Manuale d’uso / di manutenzione del prodotto Agilent 86100B del fabbricante Agilent Technologies
Vai alla pagina of 90
Agilent 8610 0B W ide-Bandwidth Oscilloscope Quick Start Guide.
ii Notices © Agilen t T ech nologie s, Inc. 2000-20 03 No pa rt of t his man ual ma y be r epro- duced in any form or by any means (including electronic stor age and retrieval or translation into a foreign lan- guage ) witho ut pri or agre emen t and wr it- ten consent from Ag ilent T echnologies , Inc.
Contents Contents-1 1 Setting Up the Infiniium DCA Step 1. Insp ect t he Sh ipment 1–5 Step 2. Instal l any Modu les 1 –9 Step 3. Cons ider E nviron mental S pecifi cations 1–10 Step 4. Connect the Keyboard and Mouse (Opti onal) 1–11 Step 5. Connect the Line Cord 1–12 Step 6.
Conte nts -2 Conte nts Hiding the H elp 4–8 Print ing the Cont ents of a T opic 4–9 Selecting the Help Languag e 4–10 5 Regula tory Informa tion Compliance with German Noise Requir ements 5–2 .
1 Step 1. Insp ect t he Ship ment 1-5 Step 2. Instal l any Modu les 1-9 Step 3. Cons ider E nviron mental S pecifi cations 1-1 0 Step 4. Connect the Keyboard and Mouse (Opti onal) 1 -11 Step 5. Connect the Line Cord 1-12 Step 6. Turn on th e line powe r 1-15 Step 7.
1-2 Setting Up th e Infi niium D CA Setting Up the In finiium DCA Setting Up the Infiniium DCA This chap ter s hows you h ow to pro perly s et up y our Infini ium DCA . Foll ow the setup s teps i n the order prese nted. I n addi tion, y ou will learn how t o use proper optical connection clean ing techniq ues to avoid cos tly repairs.
1-3 Setting U p the Infini ium DCA General Sa fety Consid erations WAR NI N G If this produc t is not used as spe cified , the prot ection pr ovided by the equipmen t could be impaire d. This produ ct must be used in a n ormal condi tion (i n which a ll mea ns for pr otect ion are i ntact ) only.
1-4 Setting Up th e Infi niium D CA Instrument Markin gs Instrument Markin gs The in struct ion man ual s ymbol . The produc t is m arked w ith t his wa rn- ing symb ol wh en it is nec essa ry for the us er to refer to t he ins tructi ons in the ma nual.
1-5 Setting U p the Infini ium DCA Step 1 . Inspec t the S hipment Step 1. Inspect the Shipment Inspect the shipping container for damage. Inspect the instr ument.
1-6 Setting Up th e Infi niium D CA Options and Access ories NOTE Keep t he ship ping contai ner and cu shioning material until you have inspected the contents of th e shipment for completene ss and have checked t he instrument mechanically and electrically .
1-7 Setting U p the Infini ium DCA Options and Acce ssories Tabl e 1- 3. Opti onal Ac cess orie s Accessory Desc ription 10086A ECL termi nator 11667B Power split ter, dc to 26.
1-8 Setting Up th e Infi niium D CA Options and Access ories Table 1-5. Fi ber-Opt ic Adapters for Opt ical Chan nels Front Pan el Fiber-Optic Adapte r Descr iption Agilen t Part Numb er Diamond HMS -.
1-9 Setting U p the Infini ium DCA Step 2. Instal l any Mo dules Step 2. Install any Modules Up to two modul es can be ins erted in to the Inf iniium DCA . All docu mentation (incl uding specif icatio ns) fo r plu g-in mo dules is loca ted in t he Inf iniium DCA’ s Help s ystem.
1-10 Setting Up th e Infi niium D CA Step 3. Consider En viron mental Spe cificatio ns Step 3. Consider Environmental Specifications Review th e follo wing speci ficati ons to ens ure that your operat ing or sto rage envi ronment is su itable for th e inst rumen t.
