SAFETY INFORMA TION

  • The water purifier is installed on the cold water pipe, and consequently only the cold water is purified. Note that the hot water is not treated.
  • The purifier must be installed in a location that does not freeze. The temperature when in use must not fall below +2°C. Also avoid hot locations and direct sunlight.
  • Check that the water you want to purify meets the requirements specified in “Technical data”.
  • The water purifier must be placed close to the drinkingwater tap and installed in the cold water pipe with short hoses (< 2 m). Long pure water hoses increase the risk of bacterial growth and should not be used.
  • A pulsating water flow from the water purifier means that the purifier is in standby or that the UV lamp is heating up. Do NOT drink this water.
  • The water pump must be connected to the water purifier; otherwise the purifier will not work correctly.
  • Do not attempt to modify or alter the water purifier in any way at all. This could result in personal injury and/or damage to property. These eventualities are not covered by any warranty.
  • Ensure that hoses and wires do not become kinked or damaged when the water purifier is installed or moved.
  • The water purifier has a switch that disconnects the purifier from electricity when top cover is removed. Do not try to disconnect or shut off this switch when the top cover is removed. This could result in personal injury and is not covered by any warranty.
  • Use only genuine spare parts. See “Consumable parts”.
  • A damaged water purifier must be disconnected.

Use • The water purifier is designed to produce enough water required for a normal household in mobile homes.

  • If the water purifier is not going to be used and exposed for temperatures below 0°C the water purifier has to be stored, see section “Store the water purifier”.
  • The water purifier must never be operated without the filter, except during the disinfection and descaling procedures.
  • Once a month connections should be checked for leakages.
  • If the water purifier contains descaling agents, it must be flushed before pure water may be used.
  • In tanks containing standing water there is a risk of bacterial growth. If any changes in taste or smell are detected, use the trouble-shooting table and try to solve the problem. If the result is unsatisfactory, do not drink the water. Contact your dealer.
  • The system (tank, hoses and water purifier) must be disinfected regularly.
  • At the end of the water purifier’s useful life, disconnect the power to the water purifier using the safety switch in the central electrical unit. Disconnect the electrical wires from the water purifier. Carefully insulate the wires. Make sure that children cannot play with the wires.

Child safety • Do not let children play with the water purifier.

  • Never leave packaging material lying around so that children can play with it.

For information on disposal of your water purifier, contact your local authority or your dealer.

Installation and service • The water purifier must be preceded by a safety switch where the + terminal is disconnected. The disconnection distance is at least 3 mm.

  • The system (tank and hoses) has to be disinfected before the water purifier is installed, see section “Disinfection”.
  • It is important that the purifier is installed standing upright or wall mounted (vertical), horizontal in relation to the floor. This is to ensure that drainage and leakage indication function correctly.
Page 3 of the Dometic Water Purifier (CWP 5311) user manual — USING THE W ATER PURIFIER
Pagina 3 · clicca per ingrandire
Pagina 3

USING THE W ATER PURIFIER

When the water purifier has been installed according to the section ”Installation” it is ready to be used.

Before using the water purifier for the first time:

Dometic Water Purifier (CWP 5311) — USING THE W ATER PURIFIER diagram (page 3)
Fig. 1

1. Check that the filter is in place in the water purifier. 2. Open the shut off valve on the inlet hose. 3. Start the water purifier by pressing the ON/OFF button, see fig. A. The ON/OFF lamp now flashes green, indicating that the UV lamp is heating up in order to purify the water. If the tap is opened dur- ing this heating up phase, a pulsating flow of non- purified water is obtained. 4. Wait until the ON/OFF lamp glows with a steady green light. (Depending on the ambient tempera- ture, this time can vary up to 15 minutes.) 5. In order to flush the filter, open the cold-water tap and let water flush for approx. 1 minute.

The water purifier is ready to be used.

Normal use:

The water purifier is in standby mode and the ON/OFF lamp glows green.

1. Open the cold-water tap. The water purifier automatically starts and pure water is supplied from the purifier. 2. Close the tap.

The water purifier is installed on the cold water pipe, and consequently only the cold water is purified. Note that the hot water is not treated.

If the water purifier has not been in use for 24 hours or longer, flush it for approx. 1 minute before consuming pure water.

Regular Care Listed below are things you need to remember for regular care and maintenance of your water purifier.

  • Check the indicator lamps on the control panel once a week to ensure the water purifier is functioning correctly.

