Manuale d’uso / di manutenzione del prodotto 1000I del fabbricante Datalogic Scanning
Vai alla pagina of 176
Magellan TM 1000i On-Coun ter Pr esentation Omnidir ectional Bar Code Reader Pr oduc t Refer enc e Guide.
Datalogic Scanning, Inc. 959 T err y Street Eugene, Oregon 974 02 T eleph one: (541) 683-5700 F ax: (541) 345- 7140 An Unpublished W o rk - All rights r eserved.
Product Reference Guide i- i Table of Contents About This Ma nual ............... .......... ........... .......... ............. .......... ........... .......... ........... ........ .. 1-1 Manual Convention s ........... .......... ........... ....
i-ii Magellan ® 1000i Wand Idle State ...... .............. ............. .............. ........... .............. ............. ... 3-27 Signal Speed .................. .............. .............. ............. .............. .............. .....
Product Reference Guide i-iii Start/Stop Character s . ........... ........... .......... ............. .......... ........... .......... ........... .......... . 5-27 Code 39 Full A SCII ........ .......... ........... .......... ........... ........
i-iv Magellan ® 1000i Minimum Reads .................. .......... ........... ............ ........... .......... ........... .......... ........... ... 5-67 2D Symbologie s .................. ........... .......... ........... .......... ...........
Produc t Refe rence Gu ide 1-1 Chapter 1 Getting Star ted The Magellan ® 1000i Omni-D i rectional I maging Scanner offers hands-free scanning for small, easily handled items and handheld scanning for bulkier items. Its aggr essive imaging perfor- mance and intuitive operation reduces user trai ning and speeds checkout for better customer service.
Getting Started 1-2 Magellan ® 1000i C onnecting the S canner The scanner kit you order ed to match your interf ace should provide a comp atible cab le for your installation. U se the appropriate instructions below to connect the scanner to the terminal, PC or other host device.
Programming Product Reference Guide 1-3 Wand Emulation Connection — Connect the scanner to the appropriated port on the ter- minal/PC using the correct cable for the interface type you or dered. Re ference Figure 2 . IBM Connection — Connect the scanner to the IBM port on the terminal/PC using the cor- rect IBM c abl e.
Getting Started 1-4 Magellan ® 1000i LED and Beeper Indicators The scanner ’ s beeper sounds and its green LE D illuminates to indica te various functions or errors on the scanner .
Error Codes Product Reference Guide 1-5 Error C odes U pon startup, if the scanner flashes its indicato r LED or sounds an unexpected series of beep tones (other than normal power-up indications) , this means the scanner has not passed its auto- matic Selftest and has entered FRU 1 isolation mode.
Getting Started 1-6 Magellan ® 1000i NOTES.
Produc t Refe rence Gu ide 2-1 Chapter 2 Gen er al F ea tu re s Double Read T imeout The Double R ead T imeout feature sets a time li mit that determines how much time must pass before reading the same label again (e.g. two identical items in succession).
General Features 2-2 Magellan ® 1000i Double Read Timeout — cont. ST ART / END PROGRAMMING BARCODES 0.7 Second 0.8 Second 0.9 Second 1 Second.
Label Gone Timeout Product Reference Guide 2-3 Label Gone T imeout This feature sets the time after the last label se gment is seen before the scanner prepar es for a new label. Pr oductivit y Index Reporting (PIR) When PIR is enabled, label quality data is appended to decoded data before being presented to the POS.
General Features 2-4 Magellan ® 1000i Sleep Mode This feature specifies t he amount of time with no barcode reads bef ore t he scanner enters sleep mode.
Sleep Mode Product Reference Guide 2-5 Sleep Mode — cont. ST ART / END PROGRAMMING BARCODES 6 Minutes 7 Minutes 8 Minutes 9 Minutes 10 Minutes DEF A UL T 12 Minutes 15 Minutes 30 Minutes 1 Hour.
General Features 2-6 Magellan ® 1000i LED and Beeper Indicators Pow e r O n A l e r t Disables or enables the indication (a single beep ) that the scanner has finished all its power up tests and is now r eady for operation.
LED and Beeper Indicators Product Reference Guide 2-7 Goo d Read: When to In dicate This feature specifies when the scanner will prov ide indication (beep and/or flash its green LED) upon successful ly readin g a barcode.
General Features 2-8 Magellan ® 1000i Good Read Beep C ontr ol This feature enables/disables the scanner’ s ability to beep upon a successf ul decode of a barcode. Good Read Beep F requency Adjusts the good read beep to sound at a selectab le low , medium or high frequency , selectable from the list below .
LED and Beeper Indicators Product Reference Guide 2-9 Good Read Beep Length S pecifies the duration of a good read beep. ST ART / END PROGRAMMING BARCODES 60msec 80msec DEF A UL T 100msec 120msec 140m.
General Features 2-10 Magellan ® 1000i Good Read Beep V olume Selects the bee per volume (loudness) upon a good r ead beep. There ar e three selectable volume levels.
Scanning Features Product Reference Guide 2-11 Scanning F eatures T argeted S canni ng Mode U pon pressing the button, the scanner will project an aiming pattern to assist in centering over the barcode. Scanning then takes place as soon as the button is released.