1-11 Setting U p the Infini ium DCA Step 4. Conn ect t he Keybo ard and Mouse (Optiona l) Step 4. Connect the Keyboard and Mouse (Optional) Connect the s tandard P C-compati ble mouse and keyboar d that is suppl ied with the ins trument. NOTE Do not stack other objects on the keyboard; this will cause self-test failures on power -on.
1-12 Setting Up th e Infi niium D CA Step 5. Co nnect t he Line Cord Step 5. Connect the Line Cord Connec t t he l ine c ord as sho wn i n th e figu re b elow . The I nfini ium DCA au tomatica lly a djusts f or lin e input volta ges in t he ran ge of 100 to 240 V AC.
1-13 Setting U p the Infini ium DCA Step 5. Connect the Line Cor d only a stan dby swi tch an d is n ot a L INE sw itch. Altern ativel y , a n exte rnally inst alled switch or cir cuit b reake r (whic h is rea dily i dentifi able a nd is easil y reach ed by th e opera tor) may be used as a d isconn ecting device.
1-14 Setting Up th e Infi niium D CA Step 5. Co nnect t he Line Cord 250V 8120- 1689 8120-1 692 8120-2 857p Stra ight * CEE7-Y11 90° Strai ght (S hiel ded) 79/200 79/200 79/200 Mint Gra y Mint Gra y Coco Brown East and Wes t Europe, Saudi Ar abia , So.
1-15 Setting U p the Infini ium DCA Step 6. T urn on the line po wer Step 6. Turn on th e line power Press the p ower switch at th e lower left -hand corner of the fron t pane l. After a bout one minu te, the Infi niiu m DCA wi ll be read y to use. The disp lay will look similar to the following figure .
1-16 Setting Up th e Infi niium D CA Interac ting With t he Disp lay NOTE The detac hable power co rd is the instrumen t discon necting device . It dis connects the mains circuits from the mai ns power sup ply before other parts of the in strument. T he front panel switch is only a standby switch and is not a LINE switch disconnecting device.
1-17 Setting U p the Infini ium DCA Step 7. S et th e tim e and da te Step 7. Set the time and date 1 T ouch the curr ent time and date sho wn near the top of the displ ay .
1-18 Setting Up th e Infi niium D CA Step 8. Conn ect a P rinter Step 8. Connect a P rinter Use of a pr inte r with the Infinii um DCA is opt ional. Ta b l e 1 - 9 list s th e PC L-lan- guag e prin ters t hat are cu rrent ly sup ported for u se wi th th e inst rument .
1-19 Setting U p the Infini ium DCA Step 8. Connect a Prin ter 3 Turn the po wer o ff the Infi niium D CA. Do not exit t he onli ne H elp bef ore turn ing the ins trument o ff. 4 Connec t the pr inte r to the ins trumen t’s rear-p anel Parallel port.
1-20 Setting Up th e Infi niium D CA Step 8. Conn ect a P rinter 10 Selec t Local print er and then touch Next . 11 Select the print er manufactur er and then print er.
1-21 Setting U p the Infini ium DCA Step 8. Connect a Prin ter 13 Touch Ye s and then touch Next . 14 Touch Ye s to print a tes t page . Then , touc h Nex t . 15 After confi rming that the test pa ge p rinte d cor rectly, tou ch Ye s . 16 Turn the In finiiu m DCA’ s power off a nd th en on again .
1-22 Setting Up th e Infi niium D CA Step 9. Calibra te the T ouch S creen Step 9. Calibrate the Touch Screen The tou ch screen conf igura tion uti lity ensu res that the touch scre en is bot h align ed and o rient ated wit h the displa y .
1-23 Setting U p the Infini ium DCA Step 1 0. Con figure th e Instr ument on a L AN Step 10. Configure the Instrument on a LAN Y ou can conf igure this i nstrume nt on a LAN for f ile shari ng an d using network printer s.
1-24 Setting Up th e Infi niium D CA Step 11. Avoi d Costl y Repa irs Step 11. Avoid Costly Repairs CAUTIO N Ele ctrical channel inpu t circuit s and the trigge r inpu t c ircuit can be d amage d by e lectros tati c disc harge (ESD). T heref ore, a void ap plyin g sta tic dis charge s to the front-pan el input connectors .
