Dodge Engineering & Controls, Inc. Toll Free (877) 334-2875 Fax: (978) 244-1422 Installation EN221 and EN310 Non-Spring Return Electronic Actuators EA0662R1 a f d g c e b PUSH Figure 1. Parts of the EN221 and EN310 Actuators. a. Actuator b. U-bolt shaft adapter c.
Dodge Engineering & Controls, Inc. Toll Free (877) 334-2875 Fax: (978) 244-1422 Installation EN221 and EN310 Non-Spring Return Electronic Actuators For Tandem Applications • The direction of rotation switches must be set identically on both actuators ac cording to the cloc kwise or counterc lockwise rotation of the damper shaft.
Dodge Engineering & Controls, Inc. Toll Free (877) 334-2875 Fax: (978) 244-1422 Installation EN221 and EN310 Non-Spring Return Electronic Actuators PUSH EA0869R1 a 2 3 4 3 2 a e b d d SHAFT ADAPTE.
Dodge Engineering & Controls, Inc. Toll Free (877) 334-2875 Fax: (978) 244-1422 Installation EN221 and EN310 Non-Spring Return Electronic Actuators Manual Override To move the damper blades without power present, do the following: 1. Hold down the PUSH button.
Dodge Engineering & Controls, Inc. Toll Free (877) 334-2875 Fax: (978) 244-1422 Installation EN221 and EN310 Non-Spring Return Electronic Actuators 90 90 EA0676R1 PUSH Figure 12. 4. Determine the angle of rotation for the damper blade shaft. Subtract that amount from 90°.
Dodge Engineering & Controls, Inc. Toll Free (877) 334-2875 Fax: (978) 244-1422 Installation EN221 and EN310 Non-Spring Return Electronic Actuators Factory setting: Switch A 5° Switch B 85° To change the settings of A and B: • Make sure the actuator is i n the 0 position.
Dodge Engineering & Controls, Inc. Toll Free (877) 334-2875 Fax: (978) 244-1422 Installation EN221 and EN310 Non-Spring Return Electronic Actuators Settings: Offset U0 = 2, Span: ∆ U = 16V Umin = minimum control si gnal Umax = maximum control signal 100 0 ∆ U (16 V) Y U (v) Y S (%) 21 8 10 U min U max 50 U o EA0412R1 Figure 19.
Dodge Engineering & Controls, Inc. Toll Free (877) 334-2875 Fax: (978) 244-1422 Installation EN221 and EN310 Non-Spring Return Electronic Actuators Three-Position Control (24 VAC) M A B S1 S4 S2 S3 S5 S6 1 6 7 PL0009R1 Figure 21. Table 1. Three-Pos ition Control 24 VAC.
Dodge Engineering & Controls, Inc. Toll Free (877) 334-2875 Fax: (978) 244-1422 Installation EN221 and EN310 Non-Spring Return Electronic Actuators Start-Up/Commissioning Three-Position Control, 24 VAC 1. Check that the wires are conne cted correctly.
Dodge Engineering & Controls, Inc. Toll Free (877) 334-2875 Fax: (978) 244-1422 Installation EN221 and EN310 Non-Spring Return Electronic Actuators Modulating Control, 24 VAC 1. Check that the wires are conne cted correctly. 2. Check that the offset (start point) and span are set correctly, if used.
Dodge Engineering & Controls, Inc. Toll Free (877) 334-2875 Fax: (978) 244-1422 Installation EN221 and EN310 Non-Spring Return Electronic Actuators Dimensions 9 5 ˚ 1-11/32 34 mm 1-11/32 34 mm min. 2-1/2 in. 60 mm min. 1/4 in. 7 mm min. 8 in. 200 mm 3-3/8 in.
Dodge Engineering & Controls, Inc. Toll Free (877) 334-2875 Fax: (978) 244-1422 Installation EN221 and EN310 Non-Spring Return Electronic Actuators EA0768R1 1 13/16 in. 46 mm 3 5/8 in. 92 mm 9 in. 230 mm 3 1/8 in. 78 mm 1/2 in. 13.5 mm ASK73.1U 985-006 Figure 24.
Dodge Engineering & Controls, Inc. Toll Free (877) 334-2875 Fax: (978) 244-1422 Installation EN221 and EN310 Non-Spring Return Electronic Actuators Sizing Actuators for Damper Applications The number of actuators required depe nds on several fact ors.
Dodge Engineering & Controls, Inc. Toll Free (877) 334-2875 Fax: (978) 244-1422 Installation EN221 and EN310 Non-Spring Return Electronic Actuators ACCESSORIES NOTE: The auxiliary switches and/or the control signal adjustment cannot be added in the field.
Dodge Engineering & Controls, Inc. Toll Free (877) 334-2875 Fax: (978) 244-1422 Installation EN221 and EN310 Non-Spring Return Electronic Actuators EA0496R1 Figure 5. Tandem Mount Bracket. ASK73.1 This bracket prov ides an extended anti- rotation pin that allows two 3-position EN 310 actuators to directly drive a single damper shaft.
Dodge Engineering & Controls, Inc. Toll Free (877) 334-2875 EN221 and EN310 Non-Spring Return Electronic Actuator Installation Guide General Installa tion ............................................................................................
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Dodge EN310 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Dodge EN310 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Dodge EN310 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Dodge EN310 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Dodge EN310, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Dodge EN310.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Dodge EN310. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Dodge EN310 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.