Crestron MMK-6X-DSW & WMKM-6X-DSW Mud Mount Kits for the TPS-6X-DSW Installation Guide.
Crestron MMK/WMKM-6X-DSW Mud Mount Kits for the TPS-6X-DSW Contents Mud Mount Kits for the TPS-6X-D SW: MMK-6X-DSW & WMKM-6X-DSW 1 Description ........................................................................................................
Crestron MMK/WMKM-6X-DSW Mud Mount Kits for the TPS-6X-DSW Mud Mount Kits for the TPS-6X-DSW: MMK-6X-DSW & WMKM-6X-DSW Description Mud Mount Kits are the preferre d mounti ng optio n for the TPS-6X-DSW when the cutout made in the drywall for docking station installation is too large.
Mud Mount Kits for the TPS-6X-DSW Crestron MMK/WMKM-6X-DSW Setup Supplied Hardware The MMK-6X-DSW consists of three parts. These parts produce an asse mbly that attaches to the BB-6X-DSW or PMK-6X-DSW.
Crestron MMK/WMKM-6X-DSW Mud Mount Kits for the TPS-6X-DSW Dimensional Drawing – Adjustment Plate 0. 38 in (0 .95 c m ) 0. 38 i n ( 0. 95 c m ) 10 . 24 i n ( 26. 01 c m ) Dimensional Drawing – Mounting Plate 10 .31 in (26 . 19 c m ) 8. 0 0 i n (2 0.
Mud Mount Kits for the TPS-6X-DSW Crestron MMK/WMKM-6X-DSW Drywall Cutout Template and Dimensio ns (supplied with WMKM-6X-DSW only) 7 11 / 16 i n (196 mm ) 9 1/ 16 i n (230 mm ) 6 9/ 16 i n (167 mm ) 6 1/ 8 i n (156 mm ) Installation This section pr ovides an i nstallation proce dure for eac h Mud Mou nt Kit.
Crestron MMK/WMKM-6X-DSW Mud Mount Kits for the TPS-6X-DSW NOTE: The illustrations in this procedure show the installation of the MMK-6X-DSW with the PMK-6X-DSW. Even though the illustration s only show the PMK-6X-DSW, they are id entical for the BB-6X-DSW.
Mud Mount Kits for the TPS-6X-DSW Crestron MMK/WMKM-6X-DSW Insert and Secure Mud Ring Plate into PMK-6X-DSW (or BB-6X-DSW) PMK- 6 X-D SW DRYWA L L M UD RING P L AT E (2022809 ) DRYWA L L S CREWS ( NO T INCL UDE D ) SCRE W L E NG T H SHO UL D NO T EXCEED D R YWAL L THICKN ESS BY MO RE THAN 1 /2 " ( 1 3 M M) .
Crestron MMK/WMKM-6X-DSW Mud Mount Kits for the TPS-6X-DSW 9. Apply dryw all joint compound as need ed to finish the cutout. Avoid covering t he four tapped mounting holes. 10. Run the necessary cables for t he TPS- 6X-DSW and secure them behind the drywall.
Mud Mount Kits for the TPS-6X-DSW Crestron MMK/WMKM-6X-DSW CAUTION: All ow an air gap of at least 12 inches ( 30.48 cm) in the wall cavi ty above and below the TPS -6X-DSW for heat dissipation. 1. Insert the two pin s on one ad justment plate into the top two outer holes on the mounting plate, as shown in the illustration below.
Crestron MMK/WMKM-6X-DSW Mud Mount Kits for the TPS-6X-DSW NOTE: Make the c utout as level as possible. T he mounting plate allows f or only minor levelin g adju stments. 6. Use the drywal l saw or equi valent and t he include d drywall cutout template to produce an accu rate and level cutou t in the drywall.
Mud Mount Kits for the TPS-6X-DSW Crestron MMK/WMKM-6X-DSW Bend Flanges – 1 of 4 Flanges Bent BA CK O F DRYWA L L 10. Use four standard dry wall scre ws (len gt h sh oul d not exceed dryw al l thickness by more tha n 1/2 inch) to secure th e mud ring plate to the adjustment/m o unting plate assem bly .
Crestron MMK/WMKM-6X-DSW Mud Mount Kits for the TPS-6X-DSW TPS-6X-DSW Mounting Using WMKM-6X-DSW – Exploded View S C R E W # 06 -32 1 1 / 2" P A N H E A D (2007254 ) DRYWA L L SCREWS (NO T I NCL UDED ) SCRE W L ENG TH S HO UL D NO T EXCEED D RYW ALL THICKN ESS BY MO R E T H A N 1 / 2" (13 M M ).
Mud Mount Kits for the TPS-6X-DSW Crestron MMK/WMKM-6X-DSW Resources Industry Compliance As of the date of manufact u re , the MMK-6X-DS W an d W M KM -6 X -D S W have been tested and found to comp ly with specifications for CE marking.
Crestron MMK/WMKM-6X-DSW Mud Mount Kits for the TPS-6X-DSW Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise m a y be returned for credit, excha nge or service with out prior authorization from CR ESTRON. To obt ain warranty serv ice for CRE STRON products, contact an authorized CRESTRON deal er.
Crestron Electronics, Inc. Installation Guide – DOC. 6779A 15 Volvo Drive Rockleigh, NJ 0764 7 (2023087) Tel: 888.CRESTRON 01.09 Fax: 201.767.7576 Specific ations subj ect to www.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Crestron electronic TPS-6X-DSW è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Crestron electronic TPS-6X-DSW - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Crestron electronic TPS-6X-DSW imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Crestron electronic TPS-6X-DSW ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Crestron electronic TPS-6X-DSW, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Crestron electronic TPS-6X-DSW.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Crestron electronic TPS-6X-DSW. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Crestron electronic TPS-6X-DSW insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.