General Features 2-12 Magellan ® 1000i T arget Mode Linger T ime S pecifies the time duration the scanner remains in the targeted mode of operation after r eading a barcode before reverting to Omni-directional Mode.
Scanning Features Product Reference Guide 2-13 W ake Up Intensity This feature indicates the percentage of ambient light change which will trigger the scanner to wake up from S leep M ode. Lo wer settings pro vide gr eater sensitivity . The seelectable range for this setting is 5% to 15%.
General Features 2-14 Magellan ® 1000i Wake Up Intensity — cont. ST ART / END PROGRAMMING BARCODES 13% 14% 15%.
Produc t Refe rence Gu ide 3-1 Chapter 3 Inter f ace Related F eatures At the time of this writing, the Scanner supports the inter faces listed in Ta b l e 3 - 1 . Select the desired interface type from the table, then re fe rence the page number give n for the customizable features section associated with each interface.
Interface Related Features 3-2 Magellan ® 1000i Table 3-2. Keyboard Wedg e Interface Refer ence I/F T ype PCs Suppor ted A PC/XT w/Alter nate K ey Encoding B A T , PS/2 25-286, 30-286, 50, 50Z, 60, 7.
Interface Selection Product Reference Guide 3-3 Inte r face Selection ST ART / END PROGRAMMING BARCODES RS-232 Standard RS-232 Wincor-Nixdorf IBM 4683 P or t 5B IBM 4683 P or t 9B IBM 4683 P or t 17 U.
Interface Related Features 3-4 Magellan ® 1000i Interface Selection — cont. ST ART / END PROGRAMMING BARCODES K eyboard W edge A K eyboard W edge B K eyboard W edge C K eyboard W edge D K eyboard W.
Interface Selection Product Reference Guide 3-5 Interface Selection — cont. ST ART / END PROGRAMMING BARCODES K eyboard W edge K K eyboard W edge L K eyboard W edge M K eyboard W edge N K eyboard W .
Interface Related Features 3-6 Magellan ® 1000i Interface Selection — cont. ST ART / END PROGRAMMING BARCODES K eyboard W edge T K eyboard W edge U K eyboard W edge V K eyboard W edge W K eyboard W.
Interface Features Product Reference Guide 3-7 Inter f ace F eatures Obey/Ignore Host C ommands When set to ignore host commands, the scanner will ignore all host commands ex cept for the minimum set necessar y to keep the inter face active and transmit labels For normal operation of the interface, select Obey Host Commands.
Interface Related Features 3-8 Magellan ® 1000i Interface Features — cont. Host T ransm ission Buffers S pecifies the number of host transmission(s) that may be buffered. B y buffering data from a bar- code, the scanner can continue to read a new barcode while the old one is being transmitted to the host.
Interface Features Product Reference Guide 3-9 RS-232 Inter face F eatur es ST ART / END PROGRAMMING BARCODES 1200 Baud 2400 Baud 4800 Baud 9600 Baud DEF A UL T 19200 Baud 38400 Baud 57600 Baud 115200.
Interface Related Features 3-10 Magellan ® 1000i RS-232 Interface Features — cont. ST ART / END PROGRAMMING BARCODES 7 Data Bits 8 Data Bits DEF A UL T 1 Stop Bit DEF A UL T 2 Stop Bits Par i t y =.
Interface Features Product Reference Guide 3-11 RS-232 Interface Features — cont. Hardware Flow Control Disable Hardw are Control— The scanner transmits to the host regardless of any activity on the CTS line. Enable CTS Flow Control— The CTS signal controls transmission of data to the host.
Interface Related Features 3-12 Magellan ® 1000i RS-232 Interface Features — cont. Interchara cte r Delay This delay is inserted after each data character tr ansmitted. If the transmission speed is too high, the system may not be able to receive all charac ters.
Interface Features Product Reference Guide 3-13 Intercharacter Delay — cont. So ft ware Flow Control Disables/Enables software cont rol using X ON /X OFF characters .
Interface Related Features 3-14 Magellan ® 1000i RS-232 Interface Features — cont. Host Ec ho When enabled, this feature passes all data throug h the scanner to the host as it comes in. This feature is u sed for applications where “ daisy ch aining” of RS-232 devices onto the same cable is necessary .
Interface Features Product Reference Guide 3-15 RS-232 Interface Features — cont. Host Echo Quiet Interval This setting specifies the time interval of RS-232 channel inactivity which must transpire before the scanner will break the host echo loop to transmit the bar code data that has just been scanned to the host.
Interface Related Features 3-16 Magellan ® 1000i Host Echo Quie t Interval — cont. Signal V oltage: Normal/T TL S pecifies whether the RS-232 interface provides TTL levels on the output pins TxD and R TS.
Interface Features Product Reference Guide 3-17 RS-232 Inv ert Enables/disables inversion of RS-232 TXD and RXD signals. Beep on ASCII BEL Enables/disables ability of scanner to beep (sou nd a good r ead tone) on receiving an ASCII BEL (07 hex).
Interface Related Features 3-18 Magellan ® 1000i Beep on Not on File Select for the host to beep (or not) when a not-on -file (host command) condition is detected by the host.
