Publication No. MN05001001E February 2002 New Intelligent T echnologies QCPort Starter Network Adapter Product (QSNAP) Installation and User Manual.
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E February 2002 Important Notice – Please Read The product discussed in this literature is subject to terms and conditions outlined in appropriate Eaton’ s Cutler -Hammer selling policies.
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E i February 2002 T able of Contents PRODUCT OVERVIEW Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features and Benefits .
Intelligent Technologies ( IT. ) QSNAP ii Pub. No. MN05001001E February 2002 List of Figures Figure 1: QSNAP Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Figure 2: QSNAP Dimensions, mm [in] . . .
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 1 February 2002 Product Overview Description Cutler -Hammer Intelligent T echnologies ( IT . ) QSNAP (QCPort Starter Network Adapter Product) by Eaton Corporation is the result of a substantive engineering and marketing effort, involving extensive customer input.
Intelligent Technologies ( IT. ) QSNAP 2 Pub. No. MN05001001E February 2002 Features and Benefits The IT . QSNAP includes the following significant features: ● Communication to QCPort consuming a single QCPort ID ● Control of non-reversing and reversing Eaton’ s Cutler -Hammer Intelligent T echnologies ( IT .
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 3 February 2002 Safety The following safety statements relate to the installation, setup and operation of Eaton’ s Cutler -Hammer IT .
Intelligent Technologies ( IT. ) QSNAP 4 Pub. No. MN05001001E February 2002 Environmental Ratings The following environmental ratings apply to the QSNAP . T able 3: Environmental Ratings Approvals/Certifications The following approvals and certifications apply to the QSNAP .
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 5 February 2002 Physical Features Physical Description Figure 1 illustrates the front and back of the IT . QSNAP and its various features. Figure 1: QSNAP Features Dimensions Figure 2 illustrates the dimensions of the IT .
Intelligent Technologies ( IT. ) QSNAP 6 Pub. No. MN05001001E February 2002 Power Source The IT . QSNAP is designed for use with 24V DC power . The QSNAP uses power from two sources when operating properly; these sources are the QCPort subnet and the Eaton ’ s Cutler -Hammer Intelligent T echnologies ( IT .
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 7 February 2002 CAUTION Only apply 24V DC to the QSNAP . Use of any other voltage may result in personal injury , property damage and damage to the QSNAP .
Intelligent Technologies ( IT. ) QSNAP 8 Pub. No. MN05001001E February 2002 Operation This section provides details about the following features and aspects of QSNAP operation: ● “ Out of box ” .
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 9 February 2002 T ypical Application The following fi gure illustrates a typical QSNAP application, where a single QSNAP is connected to one motor controller and where the motor controllers are distributed throughout QCPort.
Intelligent Technologies ( IT. ) QSNAP 10 Pub. No. MN05001001E February 2002 Enhanced Features The QSNAP offers a variety of enhanced features, including: settable warnings, current threshold warning, underload warning and reset. T o help diagnose an application, a fault queue is provided to view the last fi ve faults.
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 11 February 2002 Input/Output Data The QSNAP offers a standard data list (shown below) for default operation. The list is con fi gurable with data contained within T able 21 in Appendix A: QSNAP Parameters , using the CH Studio application.
Intelligent Technologies ( IT. ) QSNAP 12 Pub. No. MN05001001E February 2002 T able 11: Default Input Data Output Data Use T ables 12 and 13 when setting up the QSNAP output data.
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 13 February 2002 Status LED The status LED is located on the lower right of the QSNAP as pictured in Figure 1: QSNAP Features . The LED ’ s status changes depending on the state of the QSNAP .
Intelligent Technologies ( IT. ) QSNAP 14 Pub. No. MN05001001E February 2002 Configuration The only con fi guration that is necessary for normal operation of the QSNAP is setting the Group ID and SW1 positions A and B, as described in the “ Installation ” section.
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 15 February 2002 Installation Set the Group ID The Group ID refers to the logical QCPort group to which the QSNAP belongs. For further information on the explanation of Group ID and the system con fi guration, see the IT .
Intelligent Technologies ( IT. ) QSNAP 16 Pub. No. MN05001001E February 2002 SW1 Settings SW1 is used to set the existence of the second Aux contact and the external ground fault. T able 16: SW1 Settings Mount the IT . QSNAP to the Starter The IT . QSNAP is designed to be installed in the auxiliary contact locations of the IT .
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 17 February 2002 Use the following steps and the illustration in Figure 7 to mount the QSNAP . 1. Align both the QSNAP feet with the auxiliary contact mounting slots on the starter , as illustrated in the fi gure.
Intelligent Technologies ( IT. ) QSNAP 18 Pub. No. MN05001001E February 2002 Wire the IT . QSNAP to the Starter The QSNAP is connected to the IT . starter using a factory-provided jumper with an RJ-45 plug on one end and a pigtail on the other . The pigtail is color coded to facilitate accurate connection to the overload terminal block.
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 19 February 2002 2. T o lock the starter interface to the overload, rotate the orange locking tabs until the tab is locked into the slots in the overload. Use Figure 11 for information on which way to rotate the locking tabs.
Intelligent Technologies ( IT. ) QSNAP 20 Pub. No. MN05001001E February 2002 T roubleshooting and Maintenance Renewal Parts The renewal parts for the QSNAP are shown in the following table.
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 21 February 2002 Appendix A: QSNAP Parameters Refer to the following table when con fi guring the QSNAP .
Intelligent Technologies ( IT. ) QSNAP 22 Pub. No. MN05001001E February 2002 T able 22: Data Parameters Number Parameter Units Length 11 Motor Control 1 12 Motor Control Status 1 13 Motor Control Faul.
Intelligent Technologies ( IT. ) QSNAP Pub. No. MN05001001E 23 February 2002 Intelligent T echnologies ( IT . ) Publications and Support T able 23: IT . Publications For copies of these and other publications contact the Literature Ful fi llment Center at 1-800-957-7050.
Intelligent Technologies ( IT. ) QSNAP 24 Pub. No. MN05001001E February 2002.
.
© 2002 Eaton Corporation All Rights Reserved Publication No. MN05001001E February 2002 Printed in USA Eaton Corporation Cutler -Hammer business unit 1000 Cherrington Parkway Moon T ownship, P A 15108-4312 USA tel: 1-800-525-2000 www .cutler-hammer .eaton.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Eaton Electrical QSNAP è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Eaton Electrical QSNAP - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Eaton Electrical QSNAP imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Eaton Electrical QSNAP ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Eaton Electrical QSNAP, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Eaton Electrical QSNAP.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Eaton Electrical QSNAP. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Eaton Electrical QSNAP insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.