Manuale d’uso / di manutenzione del prodotto Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI del fabbricante Delta Electronics
Vai alla pagina of 14
OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 1 Revision: S3 12/20/2007 www .delt aww.c om 1.25Gbp s Up stream/1.25Gbp s Downstream Intelligent GE-PON ONU T ransceiver FEATURES z RoHS compliant z Digit a l Diagnostic SFF-8472 MSA compliant z Support extended operating Case temperatu re from -20 ºC to +85 ºC z IEEE802.
OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 2 Revision: S3 12/20/2007 www .delt aww.c om 1. Absolute Maximum Ratings Parameter Symbol Min. Ty p . Max. Unit Note S torage T emperature T s -40 85 ºC S torage Ambient Humidity H A 5 95 % Power Supply V oltage V CC -0.
OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 3 Revision: S3 12/20/2007 www .delt aww.c om Note (4). Transmitter spectral limits Note (5). Tr ansmitter eye mask definition 4.
OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 4 Revision: S3 12/20/2007 www .delt aww.c om Note (1). Measure d with Light source +1dBm, 1490 nm, ER=9dB; BER =<10 -12 @PRBS=2 7 -1 NRZ This assuranc e should be m et with asy nchronous dat a flow ing out of the optical transmitter of the system under test.
OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 5 Revision: S3 12/20/2007 www .delt aww.c om 6. T ransmitter Burst Mode Timing Characteristics Parameter Symbol Min. Ty p . Max. Unit No te BiasCNT Enable Duration 1 us Interval of BiasCNT Signal 0.1 12 1000000 us VccT BiasCNT Data Input Optica l Output VccT < 3.
OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 6 Revision: S3 12/20/2007 www .delt aww.c om 8. Pin Description Tx/Rx Pin No. I/O Pin Name Description 1 V eeR Receiver Ground 2 VccR +3.3V Receiver Power Supply 3 O SD Normal Optical Input indicated by logic “High”, and No Optical Input indicated by logic “Low”.
OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 7 Revision: S3 12/20/2007 www .delt aww.c om 9. Recommended Interface Circuit T rans m itter 9. TD ( p) 10. TD(n) 8. Bia sCNT 6. VccT 7. VeeT Receiver 100nF 100nF 2. VccR 5. RD ( p) 4. RD(n) 3. SD 1. VeeR 100nF 10uF 100nF 10uF 100nF 1uH 1uH 3.
OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 8 Revision: S3 12/20/2007 www .delt aww.c om 10. Outline Di mensions Parameter Unit Desc ripti on Note Mechanica l Dimens ions mm 48.
OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 9 Revision: S3 12/20/2007 www .delt aww.c om 1 1. Enhanced Digital Diagnostic Interface The memory map in the follow ing describes an extension to the memory map defined in SFF-8472.
OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 10 Revis ion: S3 12/20/2007 www .delt aww.c om EEPROM Serial ID Memory Content s (2-Wire Address A0h) Addres s Name of Fiel d Hex Desc ripti on Base ID Fields 00 Identifier 80 V endor specific 01 Ext.
OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 11 R e v i s i o n : S 3 12/20/2007 www .delt aww.c om Digit al Diagnostic Monitoring Interface (2-Wire Address A2h) Alarm and W arnin g Thresholds (2 Wire Ad.
OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 12 Revis ion: S3 12/20/2007 www .delt aww.c om A/D V a lue (2 Wire Address A2h) Addres s # Byte s Name of Field Desc ripti on 96-97 2 T emperature ( MSB, LSB).
OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 13 Revis ion: S3 12/20/2007 www .delt aww.c om St atus Bits and Alarm/Warning Flag Bit s (2 Wire Address A2h) Address Bit Name Descri ption 1 10 7 TX Disable S tate No implemented. 1 10 6 Soft TX Disable No implemented.
OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 14 Revis ion: S3 12/20/2007 www .delt aww.c om 12. R egulat ory C ompl iance Feature Te s t M e t h o d Reference Performance Human Body Model (HBM) MIL-STD-883E Method 3015.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.