A Crane Co. Company BARNES BARNES ® INST ALLA TION and OPERA TION MANU AL Submer sible Non-Clog Pump IMPORT ANT! Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product improvement program, product changes may occur .
2 T ABLE OF CONTENTS SAFETY FIRST ............................................................................................... 3 A. PUMP SPECIFICA TIONS ................................................................................4 B. GENERAL INFORMA TION .
3 Please Read This Before Installing Or Operating Pump. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS . T o help recognize this information, observe the following symbols: .
4 DISCHARGE ...................... 8” NPT , 125 lb. Flange Horizontal LIQUID TEMPERA TURE ... 104°F (40°C) Continuous VOLUTE ............................. Cast Iron ASTM A-48, Class 30 with Cast Iron Wear Ring MOTOR HOUSING ............. Cast Iron ASTM A-48, Class 30 SEAL PLA TE .
5 SECTION B: GENERAL INFORMA TION B-1) T o the Purchaser: Congratulations! Y ou are the owner of one of the fi nest pumps on the market today . CP&S pumps are products engineered and manufactured of high quality components.
6 If a rigid conduit is used to install the pump it must meet Class I, Division 1 requirements of the National Electrical Code. Conduit must be stainless steel or coated metal, resistant to sewage water .
7 MODEL NO "A" DIM HP V OL T/ Ph Hz RPM (Nom) NEMA ST ART CODE FULL LOAD AMPS LOCKED ROTOR AMPS CORD SIZE CORD TYPE CORD O.D . ± .02 (.5) in (mm) WINDING RESIST ANCE MAIN 8XSE20048HA 49.06 20 460/3 60 870 G 27.8 141.0 8/4 SOW 0.985 (25) .76 8XSE20058HA 49.
8 W ARRANTY NOTE: Both the temperature sensor and moisture detection system must be connected to the motor circuitry such that the motor will be de-energized or sound alarm if excessive motor temperatures are reached and/or if water is detected in the seal chamber and/or motor chamber .
9 TYPICAL THERMAL PROTECTION WIRING DIAGRAM FIGURE 2 FIGURE 3.
10 D-3.2) Insulation T est: Before the pump is put into service, an insulation (megger) test should be performed on the motor . The resistance values (ohms) as well as the voltage (volts) and current (amps) should be recorded on the start-up report. D-3.
11 F-2.1) Disassembly and Inspection: T o expose outer shaft seal (13) for examination, remove Impeller and V olute per Section F-1.1. Set motor assembly (2) in the up position to prevent loss of oil. Remove snap ring from motor shaft, then retaining ring (13D), spring (13C) and rotating member (13B) from shaft, See Fig.
12 TROUBLE SHOO TING CA UTION ! Always disconnect the pump from the electrical power source before handling. If the system fails to operate properly , carefully read instructions and perform maintenance recommendations.
13 FIGURE 7.
14 FIGURE 8.
15 P ARTS LIST ITEM QTY P ART NO. DESCRIPTION 1 1 084851 V olute Assembly 1A 1 079698 * V olute 1B 4 005810 * Nipple 1C 4 014256 * Nipple Cap 1D 8 079380 * Soc.
16 PUMP MODEL T ABLE 1 - MOTOR WITH V ARIOUS CORD LENGTHS 25FT 30FT 40FT 50FT 75FT 100FT 8XSE20048HA 079688 079688XC 079688XE 079688XF 079688XH 079688XL 8XSE20058HA 095171 095171XC 095171XE 095171XF 0.
17 RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A “RETURNED GOODS AUTHORIZA TION”. CONT ACT YOUR LOCAL CRANE PUMPS & SYSTEMS, INC. DISTRIBUT OR. Products Returned Must Be Cleaned, Sanitized, Or Decontaminated As Necessary Prior T o Shipment, T o Insure That Employees Will Not Be Exposed T o Health Hazards In Handling Said Material.
18 A Crane Co. Company 420 Third Street 83 West Drive, Bramton Piqua, Ohio 45356 Ontario, Canada L6T 2J6 Phone: (937) 778-8947 Phone: (905) 457-6223 Fax: (937) 773-7157 Fax: (905) 457-2650 www .
19 Notes.
20 Notes.
21 ST ART -UP REPORT FOR SUBMERSIBLE PUMPS This form is designed to provide assurance that customer service and a quality product are the number one priority with Crane Pumps & Systems, Inc (CP&S). Please fi ll out the following questions as completely and accurate as possible.
22 CP&S control panel part no. and brand Number of pumps operated by control panel NOTE: At no time should holes be made in top of control panel, unless proper sealing devices are utilized.
FOLD HERE AND T APE, DO NOT ST APLE **IMPORT ANT!** WARRANTY REGISTRA TION CUST OMER’S NAME D A TE INST ALLED ADDRESS CITY ST A TE ZIP PHONE # F AX # DEALER’S NAME CITY ST A TE ZIP MODEL NO. SERIAL NO. P ART NO . BRAND IMPORT ANT! W ARRANTY REGISTRA TION Y our product is covered by the enclosed W arranty .
CRANE PUMPS & SY STEMS, INC . WARRANTY SER VICE GR OUP 420 THIRD STREET PIQU A, OHIO 45356 - U .S.A. FOLD HERE AND T APE, DO NOT ST APLE PLACE ST AMP HERE.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Crane Plumbing 8XSE-HA è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Crane Plumbing 8XSE-HA - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Crane Plumbing 8XSE-HA imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Crane Plumbing 8XSE-HA ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Crane Plumbing 8XSE-HA, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Crane Plumbing 8XSE-HA.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Crane Plumbing 8XSE-HA. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Crane Plumbing 8XSE-HA insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.