Interface Features Product Reference Guide 3-19 AC K N A K O p t i o n s This enables/disables the ability of the scan ner to support the RS-2 32 ACK/NAK pr otocol. When configured, the scanner and/or host sends an “ ACK” when it receives data pr operly , and sends “NAK” when the data is in error .
Interface Related Features 3-20 Magellan ® 1000i RS-232 Interface Features — cont. — cont. A CK Character NAK Character ST ART / END PROGRAMMING BARCODES Sets the ACK char acter from the set of ASCII characters or an y decimal v alue from 000 to 255.
Interface Features Product Reference Guide 3-21 RS-232 Interface Features — cont. Retr y on A CK NAK T imeout Enables/disables retry after the configurable ACK NAK T imeout V alue (set in the following fea- ture ) ha s ex pire d.
Interface Related Features 3-22 Magellan ® 1000i RS-232 Interface Features — cont. AC K N A K R e t r y C o u n t ST ART / END PROGRAMMING BARCODES This feature sets the number of times f or the scanner to retry a label transmi ssion under a retr y condition.
Interface Features Product Reference Guide 3-23 RS-232 Interface Features — cont. A CK NAK Error Handling This item specifies the method the scanner will use to handle errors detect ed while waiting to receive the ACK character from the host. Errors include unrecognized host commands and com - munication errors such as parity or framing err ors.
Interface Related Features 3-24 Magellan ® 1000i RS-232 Interface Features — cont. T ransmission F ailure Indication Enables/disables bad-label indication upon transmission failure. USB- OEM Inter face F eatures USB- OEM Device usage The USB-OEM protocol allows for the scanner to be identified as one of two different types of barcode scanners.
Interface Features Product Reference Guide 3-25 IBM IBM T ransm it Labels in Code 39 F ormat This feature enables/disables scanner's ability to set a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host.
Interface Related Features 3-26 Magellan ® 1000i Wa n d E m u l a t i o n Suppor ted Symbologies The W and Emulation interface will transmit barcod e data as a wand device woul d.
Interface Features Product Reference Guide 3-27 Wand Emulation — cont. Bar/Space P olari ty Low/H igh — Black will be transmitted as a low vo ltage level (0 to +0.7V) and space as high level (+2.4 to +5 .25V). High/Lo w — Black will be transmitted as a high v oltage level (+2.
Interface Related Features 3-28 Magellan ® 1000i Wand Emulation — cont. Signal Speed The speed of the transmission can be set. This selects the width of the minimum narrow bar . 330 microseconds 660 microseconds T ransmit T railing Noise The transmission of noise pulses after the label may be enabled or disabled.
Interface Features Product Reference Guide 3-29 Wand Emulation — cont. T ransmit L eading Noise The transmission of noise pulses befor e the barcode may be enabled or disabled. Symbology C onv ersion W and Emulation can convert all barcodes to a single symbology .
Interface Related Features 3-30 Magellan ® 1000i Key b o a rd W ed g e and USB Ke yboard As a keyboard interface, th e sc anner supports most popular PCs and IBM term inals. The instal- lation of the wedge is a fairly simple pr ocess that doesn ’ t requir e any changes of software or hard- ware.
Interface Features Product Reference Guide 3-31 Keyboard Wedge — c ont. ST ART / END PROGRAMMING BARCODES Italy Norwa y P or tugal Spain Sweden Switzerland Japan 106 K ey Hungar y Czech.
Interface Related Features 3-32 Magellan ® 1000i Keyboard Wedge — c ont. Caps Loc k S tat e S pecifies the format in which th e scanner sends character data.
Interface Features Product Reference Guide 3-33 Keyboard Wedge — c ont. P ower-On Simulation All PCs check the keyboard status during the po wer-on S elftest. I t is recommended that y ou enable this function if you are working without a keyboard installation.
Interface Related Features 3-34 Magellan ® 1000i Con tr o l C ha r ac t er s S pecifies how the scanner transmits ASCII co ntrol characters to the host. Choices are: • Disable Contr ol Characters • Enable transmission of control characters to host • Send characters betw een 00H and 1FH acco rding to a special function-key mapping table.
Interface Features Product Reference Guide 3-35 Keyboard Wedge — c ont. W edge Quie t Interval Quiet Interval is the amount of time to look fo r keyboard activity be fore the scanner breaks the keyboard connection in or der to transmit data to the host.
Interface Related Features 3-36 Magellan ® 1000i Keyboard Wedge — c ont. Intercharac ter De lay USB C OM Inter face Set-up This interface uses the Microsoft Windows USB COM driver . Before plugging your reader into the host PC, please ensure you have alr ead y copied the DLS_EUG_CDC_ACM.
Produc t Refe rence Gu ide 4-1 Chapter 4 Data Editing Data Editing Ov er view When a barcode is scanned, additional informatio n can be sent to the host computer along with the barcode data. This combination of barcode data and supplementary user-defined data is called a “ message string.
Data Editing 4-2 Magellan ® 1000i Global Pr efix/Suffix U p to 20 ASCII characters may be added as a prefix (in a position before the barcode data) and/ or as a suffix (in a position following the barcode data) as indicated in Figure 4-2 . Figure 4-2.