1-25 Setting U p the Infini ium DCA Step 11. Avoid C ostly R epair s and compromi sed measure ments. Bef ore you connect any fibe r -opti c cable to the Infini ium DCA, refer to “Clean ing Conne ctions for A ccurate Measurem ents” on p age 1- 30 .
1-26 Setting Up th e Infi niium D CA Step 12. Perf orm a Module Calib ration Step 12. Perform a Module Calibration A modu le cali brati on estab lis hes cali brat ion factor s for all in sta lled mod ules .
1-27 Setting U p the Infini ium DCA Step 12. Perform a Mod ule Calibration T o perform a module calib ration 1 On t he Calibrate men u, choose All Calibratio ns . The All Cali bratio ns dial og box opens . Thi s dia log bo x allow s you to view the ca libra tion st atus of mod ules an d ini tiate t he cal ibrati on.
1-28 Setting Up th e Infi niium D CA Step 12. Perf orm a Module Calib ration modu le cal ibra tion is va lid. ”.
1-29 Setting U p the Infini ium DCA Step 13. For More Information Step 13. For More Information Ther e are se veral w ays to l earn mo re abou t your Infiniiu m DCA. • Cont inue r eading this book . Cha pter 3 , “Usin g the In finiium DCA” w ill hel p you get sta rted using th is ins trument .
1-30 Setting Up th e Infi niium D CA Clea ning Co nnecti ons for Accu rate M easur ements Cleaning Connections for Accurate Measurements T od ay , advances in measurement capabilities make connectors and connec- tion techn iques mor e impo rtant than ev er .
1-31 Setting U p the Infini ium DCA Choos ing the Right C onnecto r tion s take repea tabilit y uncer taint y into accoun t? • Wil l a con nector degrad e the ret urn l oss too much, o r will a fusi on sp lice be re- quired ? Fo r ex ampl e, man y D FB la sers c annot oper ate w ith refle ctions from connecto rs.
1-32 Setting Up th e Infi niium D CA Choo sing th e Right Conn ector Figure 1-2. Universal adapters to Diamond HMS-10. The HM S-10 en cases th e fibe r withi n a soft n ickel silver ( Cu/Ni/Z n) ce nter which is sur rounded by a toug h tungste n carbide cas ing, as shown in Figure 1-3 .
1-33 Setting U p the Infini ium DCA Insp ecting C onnec tors glas s face is not affec ted, sc ratch es or gr it can ca use the g lass fi ber to move out of a lignmen t. A lso, if unkeye d c onnect ors ar e used , the nicke l sil ver ca n be pushed on to the glas s surface.
1-34 Setting Up th e Infi niium D CA Inspec tin g Conn ector s Figure 1-4. Clean, pro blem-free f iber end and ferrul e. Figure 1-5. Dirty fiber end and f errule from poo r cleaning. Figure 1-6. Damage from improp er cleaning . While t hese often w ork we ll on fi rst in serti on, th ey are g reat di rt ma gnets .
1-35 Setting U p the Infini ium DCA Insp ecting C onnec tors nectors, using small glass spheres . When used with contacting connect ors, these glass balls can s crat ch an d pit the f iber . I f an i ndex ma tchi ng gel or oi l must be us ed, appl y it to a freshly cle aned conne ctor , make the measurem ent, and then im medi ately clean it off .
1-36 Setting Up th e Infi niium D CA Clea ning Co nnecto rs duce a go od retur n-loss measurem ent. The qua lity of the polis h estab lishes the differe nce between the “PC” (physi cal contact) and the “S uper PC” con- nectors.
1-37 Setting U p the Infini ium DCA Clea ning Co nnect ors T o c lean a n on-l ensed conne ctor CAUTIO N Do not us e any t ype of f oam swa b to clea n opti cal f iber en ds. Foa m swabs c an leave film y deposits on fi ber ends that can de grade per formance .
1-38 Setting Up th e Infi niium D CA Clea ning Co nnecto rs filter ed, d ry, c ompre ssed a ir. A im the comp ress ed ai r at a shal low angl e to t he fiber end face .
