Nailer/Stapler Operation Manual MG-NS2X4A 7/16/99 This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. PLEASE READ THIS MANUAL. DeVilbiss Air Power Company • 213 Industrial Drive • Jackson, TN 38301-9615 Specifications MODEL NO.
PAGE 2 Page Tool Specifications ................................................................ Front Cover Table of Contents ................................................................................... 2 Limited Warranty .....................
PAGE 3 All merchandise manufactured by DeVilbiss Air Power Company/ExCell Manufacturing is warranted to be free of defects in workmanship and material which occur during the first year from the date of purchase by the original purchaser (initial user).
PAGE 4 HAZARD TO LOOK FOR Compressed Gas Excessive Operating Pressure Unsuitable Cleaning Solvents WHAT COULD HAPPEN Oxygen will react with oil in tool caus- ing an explosion. Flammable gases will ignite from sparking and cause the tool to explode, resulting in serious injury or death.
PAGE 5 Risk of head injury. WHAT COULD HAPPEN Metal fragments, fasteners, or other material could be projected against head or into eyes resulting in serious injury or property damage. Contin- ued exposure to an operating tool can result in permanent hearing dam- age.
PAGE 6 Risk from flying objects. WHAT COULD HAPPEN Fasteners could ricochet or be propelled causing serious injury or property damage. When working along edges or next to voids in work surface, the co.
PAGE 7 Do not store the tool in cold weather. Frost or ice can form on the operating valves or mechanisms and the tool may not operate correctly. In cold weather operation (near or below freezing), DO NOT USE a permanent antifreeze such as ethylene glycol for a cold weather lubricant.
PAGE 8 Always connect the Female Quick Cou- pler to the air hose. Never connect the Female Quick Coupler to the tool. Never carry the tool by the hose or pull the hose to move the tool or a com- pressor. Keep hoses away from heat, oil, and sharp edges.
PAGE 9 NAILER FEMALE QUICK COUPLER MALE QUICK CONNECTOR OILER FILTER RECOMMENDED HOOK-UP The following illustration shows the proper hook-up which will help prolong the life of the Tool.
PAGE 10 OPERATING A CONTACT TRIP TOOL: 1. Requires finger to be off the trigger and the nose of the Tool to be placed on the work surface. 2. The contact trip safety mechanism is then depressed against the work surface and the trigger pulled to drive a fastener.
PAGE 11 Handle the tool carefully. Respect the tool as a working implement and always as- sume the tool contains fasteners: a. Never use the tool as a toy and engage in horseplay. b. Never aim or point the tool at any- one. The tool may contain fasteners.
PAGE 12 4. Push release button (if equipped) and slide feeder shoe forward. Protect your eyes and ears. Wear Z87 safety glasses with side shields. Wear hearing protection. Employers and users are responsible for ensuring the user or anyone near the tool uses the prescribed safety equipment.
PAGE 13 Disconnect tool from air compressor before adjusting, clearing jams, servicing, relocating and during non-operation. FASTENER JAMMED IN FASTENER DISCHARGE AREA: 1. Disconnect tool from air hose. 2. NF2502X4, NB1252X4, NB2002X4, NBSNC2X4 Release the magazine latch to open the magazine.
PAGE 14 FASTENER JAM INSIDE MAGAZINE : 1. Disconnect tool from air hose. 2. NF2502X4, NB1252X4, NB2002X4, NBSNC2X4 Release the magazine latch to open the magazine. Feeder Magazine Latch SNC1002x4 Pull feeder shoe back into "locked" position.
PAGE 15 PROBLEM Air leaking at trigger valve area. Air leaking through the exhaust deflector. Tool fails to drive fastener. Tool runs slow or has loss of power. SOLUTION Seals must be replaced & operation of Contact trip must be checked. On the NBSNC2x4 contact *AWSC for correct part.
PAGE 16 SOLUTION Replace feed pawl. Contact an *AWSC Replace feed pawl spring. Fasteners recommended for tool must be used. Replace with undamaged fasteners. Set platform to correct height. Adjust air pressur e to the correct PSI for that particular model nailer/stapler .
PAGE 17 NF2502X4 1/4" NPT INLET PLUG (AC100) FINISH NAIL FASTENERS 6 & 7MM COMBINATION CRESCENT WRENCH 3 4 5mm ALLEN WRENCHES FINISH NAILER LUBRICATING OIL SAFETY GLASSES 1 1 / 2 ” 1 ” 1 .
PAGE 18 SNC1002X4 NARROW CROWN STAPLE FASTENER 1/4" NPT INLET PLUG (AC100) LUBRICATING OIL NARROW CROWN STAPLER 3 & 4 ALLEN WRENCHES SAFETY GLASSES Tool 2X4 Part Number Description Qty per Bo.
PAGE 19 NB2002X4 LUBRICATING OIL 1/4" NPT INLET Plug (AC100) BRAD NAILER BRAD NAIL FASTENERS 4 3 ALLEN WRENCHES 5/8" SAFETY GLASSES Tool 2X4 Part Number Description Qty per Box Steel Driver .
PAGE 20 NB1252X4 LUBRICATING OIL 1/4" NPT INLET PLUG (AC100) BRAD NAIL FASTENERS BRAD NAILER 4MM 3MM ALLEN WRENCHES SAFETY GLASSES Tool 2X4 Part Number Description Qty per Box Steel Driver Series.
PAGE 21 NBSNC2X4 2X4 SIGNATURE SAFETY GLASSES LUBRICATING OIL 4MM 3MM ALLEN WRENCHES COMBINATION BRAD NAILER/ NARROW CROWN STAPLER NARROW CROWN STAPLE & BRAD NAIL FASTENERS 1/2" 3/4" 1&q.
PAGE 22 REP AIR KITS A V AILABLE K-0521 T op Repair Kit K-0522 Bottom Repair Kit NF2502X4 K-1664 Driver Blade Kit K-0523 T rigger Repair Kit SNC1002X4 and NB1252X4 K-0525 T op Repair Kit K-0526 Bottom.
PAGE 23 REP AIR KITS A V AILABLE K-0517 T op Repair Kit K-0518 Bottom Repair Kit NB2002X4 K-1850 Driver Blade Kit K-0519 T rigger Repair Kit NBSNC2X4 B340-06 T op Repair Kit B232-23 Bottom Repair Kit .
Nailer/Stapler Operation Manual Call our T oll Free Number 1-800-888-2468, Ext 2, then 1, to obtain the location of the nearest Authorized Service Center for ordering r epair parts and for warranty repairs.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il DeVillbiss Air Power Company NBSNC2X4 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del DeVillbiss Air Power Company NBSNC2X4 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso DeVillbiss Air Power Company NBSNC2X4 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul DeVillbiss Air Power Company NBSNC2X4 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il DeVillbiss Air Power Company NBSNC2X4, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del DeVillbiss Air Power Company NBSNC2X4.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il DeVillbiss Air Power Company NBSNC2X4. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo DeVillbiss Air Power Company NBSNC2X4 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.