After replacing filter, allow the used filter to drain for a few minutes. It can then be discarded in your ordinary household waste as it does not contain any substances that are hazardous to the environment (assuming the water purifier has been used for the purpose for which it was intended).

  • Keep the outside of the water purifier clean. Wipe off using a damp cloth.
  • Once a month check for leaks in all the connections and hoses to the water purifier.

Do not pour water over the unit and do not use any corrosive or abrasive cleaning products.

  • Be sure to replace filter in time. The level of impurities in your water tank determines the life of the filter. See section “Replacing filter”.
  • The system (tank, hoses and water purifier) must be disinfected regularly, see section “Disinfection”.
  • The water purifier needs to be descaled every 3 months during continuous operation or when the flow has decreased and cannot be restored by replacing the filter, see section “Descaling”.

The filter needs replacing every 6 months, when indicated by the lamps on the control panel, when the water flow has decreased to about half the nor- mal amount or if the water has an unpleasant taste. Take care not to spill any water on the water purifier.

Page 4 of the Dometic Water Purifier (CWP 5311) user manual — E
Pagina 4 · clicca per ingrandire
Pagina 4

Draining Storage below temperature 0°C (32°F) and maintenance requires that the purifier is emptied.

B

Dometic Water Purifier (CWP 5311) — B diagram (page 4)
Fig. 2

1. Check that the water from the drain hose is led out under the caravan. 2. Shut off the water purifier with the ON/OFF button. 3. Disconnect the power supply to the water purifier with the safety switch in the central electrical unit. 4. Press the Release button at the back of the purifier, see fig. B and remove the top cover, see fig. C. 5. Close the shut off valve on the inlet hose. 6. Open the drain valve by lifting up the release button (1) and pulling the valve out (2), see fig. D. 7. Open the filter housing lid by turning it as indicated on the lid, see fig. E. 8. When the water purifier is empty, close the valve by lift- ing up the release button and pushing in the valve (3), see fig. D. Note! Ensure that the edge of the catch really locks the drain valve in the inner position.

Dometic Water Purifier (CWP 5311) — B diagram (page 4)
Fig. 3

D

Dometic Water Purifier (CWP 5311) — D diagram (page 4)
Fig. 4
Dometic Water Purifier (CWP 5311) — D diagram (page 4)
Fig. 5

E

Dometic Water Purifier (CWP 5311) — E diagram (page 4)
Fig. 6
Page 5 of the Dometic Water Purifier (CWP 5311) user manual — G
Pagina 5 · clicca per ingrandire
Pagina 5

Replacing filter The filter needs to be replaced:

- At least every 6 months. - When filter lamp is lit on the control panel. - When the flow has decreased to about half the normal amount. - If the water from the water purifier has an unpleasant taste.

Filter replacement when the filter lamp is lit:

1. Empty the water purifier, see section “Draining”. 2. Fold up the handle and lift out the old filter in accordance with the arrow in figure F. Take care not to drip any water on the water purifier. 3. If the filter housing is dirty, clean the inside of the filter housing carefully with a dishwashing brush.

F

Dometic Water Purifier (CWP 5311) — F diagram (page 5)
Fig. 7

Clean with a dishwashing brush and water only. Do not damage the tube in the centre of the filter housing.

4. Install a new filter. 5. Check that the seal is in place in the lid. Refit filter housing lid by pressing and turning in the opposite direction to the arrows. 6. Refit the top cover and switch on the current to the water purifier using the safety switch in the central electrical unit. 7. Open the shut off valve on the inlet hose and start the purifier by pressing the ON/OFF button. 8. Turn off the filter lamp by pressing in the ON/OFF button, see fig. G, and keeping it pressed until the fil- ter light goes out (approx. 5 seconds). 9. Open the cold-water tap and flush the water purifier for 1 minute.

G

Dometic Water Purifier (CWP 5311) — G diagram (page 5)
Fig. 8

Filter replacement before indication and when the filter lamp is flashing:

1. Replace filter in accordance with point 1-7 above. 2. Switch off the water purifier with the ON/OFF button. 3. Press in the ON/OFF button and keep it pressed. After 3 seconds the filter lamp comes on. 4. Release the button when the filter lamp goes out. 5. Start the water purifier with the ON/OFF button.
Page 6 of the Dometic Water Purifier (CWP 5311) user manual — H
Pagina 6 · clicca per ingrandire
Pagina 6

Replacing UV lamp The UV lamp needs to be replaced when the alarm lamp lights up on the control panel. First check whether the water purifier needs to be descaled instead.