1-39 Setting U p the Infini ium DCA Returning the In strument for Servic e Returning the Instrument for Service The instr uctio ns in t his s ecti on sho w you ho w to p rop erly pack age th e i nstru- ment fo r return to a Agile nt T echn olo gies se rvice o ffice .
1-40 Setting Up th e Infi niium D CA Prep aring th e inst rumen t for shippin g infor matio n sho uld be r eturn ed wi th th e in strum ent. • Typ e of servic e required . • Date instrum ent was ret urned for repai r. • Descripti on of the proble m: • Whet her p robl em is co nstant or i nter mitten t.
1-41 Setting U p the Infini ium DCA Prep aring th e instru ment for shi pping Sealed Air Corpor ation (Commerc e, California 90001). Air Cap looks like a plast ic shee t filled with ai r bubbl es. Us e the pink (antist atic) Air Cap ™ to redu ce stat ic elec tricit y.
1-42 Setting Up th e Infi niium D CA Hard Dri ve Reco very Hard Drive Recovery The I nfin iium DCA hard d rive recove ry syst em of fers a way to rec over f rom situatio ns when the in strume nt hard d rive con figurati on becomes corrup t due to inad vert ent use r chan ges to th e inst rument or to a virus infec tion .
1-43 Setting U p the Infini ium DCA Agilen t T echno logies Service O ffices Agilent Technologies Service Offices Call Cente r For technical assistance, you can contact yo ur local Agilent Call Center . • In the Americas, call 1 (800) 452-4844 • In other regions, visi t http://www.
1-44 Setting Up th e Infi niium D CA Servi ce C enter.
2 Workin g in Com fort.
2-2 Workin g in Comfort Work ing in Comfort Working in Comfort T o optimize y our comfort and product ivity , it is i mportant that you set up your work ar ea cor rectl y and use yo ur Agi lent pro duct pr oper ly .
2-3 Working in Comfort Mice a nd Othe r Input Devices RSI ha s al so b een obs erved in those wh o fre quen tly enga ge i n ac tivit ies such as c arpent ry , knit ting , hou sework , gard ening , tenn is, wi ndsur fing and lif ting chil dren. What causes RSI? The s pecific caus es of RS I have not been es tablish ed.
2-4 Workin g in Comfort Mice and Oth er In put Dev ices in your hands, wr ists, and forear ms. • If you ar e usin g a s crollin g mous e, be sure to ke ep your finge rs an d hand in a rel axed, ne utr al posi tion when activ atin g the scroll wheel.
3 Introducti on 3-2 Oscill oscope M ode 3-8 Eye/M ask Mode 3-7 TDR/ TDT Mod e 3-9 Using Pl ug-in Mo dules 3-10 Using th e Touch Sc reen 3-1 2 Using the Qu ick Measure Featu re 3-13 If the D isplay Goe.
3-2 Usi ng the In finii um DC A Introduct ion Introduction The Infinii um D CA i s desi gned to measu re a var iety of h igh spee d digi tal c om- munica tion wav eforms.
3-3 Using th e Infini ium DCA Introduc tion Use the tou ch screen Y ou can e xplore the instrum ent’ s menus and c hange its s ettin gs by touch ing the display . Notice that the measur ement toolbar chang es depending on the select ed i nstrum ent m ode.
3-4 Usi ng the In finii um DC A Introduct ion Refer to the H elp System T o learn how to us e your Infi niium D CA and to lo cate infor mation on s pecifi ca- tions (i ncluding p lug-i n modul es), i nstrument featu res, a nd meas urement configur ation refe r to Chapter 4, “Us ing the Bu ilt-In Infor mation S ystem” in this book.
3-5 Using th e Infini ium DCA Introduc tion Front- panel f eatures The fol lowin g figu re shows the inp ut conn ect ors, con trol s, powe r switc h, and othe r fro nt-pa nel f eatur es ava ilabl e on t he In finii um DCA .
3-6 Usi ng the In finii um DC A Introduct ion Rear -panel features The fol lowin g figu re show s the rear - pan el inpu t connec tio ns avai labl e on the Infi niium DCA.