Global Prefix/Suffix Product Reference Guide 4-3 Global Prefix/Suffix — cont. ST ART / END PROGRAMMING BARCODES Sets up to 20 characters each from the set of ASCII characters or an y hex v alue from 0 to FF .
Data Editing 4-4 Magellan ® 1000i AIM ID AIM (Automatic I dentification Manufacturers) la bel identifiers ar e assi gned from a globally standardized list — as opposed to custom label ID characters you select y ourself — and can be included with scanned barcode data.
Label ID Product Reference Guide 4-5 Label ID A Label ID is a customizable code of up to two ASCII c haracters (00-FF), used to identify a bar- code (symbology) type.
Data Editing 4-6 Magellan ® 1000i Label ID — cont. ST ART / END PROGRAMMING BARCODES Label ID T ransmission: Disable Label ID P osition: Before Bar code Data DEF A UL T Label ID P osition: After Ba.
Label ID Product Reference Guide 4-7 Label ID — cont. ST ART / END PROGRAMMING BARCODES DEF A UL T SETTING FOR THIS FEA TURE: E (45 hex) Set UPC-E w/P2 Addon Label ID Character(s) Set UPC-E w/P5 Add.
Data Editing 4-8 Magellan ® 1000i Label ID — cont. ST ART / END PROGRAMMING BARCODES DEF A UL T SETTING FOR THIS FEA TURE: F (46 hex) Set EAN-13 w/P2 Addon Label ID Character(s) Set EAN-13 w/P5 Add.
Label ID Product Reference Guide 4-9 Label ID — cont. ST ART / END PROGRAMMING BARCODES DEF A UL T SETTING FOR THIS FEA TURE: G8 (4738 hex) Set GTIN w/C128 addon Label ID Character(s) Set GS1 Omnidi.
Data Editing 4-10 Magellan ® 1000i.
Label ID Product Reference Guide 4-11 Label ID — cont. ST ART / END PROGRAMMING BARCODES DEF A UL T SETTING FOR THIS FEA TURE: % (25 hex) Set Codabar Label ID Character(s) Set Code 93 Label ID Chara.
Data Editing 4-12 Magellan ® 1000i Case C onv ersion This feature can convert scanned barcode data to ei ther all lo wer case (a through z) or all upper case (A through Z) characters . NO TE Case con version affects ONL Y scanned barcode data, and does not affect Label ID , Prefix, Suffix, or other appended data.
Character Conversion Product Reference Guide 4-13 Character C on version Character conversion is an eight byte configurati on item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted.
Data Editing 4-14 Magellan ® 1000i.
Produc t Refe rence Gu ide 5-1 Chapter 5 Sy m b o l o g i e s The scanner supports the following symbologies (barcode types). Option s for each symbology are included in this chapter . Factory Defaults— for the standard RS-232 interface are indicated in bold text throughout this section.
Symbologies 5-2 Magellan ® 1000i UPC-A — continued Check Digit T ransmission Enable this option to transmit the check digit along with UPC-A barcode data. Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the sym- bology ID to match those required for EAN-13.
UPC-A Product Reference Guide 5-3 UPC-A — continued Number Sy stem T ransmission This feature enables/disables transmission of UPC-A System N umber . UPC-A Minimum R eads This feature specifies the minimum number of consecutive times a UPC-A label must be decoded before it is accepted as good r ead.
Symbologies 5-4 Magellan ® 1000i UPC-A — continued UPC-A In-stor e Minimum Reads This feature specifies the minimum number of co nsecutive times an in-store printed label must be decoded before it is accepted as good read.
UPC-E Product Reference Guide 5-5 UPC-E The following options apply to the UPC-E symbology . Disable/Enable UPC-E When disabled, the scanner will not read UPC-E barcodes. Check Digit T ransmission Enable this option to transmit the check digit along with UPC-E barcode data.
Symbologies 5-6 Magellan ® 1000i UPC-E — continued Number Sy stem Digit The N u mber System D igit (NSD) which is always a zero (0) in the leading position can be optionally included (or not) with scanned barcode data. Expand to UPC-E to UPC-A Enables/disab les expansion of UPC-E l abels to UPC-A.
UPC-E Product Reference Guide 5-7 UPC-E — continued Expand UPC-E to EAN13 Enables/disables expansion of UPC-E labels to EAN-13. Selecting this featur e also changes the symbology ID to match those required for EAN-13.
Symbologies 5-8 Magellan ® 1000i GTIN The following options apply to the GTIN label data format. Expand UPC/EAN to GTIN When this feature is enabled, the scanner will transl ate UPC/EAN labels to the 14 digit GTIN format.
EAN-13 Product Reference Guide 5-9 EAN-13 The following options apply to the EAN-13 symbology . Disable/Enable EAN-13 When disabled, the scanner will not read EAN-13 barcodes. Check Digit T ransmission Enable this option to transmit the check digit along with EAN-13 barcode data.
Symbologies 5-10 Magellan ® 1000i EAN-13 — continued EAN-13 Flag 1 C haracter Enables/disables transmission of an EAN/JAN13 Flag1 character . ISBN When enabled, this feature truncates the leading three digits from labels that contain ISBN (International S tandard Book Number) and append s an ISBN check character to the end of the label.
