Air Compr essor Permanently Lubricated ● Portable OPERA TOR’S MANUAL SAFETY ● ASSEMBL Y ● OPERA TION ● MAINTENANCE ● STORAGE ● TROUBLESHOOTING ● ESP AÑOL ● FRANÇAIS D26368 Rev .
2- ENG D26368 T ABLE OF CONTENTS SAFETY GUIDELINES-DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . .2 IMPORT ANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . .2-7 ON-RECEIPT INSPECTION . . . . . . . . . . . . . . . . .
3- ENG D26368 IMPORT ANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this pr oduct could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment.
4- ENG D26368 WARNING: Risk of Bursting Air T ank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury .
5- ENG D26368 HOW TO PREVENT IT WHA T CAN HAPPEN WARNING: Risk to Br eathing WARNING: Risk of Electrical Shock HOW TO PREVENT IT WHA T CAN HAPPEN HAZARD HAZARD Y our air compressor is powered by electricity . Like any other electrically powered device, If it is not used pr operly it may cause electric shock.
6- ENG D26368 HOW TO PREVENT IT WHA T CAN HAPPEN WARNING: RISK OF BURNS T ouching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation.
7- ENG D26368 Review and understand all instructions and war nings in this manual. Become familiar with the operation and controls of the air compr essor . Keep operating area clear of all persons, pets, and obstacles. Keep children away fr om the air compressor at all times .
8- ENG D26368 GLOSSAR Y Become familiar with these terms before operating the unit. CFM : Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measur e of air delivery . PSIG: Pounds per square inch gauge; a unit of measur e of pressur e.
9- ENG D26368 ASSEMBL Y Assembly for “Pancake” units T ools Requir ed for Assembly 1 - 3/8” socket or nut driver 1. Carefully place unit on side opposite of controls. 2. Using a 3/8 inch socket or nut driver remove the scr ews attaching the unit to the shipping pallet.
10- ENG D26368 Rubber Feet Screw Nut Wheel Shoulder Bolt Assembly for “V ertical” units T ools Requir ed for Assembly 1 - 9/16” socket or open end wrench 1 - 1/2” socket or open end wrench 1. Remove all packaging leaving the air compressor on the pallet.
Assembly for “Horizontal” units T ools Requir ed for Assembly 1 - 9/16” socket or open end wrench 1 - 3/8” socket or open end wrench 1 - 1/2” socket or open end wrench 1. (if equipped) T o make installation easier , submer ge handle grip into warm soapy water .
12- ENG D26368 INST ALLA TION GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK. In the event of a short circuit, gr ounding reduces the risk of shock by pr oviding an escape wire for the electric curr ent. This air compressor must be properly gr ounded.
13- ENG D26368 Extension Cords Using extension cords is not r ecommended. The use of extension cords will cause voltage to drop r esulting in power loss to the motor and overheating. Instead of using an extension cord, incr ease the working reach of the air hose by attaching another length of hose to its end.
14- ENG D26368 OPERA TION Description of Operation Become familiar with these controls befor e operating the unit. On/Auto/Off Switch : T urn this switch ON to provide automatic power to the pr essure switch and OFF to remove power at the end of each use.
15- ENG D26368 Drain V alve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use. Cooling System (not shown) : This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan.
16- ENG D26368 How to Start: 1. T urn the On/Auto/Off lever to “ AUTO ” and allow tank pressur e to build. Motor will stop when tank pressur e reaches “ cut-out ” pr essure. 2. Pull the regulator knob out and turn clockwise to increase pr essure.
17- ENG D26368 MAINTENANCE Customer Responsibilities Daily or after each use Before each use ● ● Y early ● 1 1- more fr equent in dusty or humid conditions Check Safety V alve Drain T ank Air Filter Unit cycles automatically when power is on.
18- ENG D26368 SERVICE AND ADJUSTMENTS Unit cycles automatically when power is on. When doing Maintenance, you may be exposed to voltage sources, compressed air or moving parts. Personal injuries can occur . Befor e performing any Maintenance or repair , unplug the compr essor and bleed off all air pressur e.
7. Unscrew the check valve (turn counterclockwise) using a 7/8 ” open end wr ench. Note the orientation for reassembly . 8. Using a screwdriver , car efully push the valve disc up and down.
20- ENG D26368 STORAGE Before you stor e the air compressor , make sur e you do the following: 1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary . 2. Set the On/Auto/Off lever to “ OFF ” .
21- ENG D26368 TROUBLESHOOTING Performing repairs may expose voltage sour ces, moving parts or compressed air sour ces, moving parts or compressed air sour ces. Personal injury may occur . Prior to attempting any repairs, unplug the air compr essor and bleed off all air tank air pressur e.
22- ENG D26368 PROBLEM CAUSE CORRECTION It is normal for “ some ” pressur e drop to occur . If there is an excessive amount of pressur e drop when the accessory is used, adjust the regulator following the instructions in the “ Description of Operation ” paragraph in the “ Operation Section.
23- ENG D26368 Regulator will not shut off air outlet. Damaged regulator Replace PROBLEM CAUSE CORRECTION Motor will not run. Fuse blown, circuit br eaker tripped.
24- ENG D26368 LIMITED W ARRANTY DeVilbiss Air Power Company warrants to the original purchaser who uses the pr oduct in a consumer application (personal, residential or household usage) that all products cover ed under this warranty are free fr om defects in material and workmanship for one year from the date of purchase.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il DeVillbiss Air Power Company D26368 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del DeVillbiss Air Power Company D26368 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso DeVillbiss Air Power Company D26368 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul DeVillbiss Air Power Company D26368 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il DeVillbiss Air Power Company D26368, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del DeVillbiss Air Power Company D26368.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il DeVillbiss Air Power Company D26368. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo DeVillbiss Air Power Company D26368 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.