3-7 Using th e Infini ium DCA Eye/Ma sk M ode Eye/Mask Mode The Eye/M ask m ode a llo ws yo u to per- form NRZ (Non-R eturn to Zero), or RZ (Return to Zero) eye diagram measure- ments a nd eye m ask test s. The ey e dia- gram is ty picall y pro duced by trigg erin g the i nstru ment wi th a synch rono us clock signal.
3-8 Usi ng the In finii um DC A Oscillos cope Mode Oscilloscope Mode Use th e Osci llosc ope mod e for pulse type wav eforms that are t riggered by an exte rnal si gnal . Osci llosc ope mod e measurements on ly work when a sing le valued wa veform , an d no t an eye d ia- gram , is prese nt o n t he s creen .
3-9 Using th e Infini ium DCA TDR/ TDT M ode TDR/TDT Mode The TDR /TDT mo de allo ws you us e time do main reflec tometry (TD R) to veri fy t he pr oper f unct ionin g of the physical com ponents of yo ur device unde r test usin g a time-d elayed ele ctri- cal pulse .
3-10 Usi ng the In finii um DC A Using Plu g-in Modu les Using Plug-in Modules The Inf iniium DCA holds up to two plug-in modules , which can pro vide up to four measureme nt channels. Each input channel has its own vert ical controls. The am plitud e sca le kno b adju sts th e ampl itude s cale us ed for t he in put ch an- nel.
3-11 Using th e Infini ium DCA Using Plug -in Module s Y ou can use 83 48x and 5475x s eries plug-i n modules In ad ditio n to a complet e line of mo dules design ed spec ific ally fo r thi s instru - ment, module s designed for us e with HP/Agil ent 83480A and 54750A main- frames can also be inst alled int o the In finiium DCA.
3-12 Usi ng the In finii um DC A Using the Touch Scre en Using the Touch Screen Ther e may be ti mes wh en you would lik e to disab le th e touch sc reen fe ature. For ex ample, when pointi ng ou t a me asuremen t res ult wit hout in itia ting a chan ge to the ins tru ment.
3-13 Using th e Infini ium DCA Using the Qui ck Meas ure Feat ure Using the Quick Me asure Feat ure Press Quick Measure and t he Infi niium DCA au tomatic ally pe rform s fou r measurem ents on a dis played si gnal. Y ou can conf igure Qu ick Measure to inclu de any fo ur mea surem ents located on the meas urem ent to ol bar .
3-14 Usi ng the In finii um DC A If the Display Go es Bla nk If the D isplay G oes Blan k The d isplay auto maticall y turn s of f if t he Inf inii um DCA i s power ed ov er an eight hour pe riod w ithou t being u sed. Th e purpo se of th is fea ture is to exten d the li fe of the disp lay .
3-15 Using th e Infini ium DCA Hidin g and Mo ving Dialog Bo xes Hiding and Moving Dialog Boxes Somet imes, dia log boxe s may cover po rtio ns of a disp layed signal and gr ati- cule that y ou wis h to see. Y ou ca n eith er m ove th e dia log b ox o r make it trans- parent.
3-16 Usi ng the In finii um DC A Menus Menus The in strume nt men us provid e acc ess to al l functi ons. Thi s secti on show s the layou t of e ach me nu.
3-17 Using th e Infini ium DCA Menus The Co ntro l me nu.
3-18 Usi ng the In finii um DC A Menus The Setup menu.
3-19 Using th e Infini ium DCA Menus The Me asur e menu The Calibrate menu.
3-20 Usi ng the In finii um DC A Menus The Ut ili ties menu The Help menu.
4 The Infi niium DCA He lp Contents 4-3 Descri ption of th e Conten ts Topics 4-4 Getti ng He lp Wh ile C hangi ng Instru ment S ettin gs 4-6 Learning About Measu remen ts Results 4-7 Hiding the H elp.
4-2 Using the Buil t-In Informa tion System Using the Buil t-In Informatio n Syst em Using the Built-In Information System Wher e is the oper ating man ual for your infin iium DCA ? I t is built into yo ur inst rument! T o access the bu ilt-in informa tion s ystem, refe rred t o as H elp, simply touch Conten ts on the Help menu.
