Manuale d’uso / di manutenzione del prodotto 3VG79A del fabbricante Dayton
Vai alla pagina of 16
Operating Instructions & Parts Manual 3VG79A Dayton Portable For ced Air Heater Description Dayton Model 3VG79A is a 200,000 Btu/Hr heater . This heater uses only Kerosene or No.
Dayton Operating Instructions and Parts Manual 2 Dayton Portable Oil-Fir ed Heater ® 3VG79A Lower Shell Hot Air Outlet Fan Guard Fuel T ank Flame-out Control Reset Button Side Cover Fuel Cap Figure 2.
Dayton Operating Instructions and Parts Manual 3 Model 3VG79A Version B - For Reduction G016.J ® General Safety Information Make certain you read and understand all warnings. Keep these instructions for reference. They are your guide to safe and proper operation of this heater .
Dayton Operating Instructions and Parts Manual 4 Dayton Portable Oil-Fir ed Heater ® 3VG79A General Safety Information (Continued) Theory of Operation Fuels Use only Kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.
Dayton Operating Instructions and Parts Manual 5 Model 3VG79A Version B - For Reduction G016.J ® Front Handle Rear Handle Wheel Support Frame Hot Air Outlet Fuel T ank Flange Screw Air Inlet Assembly This model is furnished with wheels and handles. Wheels, handles, and the mounting hardwar e are found in the shipping carton.
Dayton Operating Instructions and Parts Manual 6 Dayton Portable Oil-Fir ed Heater ® 3VG79A FAN IMPORT ANT : Remove fan from motor shaft before r emoving motor from heater . The weight of the motor resting on the fan could damage the fan pitch. 1. Remove upper shell ( See Figur e 6).
Dayton Operating Instructions and Parts Manual 7 Model 3VG79A Version B - For Reduction G016.J ® Figure 10 - Adjusting Pump Pr essure Pressure Gauge Side Cover Bushing, Lower Fuel Line, and Fuel Filter Figure 11 - Fuel Filter Removal Fuel V alve Fitting High V oltage.
Dayton Operating Instructions and Parts Manual 8 Dayton Portable Oil-Fir ed Heater ® 3VG79A Air Line Hose Screw Combustion Chamber Burner Head Spark Plug Wire Spark Plug Fuel Line Hose NOZZLE 1. Remove upper shell (See page 6). 2. Remove fan (See page 6).
Dayton Operating Instructions and Parts Manual 9 Model 3VG79A Version B - For Reduction G016.J ® Sandpaper Gap Adjusting Screw Gap Adjusting Screw .003"/.004" Gap Measured With Feeler Gauge Rotor Blade 5. Remove pump plate. 6. Remove rotor , insert, and blades.
Dayton Operating Instructions and Parts Manual 10 Dayton Portable Oil-Fir ed Heater ® 3VG79A For Replacement Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P .
Dayton Operating Instructions and Parts Manual 11 Model 3VG79A Version B - For Reduction G016.J ® Ref. Part 2E510D 2E511D No. Description Number Qty .
Dayton Operating Instructions and Parts Manual 12 Dayton Portable Oil-Fir ed Heater ® 3VG79A Figure 24 - Replacement Parts Illustration 1 2 3 4 5 6 7 8 23 19 9 10 16 11 12 15 45 25 26 27 24 28 29 20 .
Dayton Operating Instructions and Parts Manual 13 Model 3VG79A Version B - For Reduction G016.J ® 3VG79A Ref. Part No. Description Number Qty . Ref. Part No.
Dayton Operating Instructions and Parts Manual 14 Dayton Portable Oil-Fir ed Heater ® 3VG79A Replacement Parts List for Handle and Wheel Group Ref. Part No.
Dayton Operating Instructions and Parts Manual 15 Model 3VG79A Version B - For Reduction G016.J ® T roubleshooting Chart Possible Cause(s) Corrective Action Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur .
Dayton Operating Instructions and Parts Manual 16 Dayton Portable Oil-Fir ed Heater ® 3VG79A Manufactured for Dayton Electric Mfg. Co. Niles, Illinois 60714 U.S.A. 105559-01 Rev . B 09/99 Version B - For Reduction G016.J ® NOT A UPC LIMITED WARRANTY DA YTON ONE-YEAR LIMITED WARRANTY .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Dayton 3VG79A è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Dayton 3VG79A - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Dayton 3VG79A imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Dayton 3VG79A ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Dayton 3VG79A, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Dayton 3VG79A.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Dayton 3VG79A. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Dayton 3VG79A insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.