MODEL NO. F AC1025 DeVilbiss Air Power Company • 213 Industrial Drive • Jackson, TN 38301-9615 MGP-FAC1025-2 9/18/99 OWNERS MANUAL FOR PERMANENTL Y LUBRICA TED AIR COMPRESSOR (For Home Use Only) MODEL NO.
2 — ENG T ABLE OF CONTENTS SAFETY GUIDELINES - DEFINITIONS Information for preventing damage to equipment. This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS .
3 — ENG LIMITED W ARRANTY ONE YEAR FROM DA TE OF PURCHASE All merchandise manufactured by DeVilbiss Air Power Company/ExCell Manufacturing is warranted to be free of defects in workmanship and material which occur during the first year from the date of purchase by the original purchaser (initial user).
4 — ENG RISK OF BURSTING RISK OF ELECTRIC SHOCK RISK OF EXPLOSION OR FIRE Ai r T an k • T H E F OLL OW IN G CONDITION S COUL D lead to a we ak ening of the tank, and RES UL T I N A V IOLE N T T AN K EX PL OS IO N: 1. FAILURE TO PROPERL Y DRAIN condensed W A TER FROM THE T ANK , causing rust and thinning of the tank steel.
5 — ENG • The COMPRESSED AIR from your compressor IS NOT SAFE FOR BREA THING! The air stream may contain carbon monoxide or other toxic vapors, or particles from the tank or other components. • SPRA YED MA TERIALS such as paint, paint solvents, paint remover , insecticides, weed killers, etc.
6 — ENG GLOSSAR Y which the motor automatically re-starts is called "cut-in pressure." CUT-OUT PRESSURE: When you turn on your air com- pressor and it begins to run, air pressure in the air tank begins to build. It builds to approximately 125 PSI before the motor automatically shuts off .
7 — ENG DESCRIPTION OF OPERA TION Air Compressor Pump: To compress air, the piston moves up and down in the cylinder. On the downstroke, air is drawn in through the intake valves. The exhaust valves remain closed. On the upstroke of the piston, air is compressed.
8 — ENG Break-in Procedures INST ALLA TION AND BREAK-IN PROCEDURES GROUNDING INSTRUCTIONS Additional Regulators and Controls Since the air tank pressure is usually greater than that which is needed, a regulator is employed to control the air pressure ahead of any individual air driven device.
9 — ENG OPERA TING PROCEDURES 1. Before attaching air hose or accessories, make sure the OFF/AUTO lever is set to “OFF” and the air regulator or shut-off valve is closed. 2. Attach hose and accessories. When you are finished: 6. Set the “OFF/AUTO” lever to “OFF”.
10 — ENG Defective air tank. CORRECTION Excessive tank pressure - safety valve pops off. Pressure switch does not shut off mo- tor when compressor reaches “cut- out” pressure. Move the pressure switch lever to the “OFF” posi- tion. If the outfit doesn’t shut off, unplug.
11 — ENG TROUBLESHOOTING GUIDE (Continued) CORRECTION CAUSE Possible defect in safety valve. Knocking Noise Compressor is not supplying enough air to operate acces- sories. Prolonged excessive use of air. Decrease amount of air usage. Hole in hose. Remove and clean, or replace.
12 — ENG P AR TS LIST AIR HOSE REGULATOR SAFETY VALVE TANK PRESSURE GAUGE PRESSURE SWITCH AIR HOSE OUTLET PRESSURE GAUGE COMPRESSOR ASSEMBLY AIR TANK DRAIN VALVE (Not Shown) CHECK VALVE (Not Shown) ISOLATOR DESCRIPTION PART NUMBER AIR CHUCK ........
13 — ENG AIR COMPRESSOR DIAGRAM.
14 — ENG P ARTS LIST KEY NO. PART NUMBER DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 21 22 25 ----- CAC-1196 CAC-1212 CAC-1199 CAC-4323 SSG-8169 AC-0161 ----- ----- ----- N/A CAC-1342 CAC-1213 AC-0470 AC-0471 ----- ----- NOT ILLUSTRATED H-2099 Screw #10-24 x 7/8 LG.
15 — ENG NOTES.
PERMANENTL Y LUBRICA TED AIR COMPRESSOR MODEL NO. F AC1025 Attach Sales Receipt here. Retain Original Sales Receipt as Proof of Purchase for Warranty Repair Work. Call our T oll Free Number 1-800-888-2468, Ext 2 , then 1, to obtain the location of the nearest Authorized Service Center for ordering repair parts and for warranty repairs.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il DeVillbiss Air Power Company MGP-FAC1025-2 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del DeVillbiss Air Power Company MGP-FAC1025-2 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso DeVillbiss Air Power Company MGP-FAC1025-2 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul DeVillbiss Air Power Company MGP-FAC1025-2 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il DeVillbiss Air Power Company MGP-FAC1025-2, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del DeVillbiss Air Power Company MGP-FAC1025-2.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il DeVillbiss Air Power Company MGP-FAC1025-2. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo DeVillbiss Air Power Company MGP-FAC1025-2 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.