Operating Instructions & Parts Manual 3VG79B Dayton Portable For ced Air Heater Description Dayton Model 3VG79B is a 200,000 Btu/Hr heater . This heater uses only Kerosene or No.
Dayton Operating Instructions and Parts Manual 2 Dayton Portable For ced Air Heater ® 3VG79B Figure 2 - Model 3VG79B Product Identification Thermostat Knob General Safety Information Make certain you read and understand all warnings. Keep these instructions for reference.
Dayton Operating Instructions and Parts Manual 3 Model 3VG79B Version B - For Reduction G016.J ® Carbon monoxide poisoning may lead to death! Some people are mor e affected by carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea.
Dayton Operating Instructions and Parts Manual 4 Dayton Portable For ced Air Heater ® 3VG79B Fuels Use only Kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.
Dayton Operating Instructions and Parts Manual 5 Model 3VG79B Version B - For Reduction G016.J ® 4. Place handles on top of fuel tank flange. Insert scr ews through handles, fuel tank flange, and wheel support frame. Attach nut finger tight after inserting each screw .
Dayton Operating Instructions and Parts Manual 6 Dayton Portable For ced Air Heater ® 3VG79B 7. Place setscrew on flat of shaft. Tighten setscrew firmly (40-50 inch-pounds). 8. Replace fan guard and upper shell. AIR OUTPUT , AIR INT AKE, AND LINT FIL TERS 1.
Dayton Operating Instructions and Parts Manual 7 Model 3VG79B Version B - For Reduction G016.J ® Maintenance (Continued) Side Cover Bushing, Lower Fuel Line, and Fuel Filter Figure 10 - Fuel Filter Removal Fuel V alve Fitting 4. Disconnect red and white wir es fr om fuel valve (See Figure 11).
Dayton Operating Instructions and Parts Manual 8 Dayton Portable For ced Air Heater ® 3VG79B Maintenance (Continued) Figure 13 - Ignitor Replacement Combustion Chamber Photocell Bracket Ignitor Ignitor Screw Nozzle Adapter Bracket Nozzle Adapter Bracket Opening Ignitor Element Washer NOZZLE ASSEMBL Y 1.
Dayton Operating Instructions and Parts Manual 9 Model 3VG79B Version B - For Reduction G016.J ® Sandpaper Figure 18 - Sanding Rotor Maintenance (Continued) STORING, TRANSPORTING, OR SHIP- PING NOTE: If shipping, transport companies requir e fuel tanks to be empty .
Dayton Operating Instructions and Parts Manual 10 Dayton Portable For ced Air Heater ® 3VG79B For Replacement Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P .
Dayton Operating Instructions and Parts Manual 11 Model 3VG79B Version B - For Reduction G016.J ® Ref. Part 2E510D 2E511D No. Description Number Qty .
Dayton Operating Instructions and Parts Manual 12 Dayton Portable For ced Air Heater ® 3VG79B Figure 23 - Replacement Parts Illustration Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P .
Dayton Operating Instructions and Parts Manual 13 Model 3VG79B Version B - For Reduction G016.J ® Ref. Part No. Description Number Qty . Ref. Part No.
Dayton Operating Instructions and Parts Manual 14 Dayton Portable For ced Air Heater ® 3VG79B Replacement Parts List for Handle and Wheel Group Ref. Part No.
Dayton Operating Instructions and Parts Manual 15 Model 3VG79B Version B - For Reduction G016.J ® 1. No power to heater 2. Thermostat setting to low 3. Bad electrical connection between motor and ignition control assembly or ignition control assembly and power cor d 4.
Dayton Operating Instructions and Parts Manual 16 Dayton Portable For ced Air Heater ® 3VG79B Manufactured for Dayton Electric Mfg. Co. Niles, Illinois 60714 U.S.A. 107326-01 Rev . D 12/00 Version B - For Reduction G016.J ® NOT A UPC LIMITED WARRANTY DA YTON ONE-YEAR LIMITED WARRANTY .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Dayton 3VG79B è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Dayton 3VG79B - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Dayton 3VG79B imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Dayton 3VG79B ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Dayton 3VG79B, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Dayton 3VG79B.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Dayton 3VG79B. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Dayton 3VG79B insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.