EAN-13 Product Reference Guide 5-11 EAN-13 — continued Minimum Reads This feature specifies the minimum number of consecutive times an EAN-13 label must be decoded before it is accepted as good r ead.
Symbologies 5-12 Magellan ® 1000i EAN-8 The following options apply to the EAN-8 symbology . Disable/Enable EAN-8 When disabled, the scanner will not read EAN-8 barcodes. Check Digit T ransmission Enable this option to transmit the check Digit along with EAN-8 barcode data.
EAN-8 Product Reference Guide 5-13 EAN-8 — continued Expand EAN-8 to EAN-13— Expands EAN-8 data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.
Symbologies 5-14 Magellan ® 1000i Enable EAN T wo-Label Enables/disables the ability of the scanner to decode EAN two-label pairs. ST ART / END PROGRAMMING BARCODES Disable EAN T wo-Label Enable EAN .
Add-ons Product Reference Guide 5-15 Add-ons Add-ons (or supplemental characters) are commonly added to the end of UPC/EAN barcodes. The scanner will read the add-ons if they are en abled and in the field of view . Three add-on types are supported: 2-digit, 5-digit and Code 128 add-ons.
Symbologies 5-16 Magellan ® 1000i Add-ons — continued ST ART / END PROGRAMMING BARCODES Disable Optional 2-Digit Add-ons DEF A UL T Enable Optional 2-Digit Add-ons Disable Optional 5-Digit Add-ons .
GS1 DataBar Omnidirectional / Stacked Omni directional Product Reference Guide 5-17 GS1 DataBar Omnidirec tional / Stacked Omnidir ec tional The following options apply to the GS1 D ataBar O mnidirectional symbology .
Symbologies 5-18 Magellan ® 1000i GS1 DataBar Omnidirectional / Stacked Omnidirectional — continued Minimum Reads This feature specifies the minimum number of consecutive times an GS1 DataBar Omnidirec- tional label must be decoded before it is accepted as good read.
GS1 DataBar Expanded / Expanded Stacked Product Reference Guide 5-19 GS1 DataBar Expanded / Expanded Stacked The following options apply to the GS1 D ataBar E xpanded symbology . Disable/Enable GS1 DataBar Expanded When this feature is disabled, the scann er will not read GS1 DataBa r Expanded barcodes.
Symbologies 5-20 Magellan ® 1000i GS1 DataBar Expanded / Expa nded Stacked — continued Len gth Contro l Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths.
GS1 DataBar Expanded / Expanded Stacked Product Reference Guide 5-21 GS1 DataBar Expanded / Expa nded Stacked — continued GS1 DataBar Expanded L ength 1, L ength 2 Progr amming I nstructions 1. Scan the ST AR T/END barcode. 2. Scan either the Set Length 1 or Set Length 2 bar code.
Symbologies 5-22 Magellan ® 1000i GS1 DataBar Expanded / Expa nded Stacked — continued Minimum Reads This feature specifies the minimum number of consecutive times an GS1 DataBar Expanded label must be decoded before it is accepted as good r ead.
GS1 DataBar Expanded / Expanded Stacked Product Reference Guide 5-23 GS1 DataBar Expanded / Expa nded Stacked — continued Co up o n Re a d Co nt r ol This feature controls coupon reading.
Symbologies 5-24 Magellan ® 1000i GS1 DataBar Limited The following options apply to the GS1 DataB ar Limited symbology . Disable/Enable GS1 DataBar Limited When this feature is disabled, the scanner will not read GS1 DataBar Limited barcodes.
GS1 DataBar Limited Product Reference Guide 5-25 GS1 DataBar Limited — continued Minimum Reads This feature specifies the minimum number of consecutive times an GS1 DataB ar Limited label must be decoded before it is accepted as good r ead.
Symbologies 5-26 Magellan ® 1000i Co d e 3 9 The following options apply to the Code 39 symbology . Disable/Enable C ode 39 When this feature is disabled, th e scanner will not read Code 39 barcodes. Check Character Calcula tion When enabled, the scanner will calculate the check character of the labels.
Code 39 Product Reference Guide 5-27 Check Character T ransmit Enable this option to transmit the check character with scan ned barcode data. Start/Stop Characters Enables/disables transmission of Code39 start and stop characters.
Symbologies 5-28 Magellan ® 1000i Code 39 F ull ASCII Enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters . ST ART / END PROGRAMMING BARCODES Disable Code 39 Full .
Code 39 Product Reference Guide 5-29 Code 39 — continued Len gth Contro l Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths.
Symbologies 5-30 Magellan ® 1000i Code 39 L ength 1, Length 2 Progr amming Instruc tions 1. Scan the ST AR T/END barcode. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. T urn to Append ix C , Alpha-Numer ic P ad and scan the three digits (zero padded) r epresent- ing the length in decimal notation.
Code 39 Product Reference Guide 5-31 Code 39 — continued C ode 39 Stitching Enables/disables stitching for Code 39 labels. Wh en parts of a Code 39 barcode are presented to the scanner with this fea.