H

Dometic Water Purifier (CWP 5311) — H diagram (page 6)
Fig. 9

Use only a genuine UV lamp from your dealer, to ensure that microbiologically safe water is supplied from the water purifier. See section “Consumable parts”.

1 Disconnect the water purifier by pressing the ON/OFF button. 2. Disconnect the power supply to the water purifier with the safety switch in the central electrical unit. 3. Remove top cover. 4. Remove the insulation above the UV lamp. Remove the socket from the lamp by pulling it straight up, see fig. H 5. Pull out the lamp, see fig. I.

Dometic Water Purifier (CWP 5311) — H diagram (page 6)
Fig. 10

Do not touch the new lamp glass with your fin- gers, as fingerprints reduce the UV intensity.

6. Install a new UV lamp. Carefully press the lamp down until it clicks into place and no longer can be turned. 7. Connect the socket to the new lamp. 8. Refit the insulation. 9. Refit the top cover and switch on the current to the water purifier using the safety switch in the central electrical unit. 10. Start the water purifier with the ON/OFF button. 11. Flush the water purifier for 1 minute.

Return the old UV-lamp to your dealer as it contains mercury, which is very harmful to the environment.

Disinfection In tanks containing standing water there is a risk of bacterial and algae growth. The tank, hoses and water purifier must be disin- fected regularly.

Disinfectant can be purchased from caravan/mobile homes dealers.

1. Empty the water purifier, see section “Draining”. 2. Remove the filter, see fig. F on the previous page. 3. Refit the filter lid and the top cover on the water puri- fier and switch on the current to the water purifier using the safety switch in the central electrical unit. 4. Open the shut off valve on the inlet hose and switch on the water purifier with the ON/OFF button. 5. Disinfect the system according to the instructions on the disinfectant’s packaging. 6. Flush the system according to the instructions on the disinfectant’s packaging. 7. Empty the water purifier again, see section “Draining”. 8. Refit the filter. 9. Refit the filter lid and the top cover on the water puri- fier and switch on the current to the water purifier using the safety switch. 10. Open the shut off valve on the inlet hose. 11. Start the purifier by pressing the ON/OFF button.

Page 7 of the Dometic Water Purifier (CWP 5311) user manual — J
Pagina 7 · clicca per ingrandire
Pagina 7

Descaling procedure The water purifier needs to be descaled every 3 months during continuous use. Descaling agent can be ordered from your dealer, see “Consumable parts”.

J

Dometic Water Purifier (CWP 5311) — J diagram (page 7)
Fig. 11

1. Empty the water purifier, see section “Draining”. 2. Remove the filter. 3. Mix about half a bottle (50 g) of descaling agent in a jug containing 2 dl lukewarm water and stir until fully dissolved. Pour into the filter housing, see fig. J, and fill up with water. 4. Refit the filter housing lid and the top cover and switch on the current to the water purifier using the safety switch in the central electrical unit. 5. Open the shut off valve on the inlet hose and start the purifier by pressing the ON/Off button. 6. Open the cold-water tap and produce water for about 5 seconds so that the agent goes into the purifier. Close the tap.

Water containing descaling agent will be produced. This water must not be drunk.

7. Allow the descaling agent to work for about 10 minutes. 8. Open the cold-water tap for at least 1 minute to flush the water purifier. 9. Empty the water purifier, see section “Draining”. 10. Put the filter back. 11. Refit the filter lid and the top cover and switch on the current to the water purifier using the safety switch in the central electrical unit. 12. Open the shut off valve on the inlet hose and start the purifier by pressing the ON/OFF button. 13. Allow the water purifier to flush pure water to the drain for about 5 minutes. This will remove any traces of descaling agent. 14. Close the tap.

Page 8 of the Dometic Water Purifier (CWP 5311) user manual — Replacing fuse
Pagina 8 · clicca per ingrandire
Pagina 8

Replacing fuse

K

Dometic Water Purifier (CWP 5311) — Replacing fuse diagram (page 8)
Fig. 12 · Replacing fuse

1. Shut off the water purifier with the ON/OFF button. 2. Disconnect the power supply to the water purifier with the safety switch in the central electrical unit. 3. Remove top cover by pressing the Release button at the back of the purifier. Then unhook the top cover at the front. 4. Carefully remove the fuse from the purifier using e.g. a flat screwdriver, see fig. K. 5. Install a new fuse in the water purifier, see section “Consumable parts”. 6. Refit the top cover. 7. Switch on the power supply to the water purifier with the safety switch in the central electrical unit. 8. Start the purifier by pressing the ON/OFF button.

