spark plug near cylinder plug hole, otherwise serious personal injury may result.
W a ter P umP O Pera tOr ' s m anual 25 No water delivered or not enough water delivered •Pump not primed •Speed too low •Suction line clogged •Suction lift too high •Air leak in suction line •Fill pump body with water. •Pump should operate at 5600-6300 rpm.
26 7. A. Allow engine to cool then r emov e the spark pl ug and pour 7 cc (1/4 oz.) o f fresh, clean, two-s troke engine oil in to the cylinder through the spark pl ug hole. B. Plug the recoil starter handle 2-3 times to distribute the oil inside the engine.
W a ter P umP O Pera tOr ' s m anual 27 s peCIfICa TIons MODEL ---------------------------------------------------- WP-1000 Length ------------------------------------------------------- 310 mm (12.2 in.) W idth -------------------------------------------------------- 226 mm (8.
28 ECHO LIMITED W ARRANTY ST A TEMENT FOR PRODUCT SOLD IN USA AND CANADA BEGINNING 01/01/2010 ECHO'S RESPONSIBILITY ECHO Incorporated’s Limited W arranty , provides to the original purchaser that this ECHO product is free from defects in material and workmanship .
W a ter P umP O Pera tOr ' s m anual 29 PURCHASED REP AIR P ARTS, SHORT BLOCKS AND ACCESSORIES .
30 noTes.
W a ter P umP O Pera tOr ' s m anual 31 noTes.
CONSUMER PRODUCT SUPPORT 1-800-673-1558 8:30 - 4:30 Mon - Fri C.S.T . ECHO, INCORPORA TED 400 Oakwood Road Lake Zurich, IL 60047-1564 www .echo-usa.com 001001/999999 501001/599999 W15103001001/W15103999999 DEALER? Call 1-800-432-ECHO 1-800-432-3246 or www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Echo WP-1000 T1E è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Echo WP-1000 T1E - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Echo WP-1000 T1E imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Echo WP-1000 T1E ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Echo WP-1000 T1E, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Echo WP-1000 T1E.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Echo WP-1000 T1E. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Echo WP-1000 T1E insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.