Manuale d’uso / di manutenzione del prodotto VMH10TP del fabbricante Desa
Vai alla pagina of 32
Save this manual for future reference. OWNER’S OPERA TION AND INST ALLA TION MANUAL VENT -FREE PROP ANE/LP GAS COMP ACT CLASSIC HEARTH FIREPLACE ® 10,000 Btu/Hr with Thermostat ® Shown with Op.
2 103669 CONTENTS SECTION PAGE Safety Information continues on next page Safety Information ................................................................................... 2 Product Identification ..................................................
3 103669 SAFETY INFORMA TION Continued WARNING ICON G 001 W ARNINGS Continued WARNING: Any change to this fireplace or its controls can be dangerous. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
4 103669 PRODUCT IDENTIFICA TION LOCAL CODES Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also known as NFPA 54*. *Available from: American National Standards Institute, Inc.
5 103669 ASSEMBL Y ASSEMBLING FIREPLACE Tools Required: Phillips screwdriver, 5/16" hex wrench, and slotted screwdriver Installing Log 1. Remove back log, branch, and hood from log box. Discard protective packaging. 2. Remove two shipping screws above screen (see Figure 2).
6 103669 AIR FOR COMBUSTION AND VENTILA TION WARNING ICON G 001 W ARNING This heater shall not be installed in a confined space unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
7 103669 AIR FOR COMBUSTION AND VENTILA TION Continued DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space.
8 103669 AIR FOR COMBUSTION AND VENTILA TION Continued Figure 4 - Ventilation Air from Inside Building Shown with Optional Mantel WARNING ICON G001 W ARNING If the area in which the heater may be oper.
9 103669 AIR FOR COMBUSTION AND VENTILA TION Continued Figure 5 - Ventilation Air from Outdoors Shown with Optional Mantel Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor.
10 103669 INST ALLA TION CHECK GAS TYPE Use only propane/LP gas. If your gas supply is not propane/LP, do not install fire- place. Call the dealer where you bought your fireplace for the proper type fireplace. INSTALLATION ITEMS Before installing fireplace, make sure you have the items listed below.
11 103669 WARNING ICON G001 CAUTION This fireplace creates warm air currents. These currents move heat to wall surfaces next to fireplace. Installing fireplace next to vinyl or cloth wall coverings or operating fireplace where impurities in the air (such as tobacco smoke) exist, may discolor walls.
12 103669 INST ALLING Continued 36 5/8" 25 7/8" 51 3/4" 26 7/8" Figure 9 - Rough Opening for Installing in Corner 2. An optional blower accessory is available (see Accessories , page 29). There are three options for connecting blower to electrical source.
13 103669 INST ALLING Continued Continued 6. Attach flexible gas line to fireplace gas regulator. See Connecting Fireplace to Gas Supply, page 17. 7. If the optional blower has been installed connect blower to electrical source. Options one and two: Route blower electrical cord through side or rear access door of fireplace.
14 103669 INST ALLING Continued Figure 12 - Attaching Brass Trim to Fireplace Shoulder Screws Assembled Brass Trim OPTIONAL MANTEL INSTALLATION Note: Refer to instructions provided with the mantel for assembly instructions. Refer to instructions below for system installation.
15 103669 Attaching Wood Base to Solid Floor For attaching base to solid floors (concrete or masonry) Note: Floor anchors and mounting screws are in hardware package. The hardware package is provided with fireplace. 1. Drill holes at marked locations using 5/16" drill bit.
16 103669 CONNECTING T O GAS SUPPL Y Figure 16 - External Regulator with Vent Pointing Down NOTICE A qualified service person must connect fireplace to gas supply. Follow all local codes. WARNING ICON G 001 CAUTION Never connect fireplace directly to the propane/LP supply.
17 103669 Continued CONNECTING T O GAS SUPPL Y Continued Figure 18 - Removing Branch Support From Fireplace CONNECTING FIREPLACE TO GAS SUPPLY Installation Items Needed • Phillips screwdriver • sealant (resistant to propane gas, not provided) 1. Remove fireplace screen.
18 103669 CHECKING GAS CONNECTIONS PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1/2 PSIG 1. Disconnect fireplace and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage fireplace regulator.
19 103669 ON POSITION OFF POSITION Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Figure 20). 2. Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve. 3. Check all joints from propane/LP supply tank to manual shutoff valve (see Figure 21).
20 103669 OPERA TING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTING Continued WARNING ICON G 001 W ARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. LIGHTING INSTRUCTIONS 1.
21 103669 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 20. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise C-clockwise to the PILOT position.
22 103669 INSPECTING BURNER Thermocouple Pilot Burner Figure 24 - Correct Pilot Flame Pattern Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 24 shows a correct pilot flame pattern. Figure 25 shows an incorrect pilot flame pattern.
23 103669 Thermocouple Pilot Burner Figure 25 - Incorrect Pilot Flame Pattern If pilot flame pattern is incorrect, as shown in Figure 25 • turn fireplace off (see To Turn Off Gas to Appliance , page 22). • see Troubleshooting , pages 24 through 27.
24 103669 CLEANING AND MAINTENANCE ODS/PILOT AND BURNER • Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean. CABINET Air Passageways • Use a vacuum cleaner or pressurized air to clean. Exterior • Use a soft cloth dampened with a mild soap and water mixture.
25 103669 Continued REMEDY 1. Turn on gas supply or open manual shutoff valve 2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat ig- niting operation until air is removed 5.
26 103669 TROUBLE- SHOOTING Continued OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Slight smoke or odor during initial operation Fireplace produces a whistling noise when burner is lit POSSIBLE CAUSE 1.
27 103669 TROUBLE- SHOOTING Continued WARNING ICON G 001 W ARNING If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
28 103669 TECHNICAL SER VICE You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323-5190. SPECIFICA TIONS SER VICE HINTS REPLACEMENT P ARTS Input Rate 10,000 Btu/Hr Type Gas Propane/LP Only Ignition Piezo Pressure Regulator Setting 8.
29 103669 ACCESSORIES Purchase these fireplace accessories from your local dealer. If they cannot supply these accessories call DESA International’s Sales Department at 1-800-458-2472 for referral information. You can also write to the address listed on the back page of this manual.
30 103669 12-1 12-2 23 29 32 36 37 13 7 33 11 8 10 8 7 30 3 1 2 9 17 19 6 22 31 21 40 27 38 38 16 15 18 24 28 5 34 26 25 20 42 35 12 24 12-1 25 14 4 39 41 VMH10TP.
31 103669 P ARTS LIST This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 28 of this manual.
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 103669-01 REV. B 08/97 LIMITED WARRANTY VENT-FREE PROPANE/LP GAS COMPACT CLASSIC HEARTH FIREPLACE DESA International warrants this.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Desa VMH10TP è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Desa VMH10TP - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Desa VMH10TP imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Desa VMH10TP ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Desa VMH10TP, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Desa VMH10TP.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Desa VMH10TP. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Desa VMH10TP insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.