DEL T A ELECT RONICS, INC. 1 Nov ., 2006 Rev . 1D www .delt aww.co m RoHS Compliant Small Form Factor Pluggable T ransceiver for Fiber Channel with Digit al Diagno stic Monitoring Function FEATURES z Compliant with SFP T ranscei ver SFF-8472 MSA specificat ion z LCP-2125A4EDR complian t with t he 2.
DEL T A ELECT RONICS, INC. 2 Nov ., 2006 Rev . 1D www .delt aww.co m Absolute Maximum Ratings Parameter Symbol Min. T y p. Max. Unit Note S torage T emperature T s -40 85 ºC Supply V oltage V CC 0 5 V Recommended Operating Con ditions Parameter Symbol Min.
DEL T A ELECT RONICS, INC. 3 Nov ., 2006 Rev . 1D www .delt aww.co m Optical Characteristics (V CC =3.3V ± 5%, Data Rate=2.125Gb/sec, PRBS=2 7 -1 NRZ ) Parameter Symbol Min.
DEL T A ELECT RONICS, INC. 4 Nov ., 2006 Rev . 1D www .delt aww.co m SFP Transceiver Electrical Pad Layout Pin Function Definitions Pin Num. Name Function Plug Seq.
DEL T A ELECT RONICS, INC. 5 Nov ., 2006 Rev . 1D www .delt aww.co m Notes: 1) TX Fault is an open collector/drain output, which should be pulled up with a 4.7K – 10K resisto r on the host board. Pull up voltag e between 2.0V and VccT, R+0.3V. Wh en high, output indicates a laser fault of some kind.
DEL T A ELECT RONICS, INC. 6 Nov ., 2006 Rev . 1D www .delt aww.co m Recommend Circuit Schematic Laser Diode Photo D iode 1uH 1uH 0.1uF 10uF 0.1uF 0.01uF 0.01uF 0.01uF 0.01uF 0.1uF 10uF RES1 RES1 100 Ohms* RES1 RES1 RES1 10k Ohms 100 Ohms VCC Protocol Vcc SerDes IC Protocol IC PLD / PAL Mod_def 2 Mod_def 1 Mod_def 0 3.
DEL T A ELECT RONICS, INC. 7 Nov ., 2006 Rev . 1D www .delt aww.co m Package Outline Drawing.
DEL T A ELECT RONICS, INC. 8 Nov ., 2006 Rev . 1D www .delt aww.co m SFP timin g p arameters f or SFP management Parameter Symbol Min. Max. Unit No te TX_DISABLE Assert time t_off 10 μ sec 1 TX_DISAB.
DEL T A ELECT RONICS, INC. 9 Nov ., 2006 Rev . 1D www .delt aww.co m Enhanced Digit al Diagnostic Interface The memory map in the following d escribes an extension to th e memory map defined in SFP MSA.
DEL T A ELECT RONICS, INC. 10 Nov ., 2006 Rev . 1D www .delt aww.co m EEPROM Serial ID Memory Content s (2-Wire Address A0h) Address Hex ASCII A ddress Hex A S CII Address Hex ASCII 00 03 43 PN 86 DC .
DEL T A ELECT RONICS, INC. 1 1 Nov ., 2006 Rev . 1D www .delt aww.co m 8) Byte 84-91: Date code 9) Byte 95: Check sum of byt es 64-94 10) Byte 128 to 25 5 had been set hex 00 Digit al Diagnostic Monitoring Interface Alarm and W arnin g Thresholds (2-Wire Address A2h) Address # Bytes Name Va l u e ( D e c .
DEL T A ELECT RONICS, INC. 12 Nov ., 2006 Rev . 1D www .delt aww.co m P S : Sensitivity optical power of receiver 5) Byte 95 contai ns the low order 8b its of sum of bytes 0-94 6) St at e/ Control Bit.
DEL T A ELECT RONICS, INC. 13 Nov ., 2006 Rev . 1D www .delt aww.co m 1) T emperature is measured internal to the tra nsceiver . 2) V oltage is measured internal to the transc eiver .
DEL T A ELECT RONICS, INC. 14 Nov ., 2006 Rev . 1D www .delt aww.co m Ordering information for SFP modules LCP-2125X 1 X 2 X 3 X 4 X 5 X 6 X 1 : Fiber A : Multi-mode 850nm X 4 : Digital Diagnostic Function D : DDM series, with digital diagnostic function X 2 : Power Supply V oltage and SD Lev el 4 : 3.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Delta Electronics LCP-2125 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Delta Electronics LCP-2125 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Delta Electronics LCP-2125 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Delta Electronics LCP-2125 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Delta Electronics LCP-2125, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Delta Electronics LCP-2125.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Delta Electronics LCP-2125. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Delta Electronics LCP-2125 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.