Manuale d’uso / di manutenzione del prodotto RMC-KFA120TDLX, RMC-KFA170TDLX del fabbricante Dyna-Glo
Vai alla pagina of 12
4 2 2 1- 0 0 5 9 - 0 0 06/04 Rev. 00 EDITION 2004 PORTABLE FORCED AIR HEA TERS “USER’S MANUAL” Before the first use of this heater, please read this USER’S MANUAL very carefully.
2 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! ITEM P AGE # PRECAUTIONS - SAFETY GUIDE 1 1. INTRODUCTION 2 2. FEATURES 2 3. UNPACKING AND ASSEMBLY 4 4. KEROSENE (1-K OR NO. 1 FUEL OIL) 6 5. OVERVIEW OF HEATER DESIGN 7 6. FUELING YOUR HEATER 7 7. OPERATION 8 8.
4 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Figure 5. RMC-KFA120TDLX / RMC-KFA170TDLX MODELS Handle Wheels Wheels Caps Cord Wrap Cord Wrap Screws Hardware Kit Part No : HW-KFA1001 Hardware Kit Part No : HW-KFA1008 Screws(A) Screws(B) Bushing Washers Cotter Pins Front Handle 3.
6 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 4. KEROSENE (1-K) For optimal performance of this heater, it is strongly suggested that 1-K kerosene be used. 1-K kerosene has been refined to virtually eliminate contaminants, such as sulpher. Which can cause a rotten egg odor during the operation of the heater.
7. OPERA TION A.) VENTILATION RISK OF INDOOR AIR POLLUTION/USE HEATER ONLY IN WELL VENTILATED AREAS. Provide a fresh air opening of at least three square feet (2,800 sq. cm) for each 100,000 BTU/Hr. rating. Provide extra fresh air if more heaters are being used.
A.) FUEL TANK FLUSH EVERY 200 HOURS OF OPERATION OR AS NEEDED (SEE STORAGE, PAGE 9) B.) UPPER SHELL REMOVAL -Remove Screw that secure Side Cover. -Push out for arrow direction and extract Side Cover's Bracket from Rectancle Hole and Separate Side Cover(R).
12 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! F.) SPARK PLUG CLEAN AND REGAP EVERY 600 HOURS OF OPERATION OR REPLACE AS NEEDED. -Remove upper shell(See 10 page). -Remove Fan Blade(See 11 Page). -Remove Ignitor Wire from Spark Plug. -Remove Spark Plug from Burner Head using medium phillips screwdriver.
14 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 10. TROUBLE SHOOTING GUIDE 13 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! H.) FUEL FILTER CLEAN OR REPLACE TWICE A HEATING SEASON OR AS NEED. -Remove upper shell(See 10 page). -Remove Fan Blade(See 11 Page).
16 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! RMC-KFA65TDLX RMC-KFA120TDLX / RMC-KFA170TDLX K FA 1 2 0 T- D L X K FA 1 7 0 T- D L X 25" 32.1" 18.5" 25" 36.9" 18.5" H D W M O D E L R M C - K FA 6 5 T D L X R M C - K FA 1 2 0 T D L X R M C - K FA 1 7 0 T D L X B T U / H r .
ACCESSORIES Air Pressure Gauge SP-KFA1011 (all models) Thermostat SP-KFA1010 (all models) FOR TECHNICAL ASSISTANCE SEE YOUR LOCAL RETAILER OR CONTACT US AT: Phone : 1-800-668-5323 18 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 14. P AR TS LIST(RMC-KF A65TDLX Model Only) KEY NO.
20 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 16. P AR TS LIST(RMC-KF A120T/170TDLX Models Only) Fuel Tank Assembly Fuel Gauge Fuel Gauge Cap Fuel Cap Filter Fuel Cap Fuel Filter Assembly Shell .
22 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 17. P AR TS LIST (WHEELS AND HANDLE) 1) RMC-KFA65TDLX MODEL 2) RMC-KFA120T/170TDLX MODELS 1 Handle 3231-0125-00 1 2 Cord Wrap 3231-0056-00 1 3 Hardware Kit HW-KFA1001 1 KEY NO.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.