Store the water purifier If the water purifier is not going to be used for an extended period, it should be put into storage.

1. Empty the water purifier, see section ”Draining”. 2. Remove the filter. Let it drain for a few minutes and discard it. (The filter can be discarded with ordinary household waste.) 3. Refit the filter cover and the cover for the purifier.

When the water purifier is going to be used again:

Install a new filter in the filter housing, see section “Replacing fil- ter”, open the shut off valve on the inlet hose and flush the water purifier for approx. 1 minute.

Page 9 of the Dometic Water Purifier (CWP 5311) user manual — SYMPT OM CHECK/REMEDIAL ACTION
Pagina 9 · clicca per ingrandire
Pagina 9

IF THE W ATER PURIFIER STOPS WORKING

Pulsating water flo w

If the water purifier is delivering a pulsating flow, the purifier is in standby or the UV lamp is heating up. The water is not purified. Do NOT drink this water.

Use the trouble-shooting table to rectify the problem that has led to the pulsating flow. Bypass the water purifier If the water purifier is malfunctioning and you need water from the tank, the purifier can be bypassed. Always try to repair the purifier first.

1. Shut the water purifier off by pressing the ON/OFF button. 2. Press the ON/OFF button (approx. 10 seconds) until red lamp lights up on the panel. Release the button. All 3 lamps will flash. 3. Open the cold-water tap. The water purifier will work for 5 seconds, shut down for 5 seconds, work for 5 seconds and so on. This is to remind you that the water is not purified.

The water delivered from the water purifier is not purified. Do NOT drink this water.

T rouble-shooting guide

Dometic Water Purifier (CWP 5311) — T rouble-shooting guide diagram (page 9)
Fig. 13 · T rouble-shooting guide

Lamp off Lamp on Lamp flashing

SYMPT OM CHECK/REMEDIAL ACTION

  • The water purifier is not receiving power. - Is the mobile home’s main power on? - Is the safety switch in the central electrical unit turned on? - Is the water purifier switched on? - Is the top cover in place? - Check that the water purifier is connected to power. - Check the fuse on the caravan’s/mobile home’s distribution board. - Check the fuse in the water purifier. - Check that all the wires are intact.
  • The UV lamp is heating up. If the tap is opened, a pulsating flow of water that has not been purified will be produced. - Wait until the lamp glows with a steady green light. The water purifier is now ready to be used.
  • Time for filter replacement. - Change filter in accordance with section “Replacing filter”.
  • Emergency stop due to filter not having been replaced. - Change filter in accordance with section “Replacing filter”.
  • UV chamber has a lime deposit - Descale the water purifier in accordance with section ”Descaling”.
  • The UV lamp is not working. - Change UV lamp in accordance with section “Replacing UV lamp”.
  • Leakage inside the water purifier. - Check that the filter lid and hoses are properly tightened. - Disconnect the water purifier and empty the leaked water through the hole on the front of the cover. - Connect the water purifier. If leakage occurs again, call Service.
  • The water purifier is bypassed. - The water purifier is not working. If you cannot rectify the problem, call Service.
  • Voltage to the purifier is low. - Is another appliance connected to same circuit at the same time, e.g. TV? Shut down other appliances.
  • Mobile home’s/caravan’s battery level low. - Charge the battery. - Check that the wiring is in accordance with the data in the installation section.
  • The water purifier is in standby or the UV lamp is heating up. - Check the water purifier’s control panel and read off the fault code.

The water has an unpleasant taste and/or odour

  • The purifier has not been used for a long period. - Flush the purifier for 2 minutes. - Change filter according to section “Replacing filter”. - Disinfect the system (tank, hoses and water purifier).

If you are still having problems with your water purifier after having read through and tried the procedures described in the trouble-shoot- ing table, contact your dealer.

