Operating Instructions & Parts Manual 3VG81 Dayton Pr opane Construction Heater ® Form 5S3928 Please read and save these instructions. Read car efully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information.
Dayton Operating Instructions and Parts Manual 3VG81 2 Dayton Pr opane Construction Heater ® General Safety Information IMPORT ANT : Make certain you r ead and understand all warnings. Keep these instructions for refer ence. They are your guide to safe and proper operation of this heater .
Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 3 Model 3VG81 Carbon monoxide poisoning: Some people are mor e affected by carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea.
Dayton Operating Instructions and Parts Manual 3VG81 4 Dayton Pr opane Construction Heater ® Air For Combustion And Heating Fuel Combustion Chamber DSI Ignitor Clean Heated Air Out (Front) Fan Solenoid V alve Nozzle Motor On/Off Switch Theory of Operation THE FUEL SYSTEM The hose/regulator assembly attaches to the propane gas supply .
Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 5 Model 3VG81 Installation (Continued) Hose Propane T ank Hose POL Fitting Supply V alve Inlet Connector Regulator Vent (pointing down) Figure 4 - Regulator With V ent Pointing Down IMPORT ANT : Extra hose or piping may be used if needed.
Dayton Operating Instructions and Parts Manual 3VG81 6 Dayton Pr opane Construction Heater ® Operation (Continued) Storage Disconnect heater from pr opane supply tank(s). 1. Store propane tank(s) in safe manner . See Chapter 5 of Standard for Storage and Handling of Liquefied Petroleum Gases, ANSI/NFP A 58.
Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 7 Model 3VG81 IGNITOR Make sure gap between ignitor electr ode and burner nozzle is .13 min./.15"max. Access ignitor electrode fr om inside combustion chamber . No other mainte- nance is needed for ignitor .
Dayton Operating Instructions and Parts Manual 3VG81 8 Dayton Pr opane Construction Heater ® Figure 9 - Repair Par ts Illustration For Repair Parts, call 1-800-323-0620 24 hours a day — 365 days a .
Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 9 Model 3VG81 Repair Parts List 1 Upper Shell 098511-116 1 2 * #10-16 x 1/2" Screw M15823-27 8 3 Combustion Cham.
Dayton Operating Instructions and Parts Manual 3VG81 10 Dayton Pr opane Construction Heater ® 41 * #10-32 x 1/4" Screw M12461-25 2 42 * Hex TPG “F” 6-32 s 1/4" Screw M10908-1 2 43 Clip Nut M11271-8 8 44 High T emperature Wire Assembly 101480-10 1 45 High T emperature Wire Assembly 101480-11 1 47 DSI Control No.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Dayton 3VG81 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Dayton 3VG81 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Dayton 3VG81 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Dayton 3VG81 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Dayton 3VG81, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Dayton 3VG81.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Dayton 3VG81. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Dayton 3VG81 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.