Symbologies 5-32 Magellan ® 1000i Pharmacode 39 The following options apply to the Pharmacode 39 symbology . Disable/Enable Pharmac ode 39 When this feature is disabled, the scann er will not read Pharmacode 39 barcodes. Start/Stop Characters Enables or disables transmission of Pharmacode 39 start/stop characters.
Pharmacode 39 Product Reference Guide 5-33 Check Character T ransmit Enable this option to transmit the check character with scan ned barcode data. ST ART / END PROGRAMMING BARCODES Disable Chec k Cha.
Symbologies 5-34 Magellan ® 1000i C ode 128 The following options apply to the Code 128 symbology . Disable/Enable C ode 128 When this feature is disabled , the scanner will not read Code 128 barcode s. Disable/Enable EAN 128 When this feature is disabled, th e scanner will not read EAN 128 barcodes.
Code 128 Product Reference Guide 5-35 Code 128 — continued T ransmit F unction Characters Enables/disables transmission of Code128 function characters 1, 2, 3, and 4.
Symbologies 5-36 Magellan ® 1000i Code 128 — continued Len gth Contro l Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths.
Code 128 Product Reference Guide 5-37 Code 128 — continued C ode 128 Length 1, Length 2 P rogr amming Instruct ions 1. Scan the ST AR T barcode. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. T urn to Append ix C , Alpha-Numer ic P ad and scan the three digits (zero padded) r epresent- ing the length in decimal notation.
Symbologies 5-38 Magellan ® 1000i Code 128 — continued Code 128 Stitching Enables/disables stitching for C ode 128 labels. When par ts of a Code 128 barcode are presented to the scanner with this f.
Interleaved 2 of 5 Product Reference Guide 5-39 Inte rleav ed 2 of 5 The following options apply to the I nterleaved 2 of 5 (I 2 of 5) symbo logy . Disable/Enable Interlea v ed 2 of 5 When this feature is disabled, the scann er will not read Interleaved 2 of 5 barcodes.
Symbologies 5-40 Magellan ® 1000i Interleaved 2 of 5 — continued Check Digit T ransmit Enable this option to transmit the check digit with scanned barcode data.
Interleaved 2 of 5 Product Reference Guide 5-41 Interleaved 2 of 5 — continued Len gth Contro l Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths.
Symbologies 5-42 Magellan ® 1000i Interleaved 2 of 5 — continued Interleav ed 2 of 5 Le ngth 1, Length 2 Pr ogramming Instructions 1. Scan the ST AR T barcode.
Interleaved 2 of 5 Product Reference Guide 5-43 Interleaved 2 of 5 — continued Interleav ed 2 of 5 Stitching Enables/disables stitching for Interleaved 2 of 5 labels.
Symbologies 5-44 Magellan ® 1000i Interleaved 2 of 5 — continued Minimum Reads This feature specifies the minimum number of consecutive times an Interleaved 2 of 5 lab el must be decoded before it is accepted as good r ead.
Codabar Product Reference Guide 5-45 Co d a b a r The following options apply to the Codabar symbology . Disable/Enable C odabar When this feature is disabled, the scann er will not read Codabar barcodes. Check Character V erification When enabled, the scanner wil l verify the check character of the labels .
Symbologies 5-46 Magellan ® 1000i Check Character T ransmit Enable this option to transmit the check character with scan ned barcode data. ST ART / END PROGRAMMING BARCODES Disable Chec k Char T rans.
Codabar Product Reference Guide 5-47 Codabar — continued Len gth Contro l Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths.
Symbologies 5-48 Magellan ® 1000i Codabar — continued C odabar Length 1, L ength 2 Progr amming I nstructions 1. Scan the ST AR T barcode. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. T urn to Append ix C , Alpha-Numer ic P ad and scan the three digits (zero padded) r epresent- ing the length in decimal notation.
Codabar Product Reference Guide 5-49 Codabar — continued Start/Stop Character T ype Codabar has four pairs of S tart/Stop patterns. Select one pair to match y our application. Start/Stop Charac ter T ransmission The transmission of start and end char acters of Codabar is selected below .
Symbologies 5-50 Magellan ® 1000i Start/Stop Character Match This feature enables/disables the requirem ent that start and stop characters match . Codabar Stitching Enables/disables stitching for Codabar labels.
Codabar Product Reference Guide 5-51 Codabar — continued Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as a good read.
Symbologies 5-52 Magellan ® 1000i Co d e 9 3 The following options apply to the Code 93 symbology . Disable/Enable C ode 93 When this feature is disabled, th e scanner will not read Code 93 barcodes.
Code 93 Product Reference Guide 5-53 Code 93 — continued Len gth Contro l Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths.
Symbologies 5-54 Magellan ® 1000i Code 93 — continued Code 93 L ength 1, Length 2 Progr amming Instruc tions 1. Scan the ST AR T barcode. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. T urn to Append ix C , Alpha-Numer ic P ad and scan the three digits (zero padded) r epresent- ing the length in decimal notation.
Code 93 Product Reference Guide 5-55 Code 93 — continued C ode 93 Stitching Enables/disables stitching for Code 93 barcodes. When par ts of a Code 93 label are presented to the scanner with this fea.