Pulsating flow

Page 10 of the Dometic Water Purifier (CWP 5311) user manual — TECHNICAL DA TA
Pagina 10 · clicca per ingrandire
Pagina 10

IF THE W ATER PURIFIER STOPS WORKING

Service and spare parts Before calling service, use the trouble-shooting guide “If the water purifier stops working” to try to rectify the fault yourself. If service is called in to solve a problem that is in this list, there is a risk that you will be responsible for the cost. The same applies if you have used the appliance for a purpose other than that for which it is intended. Note that electrical faults should always be rectified by a certified electrician. Give the appliance’s product and serial numbers according to the data plate (see fig. A). The plate is located on the back of the water purifier. You can record these details here:

PROD.NO SER.NO Purchase date

Dometic Water Purifier (CWP 5311) — IF THE W ATER PURIFIER STOPS WORKING diagram (page 10)
Fig. 14

TECHNICAL DA TA

Data Dimensions- height 340 mm - depth 140 mm - width 290 mm
Weight- on delivery 3.0 kg - filled with water 3.7 kg
Capacity3.8 (±0.8) litres/minute 0.84 (±0.18) gpm (UK)
Inlet pressure0.3-5 bar (30-500 kPa) 5-72 PSI
Working temperature- ambient and water temperature 2 - 43 °C

Electrical data: Connection 12-24 V DC Low voltage protection 9 V Resetting low voltage protection 10 V

Power consumption (excl. pump output): - during purification 10 W - during heating 12 W - in standby 1 W Fuse, slow blow 6.3 A

Pump current, max5 A

Requirements on feed water to water purifier The tank must be filled with municipal water. In standing water (tank water) there is a risk of bacterial growth. The water purifier is intended to purify the tank water.

Turbidity < 7.5 FNU Chlorine 4 mg/litre Organic content < 1 mg/litre

Page 11 of the Dometic Water Purifier (CWP 5311) user manual — Bef ore the water purifier is connected
Pagina 11 · clicca per ingrandire
Pagina 11

Unpacking Check the purifier for any signs of damage and check that no accessories are missing. Any damage, faults or missing parts should be notified to the dealer immediately.

Dometic Water Purifier (CWP 5311) — Placing diagram (page 11)
Fig. 15 · Placing

d

Do not leave packaging material lying around so that children can play with it.

h

Placing

  • The water purifier should be installed close to the cold-water tap so that the pure water hoses are as short as possible, for example underneath the sink or under the couch near the sink.

w

Long pure water hoses (> 2 m) increase the risk of bacterial growth.

B

Dometic Water Purifier (CWP 5311) — B diagram (page 11)
Fig. 16
  • It is important that the purifier is installed standing upright or wall mounted (vertical), horizontal in relation to the floor. This is to ensure that drainage and leakage indication function correctly.
  • It should be easy to inspect the control panel.
  • It should be possible to open the top cover so that the filter container and UV lamp can be accessed.
Dometic Water Purifier (CWP 5311) — B diagram (page 11)
Fig. 17
  • Connections can be routed in any direction from the connection point. Make sure no connections are kinked or damaged. Hoses and wires must not be stretched either. The dimensions of the area required for the water purifier are, see fig. A: w: 340 mm h: 390 mm (for maintenance h: 640 mm) d: 180 mm
1. Mount the bracket (with 4 screws) on the wall or on the floor, see fig. B.
2. Drill a hole in the floor to lead out the drain hose.

D

Dometic Water Purifier (CWP 5311) — D diagram (page 11)
Fig. 18
3. Remove the top cover by pressing the release button on the rear, see fig. C. Lift the rear edge of the top cover and unhook the cover at the front, see fig. D.
4. An adhesive sheet with information in various languages is available as an accessory. Choose the desired language and install in the top cover on the purifier.

Bef ore the water purifier is connected

Tank and hoses have to be disinfected before the water purifier is connected. See section “Disinfection”, points 5-6.

Hole for drainage

Page 12 of the Dometic Water Purifier (CWP 5311) user manual — E
Pagina 12 · clicca per ingrandire
Pagina 12

Electrical connection The electrical connection depends on which water pump is installed; there are two variants:

E

Dometic Water Purifier (CWP 5311) — E diagram (page 12)
Fig. 19
1. Switch-controlled pump. The tap’s knob actuates an electrical switch that connects the pump. 2. Pressure-controlled pump. A pressure sensor on the pump detects that the water pressure drops when the tap is opened, and then connects the pump electrically.

Irrespective of which of the two pump systems is in use, the following applies:

  • The water purifier’s screw terminal is located under the top cover and is marked with number 1-4 in accordance with fig. E.
  • Route the connecting cable with a cross section of 1.5 mm 2 (measure with slide callipers on the stripped conductor, the diameter must be at least approx. 1.4 mm).
  • To avoid excessively large voltage drops, the connecting cables must be kept as short as possible.
  • The purifier’s terminal no. 3-4 must ALWAYS be connected via a fuse and a safety switch to the battery (12-24 V).
  • The purifier’s terminal no. 1-2 is connected to the existing pump.