4-3 Using th e Built-I n Informa tion System The Infi niium DCA Help Conte nts The Infiniium DCA Help Cont ents The follow ing figure shows the 86100B Help cont ents.
4-4 Using the Buil t-In Informa tion System Descri ption of the Content s Topi cs Description of the Contents Topics The f ollow ing l ist de scribe s the info rmation you ca n fi nd in each o f the c on- tents t opics. Gettin g Started This to pic contains links to us eful inf ormation you may want to re ad first.
4-5 Using th e Built-I n Informa tion System Descr ipti on o f th e Co ntent s T opi cs Connector Care This topic provides infor matio n about op tica l and elec - trical connector care. Managing Fi les and Networks This topi c pro vide s info rmati on a bout file managem ent, usin g your netw ork, and pr inti ng.
4-6 Using the Buil t-In Informa tion System Getting Help Wh ile Chang ing Instru ment Setti ngs Getting Help While Changing Inst rument Settings Help is a vaila ble dire ctly from dial og b oxes in t he g rap hical user inte rfac e. • To se e ove rview inf ormat ion in an open d ialo g box, touc h the Book icon.
4-7 Using th e Built-I n Informa tion System Learni ng Abou t Meas ure ments Res ult s Learning About Measurements Results After a measur eme nt is perfor med, th e dis plays shows t he Me asure tab w hich inclu des the measure men t results .
4-8 Using the Buil t-In Informa tion System Hiding th e Help Hiding the Help When using t he Help , you can temp oraril y hide it so that you ca n see the entir e displa y . Then, you can re-d isplay t he Help wi th the same top ic still showi ng. • To hide the H elp, touch t he Minimize bu tton loca ted at the top of the He lp window.
4-9 Using th e Built-I n Informa tion System Print ing th e Cont ents of a T op ic Printing the Contents of a Topic Y ou can prin t the entire contents o f a Help t opic or a pop-up wi ndow . T o print the en tire con tents of a Hel p top ic, s imp ly to uch t he Print butt on locat ed at the top of the H elp window.
4-10 Using the Buil t-In Informa tion System Selec ting t he Help Langua ge Selecting the Help Langu age Help is availabl e in more than one language . On the Help me nu, to uch Select Help Languag e, and then tou ch the lan guage you want to vie w . Pleas e ensu re that the Help file is clos ed be fore cha nging the lang uage se lecti on.
5 Regulato ry Informa tion.
5-2 Regulat ory Informa tion Compli ance wi th Ge rman Nois e Requi reme nts Compliance with German Noise Requirements Th i s is to d e cl a re t ha t t hi s i ns t ru m en t is i n c on f or m a nc e wi t h t h e G er m a n R e g- ulation o n Noise Declaration for Machi nes (Laerman gabe nach der Maschi nen- laermr eror dnun g -3.
5-3 Regulator y Inform ation Declara tion of Conformity - Mainframe Declaration of Conformity - Mainframe.
5-4 Regulat ory Informa tion Declar ation of Confo rmity - Plug -in Module s Declaration of Conformity - Plug-in Modules.
Index Index- 1 Numerics 12 GH z trig ger ba ndwi dth , 1–6 5475x series plug-in modules , 3–11 8348x series plug-in modules , 3–11 A accessories connecting , 1–11 adapters APC 3.
Index -2 Index instrument modes , 3–2 ISM1-A , 1–4 isopro pyl a lcohol , 1–37 K keyboa rd , 1–6 , 1–11 L LAN , 1–23 langua ge versio n , 4–1 0 line co rds , 1–13 line po wer requiremen.
Index- 3 Index U Utilitie s m enu , 1–2 2 W warm-up time , 1–26 Web s ite, A gilent , 1–29 weight , 1–10 What’ s this? ic on , 4–6 wire bai l, positi oning , 1–11.
Index -4 Index.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Agilent Technologies Agilent 86100B è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Agilent Technologies Agilent 86100B - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Agilent Technologies Agilent 86100B imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Agilent Technologies Agilent 86100B ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Agilent Technologies Agilent 86100B, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Agilent Technologies Agilent 86100B.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Agilent Technologies Agilent 86100B. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Agilent Technologies Agilent 86100B insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.