Symbologies 5-56 Magellan ® 1000i MSI/Plessey The following options apply to the MSI/Plessey symbology . Disable/Enable MSI/Plessey When this feature is disabled, th e scan ner will not read MSI/Plessey barcodes. Check Digit V erification This feature specifies whether one or two check digits are to be calculat ed and verified.
MSI/Plessey Product Reference Guide 5-57 MSI/Plessey — continued Check Digit T ransmit When this option is enabled, the scanner will transmit one-digit or two-digit check digits, depending upon the setting for check digit verification.
Symbologies 5-58 Magellan ® 1000i MSI/Plessey — continued Len gth Contro l Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths.
MSI/Plessey Product Reference Guide 5-59 MSI/Plessey — continued MS I/ Ple ss ey Len gth 1 , Len gt h 2 Progr amming Instruc tions 1. Scan the ST AR T barcode.
Symbologies 5-60 Magellan ® 1000i MSI/Plessey — continued MSI/Plessey S titching Enables/disables stitching for MSI/Plessey barc odes. When parts of an MSI/Ple ssey label ar e presented to the scan.
MSI/Plessey Product Reference Guide 5-61 MSI/Plessey — continued Minimum Reads This feature specifies the minimum number of consecutive times an MSI/Ples sey label must be decoded before it is accepted as good r ead.
Symbologies 5-62 Magellan ® 1000i Standar d 2 of 5 The following options apply to the S tandard 2 of 5 symbology . Disable/Enable Standard 2 of 5 When this feature is disabled, th e scanne r will not read S tandard 2 of 5 barcodes. Check Digit V erification When enabled, the scanner wil l verify the check digit of the label s.
Standard 2 of 5 Product Reference Guide 5-63 Standard 2 of 5 — continued Check Digit T ransmit When this option is enabled, the scanner will transmit the check digit.
Symbologies 5-64 Magellan ® 1000i Standard 2 of 5 — continued Len gth Contro l Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths.
Standard 2 of 5 Product Reference Guide 5-65 Standard 2 of 5 — continued Standard 2 of 5 L ength 1, Length 2 P rogr amming Instruc tions 1. Scan the ST AR T barcode.
Symbologies 5-66 Magellan ® 1000i Standard 2 of 5 — continued Stand ard 2 of 5 Stitchi ng Enables/disables stitching for Standar d 2 of 5 ba rcodes.
Standard 2 of 5 Product Reference Guide 5-67 Standard 2 of 5 — continued Minimum Reads This feature specifies the minimum number of c onsecutive times a Standard 2 of 5 label must be decoded before it is accepted as good r ead.
Symbologies 5-68 Magellan ® 1000i.
Produc t Refe rence Gu ide 6-1 2D S ymbologies & Advanc ed Decoding Fe a t u r e s NO TE The features in this section are a vailab le ONL Y for models with 2D features activated.
2D Symbologies & Advanced Decoding Features 6-2 Magellan ® 1000i 2D Symbologies The scanner supports the following 2D symbologies (barcode types): PDF 417 and Datamatrix . Options for each symbology are included in this addendum. Factory Defaults— for the std.
2D Symbologies Product Reference Guide 6-3 PDF 417 — continued Leng th Cont rol Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths.
2D Symbologies & Advanced Decoding Features 6-4 Magellan ® 1000i PDF 417 — continued PDF 417 Length 1, Length 2 Pr ogramming Instructions 1. Scan the ST AR T barcode. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. T urn to Alpha-Numer ic P ad and scan the four hex digits repr esenting the length in hexi dec- imal notation.
2D Symbologies Product Reference Guide 6-5 PDF 417 — continued Minimum Reads This feature specifies the minimum number of consecutive times a PDF 417 label must be decoded before it is accepted as good r ead.
2D Symbologies & Advanced Decoding Features 6-6 Magellan ® 1000i Datamatrix Disable/Enable Datamatrix When disabled, the scanner will not read Datamatrix barcodes.
2D Symbologies Product Reference Guide 6-7 Datamatrix — continued Leng th Cont rol Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths.
2D Symbologies & Advanced Decoding Features 6-8 Magellan ® 1000i Datamatrix — continued Datamatrix L ength 1, Length 2 Pr ogramming Instr uctions 1.
2D Symbologies Product Reference Guide 6-9 Datamatrix — continued Minimum Reads This feature specifies the minimum number of consecutive times a Datamatrix label must be decoded before it is accepted as good r ead.
2D Symbologies & Advanced Decoding Features 6-10 Magellan ® 1000i Image Capture How t o Capture an Image T o initiate an Image Captur e, scan the IMAG E CAPTURE label below , and press the button. A targeting “ pointer ” will be illuminated while the button is pressed.
Produc t Refere nce Guid e A-1 Chapter A Pr oduc t Specifications Optical and Read P er formanc e P aramet ers Scanner Dimensions Pa rameter Specification Scan V olume 70 cubic inches Scan P attern 10.
A-2 Magellan ® 1000i Ph ysical Pr oper ties Electrical Par ameters Environ ment al Param eter s Other Para meters Pa rameter Specification Dimensions (Scanner onl y): 3.3” x2.8” x3.7” Dimensions (Scanner w/Base Station): 5.5” x2.9” x3.8” We ight (Scanner) 7.