The water purifier must be preceded by a safety switch where the + terminal is disconnected. The disconnection distance is at least 3 mm.

Dometic Water Purifier (CWP 5311) — E diagram (page 12)
Fig. 20

Be sure to connect the water purifier and the pump to the correct polarity (positive and negative).

1. Connect cable (negative polarity) from the water purifier’s terminal block, no. 1, to the pump’s negative terminal. 2. Connect cable (positive polarity) from the water puri- fier’s terminal block, no. 2, to one side of the tap’s electrical switch. 3. Connect cable from the other terminal on the tap’s electrical switch to the pump’s positive terminal. 4. Connect ground lead (negative polarity) from the cen- tral electrical unit to the water purifier’s terminal block, no. 3. 5. Connect cable (positive polarity) from the pump’s fuse to the water purifier’s terminal block, no. 4.

Dometic Water Purifier (CWP 5311) — E diagram (page 12)
Fig. 21
1. Connect cable (negative polarity) from the water purifier’s terminal block, no. 1, to the pump’s negative terminal. 2. Connect cable (positive polarity) from the water purifier’s terminal block, no. 2, to the pump’s positive terminal. 3. Connect ground lead (negative polarity) from the central electrical unit to the water purifier’s terminal block, no. 3. 4. Connect cable (positive polarity) from the pump’s fuse to the water purifier’s terminal block, no. 4.

Switch-controlled pump · Pressure-controlled pump

Page 13 of the Dometic Water Purifier (CWP 5311) user manual — (B)
Pagina 13 · clicca per ingrandire
Pagina 13

F

Dometic Water Purifier (CWP 5311) — F diagram (page 13)
Fig. 22

The cables from the battery (in the central electri- cal unit) must be protected with a fuse.

The water purifier MUST be connected via the pump in order for the purifier to work correctly.

1. Route the wiring beside the insulation and out at the rear of the product. Screw the tension reliever into place. See fig. F.

Drain connection

G

Dometic Water Purifier (CWP 5311) — Drain connection diagram (page 13)
Fig. 23 · Drain connection
1. Lead out the drain hose throw the hole in the floor, see fig. G. 2. Connect the hose to the drain valve and install the hose clip around the hose. Check that the drain valve is pressed in and locked (catch pressed down). See fig. H.

Water connections The water purifier must be connected to the cold-water pipe. To make maintenance easier, install a shut off valve on the inlet hose.

1. Install a shut off valve on the inlet hose. Leave the valve closed. 2. Connect feed water (from the tank) to the inlet (right) connection on the water purifier, see fig. I (A). 3. Connect the pure water (left connection) from the water purifier to the drinking water tap, see fig. I (B). Install the hose clip.

H

Dometic Water Purifier (CWP 5311) — H diagram (page 13)
Fig. 24

Make sure the hoses are connected in accordance with the above instructions.

Install the water purifier

Dometic Water Purifier (CWP 5311) — Install the water purifier diagram (page 13)
Fig. 25 · Install the water purifier
1. Hook the bracket into the top of the water purifier. Push in the bottom of the water purifier. See fig. J. 2. Refit the top cover on the purifier. 3. Open the shut off valve and switch on the power supply to the water purifier with the safety switch in the central electrical unit.

(B)

Wiring

Page 14 of the Dometic Water Purifier (CWP 5311) user manual — Mo ving the water purifier
Pagina 14 · clicca per ingrandire
Pagina 14

Mo ving the water purifier

J

Dometic Water Purifier (CWP 5311) — Mo ving the water purifier diagram (page 14)
Fig. 26 · Mo ving the water purifier
1. Shut the water purifier off by pressing the ON/OFF button. 2. Empty the water purifier, see section ”Draining”. 3. Remove the filter. 4. Disconnect the electrical connections. 5. Disconnect all the hoses. 6. Unhook the water purifier from the bracket. 7. Reconnect the electrical cables. 8. Reconnect the hoses.

When the water purifier is going to be used again, install in accordance with section “Installation”. Do not forget to insert a new filter in the filter housing, see section “Replacing filter”.

Fai una domanda su Dometic Water Purifier (CWP 5311)

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Dometic Water Purifier (CWP 5311)

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Dometic Water Purifier (CWP 5311) manuale in PDF

117 pagine·2.9 MB·Impianto idrico·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…