MODEL 833 “FUEL ” GAGE/HOUR METER W/“PUSH- Read Instructions Carefully ! ® !.
Saf ety Instructions This instrument was manuf actured and tested according to the applicable technical standards . It complies with all the safety regulations as shipped from the f actory . Installation and star tup must be performed by skilled personnel.
! T ABLE OF CONTENTS P age 1. Model Encodement 2 2. T echnical Specifications 2.1 Electrical 4 2.2 Mechanical 5 2.3 Environmental 6 3. Installation 7 4.
2 1. MODEL ENCODEMENT 833RB vvvv w V oltage 0024 Reset lev el B = 2.09 VPC.
3 xy zzzz ! Discharge profile C = Adjustable (See T able 3.) Output J = N.C. holding rela y Contact rating = 3 Amps when continuously closed, 1 Amp when opening 316O O = Cur tis logo.
4 2. TECHNICAL SPECIFICA TIONS 2.1 Electrical Operating Range ± 25% of nominal voltage Operating Current V oltage (volts) Nominal Current (mA) Maximum Current (mA) 24 18 28 Rela y Contact Ratings V o.
2.2 Mechanical Displa y Battery state-of-charge: 10-bar , tr i-color LED Hour Meter: 6-digit LCD , 5mm high Resolution Hour Meter 99,999.9 Hours Hardware Kit Mounting brack et, thumbnuts or M4 He x nuts (2), lock w ashers (2), mating connector Molex No .
6 2.3 En vironmental T emperature Operating: - 4 0 ° C t o + 65 ° C (Standard Mode) -10° C to +65° C (Push-to-read Mode) Storage: - 5 0 ° C t o + 9 0 ° C Humidity 95% RH (Non Condensing) at 38°C Shock & Vibration 2.
7 ! 3. INST ALLA TION The Model 833 Installation Kit includes a pre-assembled mating connector with 5” ter minated wires. Ask for Curtis Part Number 15369002.
8 ! Pin 5 = Battery – Connect to battery ground as close to batter y as possible . Pin 2 = Keys witch The ke yswitch turns on and off the LED displa y of the battery discharge indicator. Monitoring of the batter y continues when Pin 2 is turned off and the display is not lit.
9 Pin 3 = Relay (+) Pin 3 connects in series with the lift coil circuit (or the circuit to be switched at empty). For holding rela y (J), Pin 3 must be electrically closer to batter y + than Pin 4 Pin 4 = Relay (–) Pin 4 also connects in series with the circuit to be s witched at empty .
Ta b le 1. Hour Meter Contr ol Lines & Impedance Specifications Model Lo w V olt a ge High V oltage Min. Impedance Maximum Minim um HRM+ HRM- 24 VDC 5.
! 11 NO TE : Fuses and Wires Regulations may require that the Model 833 be fused. If installing a fuse, use a 10A fuse wired with 1.5mm or equivalent wire . The voltage drop across the fuse , its holder , and connectors must be less than 1% of the nominal system voltage .
12 CUR TIS Model 833 Rear Vie w !.
13 Connections f or T ypical Model 833 Application V ehicle system voltage is the higher of the two oper ating vo ltages of a dual voltage unit. Hour meter measures “ke yswitch on” time.
14 4. OPERA TION Displa y The Cur tis Model 833 combines in one instrument a completely solid state LED battery state-of-charge indicator , an LCD hour meter , and lift lockout. Only when battery is proper ly charged is right most LED (1) lit. As battery’s state-of-charge decreases , successive LEDs light up , one at a time.
15 Push-to-read When the front button is depressed, the LCD will displa y the hour meter reading for 6 seconds min. The hour meter will not accumulate time during this operation.
16 5. T r oubleshooting The follo wing checklist should help y ou to troubleshoot an y problems with the instrument. Problem P ossible Causes No display T er minals not connected or improper voltage S.
17 6. Maintenance Model 833 Series is not ser viceable in the field. Units returned to the factory within the warranty period (see inside backco ver) will be replaced without charge.
Guarantee - Cur tis Instruments’ products and/or components are guaranteed against def ects in workmanship and material f or a period of two y ears, or as defined in the individual product literature, from date of shipment from our f actory , when applied in a proper application within specified ratings.
CURTIS INSTRUMENTS, INC. 200 Kisco A venue, Mt. Kisco, NY 10549 T el. (914) 666-2971 • FAX (914) 666-2188 53024 REV A 7/01.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Curtis Computer 833 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Curtis Computer 833 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Curtis Computer 833 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Curtis Computer 833 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Curtis Computer 833, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Curtis Computer 833.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Curtis Computer 833. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Curtis Computer 833 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.