Produc t Refere nce Guid e B-1 Chapter B Ca b l e Pi n ou t s Stan dard Cab le Pi nouts (P rimar y Inter face Cables) RS-232 IBM P or t 5B/9B/17 1 2C T S 3 4R T S 5R X D 6T X D 7 8 VCC IN 9G N D 10 1 .
Cable Pinouts B-2 Magellan ® 1000i USB- OEM USB, USB K eyboard & USB C OM Wa n d E m u l a t i o n Key b o a rd W ed g e 1 2 3 4D - 5 6D + 7 8V I N 9G N D 10 1 2 3 4D - 5 6D + 7 8 VBUS_VIN 9G N D.
Produc t Refere nce Guid e C-1 Chapter C Alpha-Numeric Pad A B C D E F.
C-2 Magellan ® 1000i Alpha-Numeric Pad 1 2 3 0 9 8 7 6 5 4.
Produc t Refere nce Guid e D-1 Appendix D Default Settings Defaults by S ymbology The following is a partial list of key settings for each symbology type.
D-2 Magellan ® 1000i Inte r face Default Ex ceptions The factory defaul t settings indicated in the programming sections (in bold text) reflect factory configuration for the RS-232 standard interface. The follo wing tables list de fault exceptions by interface for the remaining available interfaces.
Interface Default Exceptions Product Referenc e Guide D-3 Interface Default Exceptions — continued RS-232 Winc or/Nix dor f Parameter Default Setting Interf ace T ype RS-232-WN Number of Host T rans.
D-4 Magellan ® 1000i Interface Default Exceptions — continued Wa n d E m u l a t i o n Key b o a rd s Keyboard interfaces include USB Keyboard and Keyboard W edge A-Y.
Produc t Refere nce Guid e E-1 Appendix E K eyboard F unc tion K ey Mappings K eyboard Model Cr oss Refer ence Ta b l e E - 1 summarizes the keyboard models, their defined protoc ol, scancode set, and some unique featu res. The remaining tables in this chapter pro vide the function key maps associated with each of the scanc ode sets.
E-2 Magellan ® 1000i Table E-2. Scanset 1 Function K ey Map Table E-3. Scanset 2 Function K ey Map ASCII (hex) ASCII code K ey Scancode 00 NUL AL T right Make E0h 38h 01 SOH AL T right Break E0h B8h .
Keyboard Model Cross Reference Product Referenc e Guide E-3 Table E-4 . Scanset 3, 102-Key Fu nction Key Map 1B ESC ESC 76h 1C FS F7 83h 1D GS F8 0Ah 1E RS F9 01h 1F US F10 09h ASCII (hex) ASCII code .
E-4 Magellan ® 1000i Table E-5. Scanset 3 122-Key Funct ion Key Map ASCII (hex) ASCII code Key Scancode 00 NUL AL T Right Make 39h 01 SOH AL T Right Break F0h 39h 02 STX AL T left Make 19h 03 ETX AL .
Keyboard Model Cross Reference Product Referenc e Guide E-5 Table E-6. Japanese DOS Function Key Map ASCII value ASCII code Key Scancode 00h NUL AL T right Make 31h 01h SOH AL T r ight Break B1h 02h S.
E-6 Magellan ® 1000i Table E-7. NEC 98 01-Key Function K ey Map ASCII value ASCII code Ke y Scancode 00h NUL unused n/a 01h SOH CR 1Ch 02h STX CAPS LOCK ON (make) 71h 03h ETX CAPS LOCK OFF (break) F1.
Produc t Refere nce Guid e F-1 Chapter F Host C ommands Ac cepting RS-232 Commands The scanner responds to the following RS-232 commands: If one of the abo ve commands is received, the scanner wi ll perform the steps indicated for the command. Host commands for other interfaces are also availa ble.
F-2 Magellan ® 1000i NO TES.
Produc t Refere nce Guid e G-1 Chapter G Sam ple S ym bo ls 0 1234567890 1234567890 Code 128 9 780330 290951 BC321 123456-9$ 123456 UPC-A Code 128 Code 39 Code 93 Interleav ed 2 of 5 EAN-13 Code 2 of .
G-2 Magellan ® 1000i Sample Symbols (01)00123456789012 GS1 DataBar Omni- 0100123456789050 GS1 DataBar Expanded.
ASCII Char t ASCII Char . Hex No . ASCII Char . Hex No. AS CII Char . Hex No. AS CII Char . He x No . NUL SOH STX ETX EO T ENQ AC K BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM S.
Au st ra li a Datalogic Scanning Pt y Ltd T elephone: [61] (2) 9870 3200 australia.scanning@datalogic.com Fra n c e a n d B e n e l u x Datalogic Scanning Sarl T elephone: [33].01.64.86.71.00 france.scanning@datalogic .com German y Datalogic Scanning GmbH T elephone: 49 (0) 61 51/93 58-0 germany .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Datalogic Scanning 1000I è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Datalogic Scanning 1000I - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Datalogic Scanning 1000I imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Datalogic Scanning 1000I ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Datalogic Scanning 1000I, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Datalogic Scanning 1000I.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Datalogic Scanning 1000I. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Datalogic Scanning 1000I insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.