Oct. 2005, Rev. 9 UL325 COMPLIANCE REQUIRES THE USE OF CONT ACT EDGES OR PHOTOELECTRIC CONTROLS ON ALL AUTOMA TIC OR REMOTEL Y -CONTROLLED GA TE OPERA TORS.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 2 - TABLE OF CONTENTS PRE-INST ALLA TION INFORMA TION Gate Operator Classifications .....................................................................................................................
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 3 - Read the following before beginning to install OSCO slide gate operators: 1. Read the yellow “Safety Instructions” brochure enclosed with the packet of information. If you do not have one, please call OSCO at 1-800-333-1717 to request one.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 4 - 10-04-6 WIRING SPECIFICATIONS 1. Select from the chart at the bottom of this page corre- sponding to the model, voltage and horsepower rating of your operator . 2. The distance shown on the chart is measured in feet from the operator to the power source.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 5 - PAD MOUNTING INSTRUCTIONS FOR MODELS SLR, SLC & SLD Before installing, make sure the gate rolls or slides freely , and that all exposed rollers are properly covered.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 6 - GATE BRACKET AND CHAIN ASSEMBLY INSTRUCTIONS Assemble a gate bracket (1) to the front edge of the gate, using two U-bolts (2), and mounting hardware (3). Before tightening down completely , be sure the bracket is p arallel to the gate.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 7 - VENT PLUG INSTALLATION Gear reducers used in OSCO gate operators will have solid plugs installed prior to shipment in order to keep the oil inside fro m spilling out during shipping. A vent plug has been provided to replace this plug during installation.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 8 - ELECTRICAL CONNECTION AND ADJUSTMENTS All OSCO gate operators are supplied with a power disconnect switch to turn on and off the power supply available to the operator .
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 9 - Auto Close Timer Adjustment: This 270-degree adjustable potentiometer will signal the operator to close automatically , provided no open, reversing or obstruction signals are present from the fully-open position.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 10 - Y ou must follow all required safety precautions and instructions at all times. Review the safety brochure included with the operator . If any pages are missing or unreadable, cont act OSCO at 1-800-333-1717 to request additional copies.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 11 - CURRENT SENSING ADJUSTMENTS Because gates vary in construction and may have different force requirements in the open and close directions to move, the OSCO control board has separate Multi-turn potentiometers for adjusting in both directions independently .
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 12 - ONBOARD L.E.D. INDICATOR DESCRIPTIONS Control Board L.E.D. Indicators: OPEN This indicator is lit when an open signal is present. This signal can come from such devices as button stations, radio receivers, keypads and telephone entry systems.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 13 - IMPORTANT NOTES FOR INSTALLATION OF MASTER/SLAVE APPLICATIONS When setting up Master/Slave gate operators, it is best to make adjustments and run each operator individually . T o do this, simply: a.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 14 - CHARGER BOARD SLEEP MODE When primary AC power is not available, the operator will continue to operate in battery only mode if the charger board is set in its RUN mode ( see Battery Backup Charger Configuration ).
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 15 - CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 16 - CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 17 - CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 18 - 12-06-12 CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS AC MODELS ONL Y.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 19 - LOOP LAYOUT ILLUSTRATION Refer to Connection Descriptions on page 10 and Loop Accessory Connections on page 18 for details.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 20 - EDGE LAYOUT ILLUSTRATION #1 Refer to Connection Descriptions on page 10 and Contact Edge Connections on page 17 for details.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 21 - EDGE LAYOUT ILLUSTRATION #2 Refer to Connection Descriptions on page 10 and Contact Edge Connections on page 17 for details.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 22 - PHOTO EYE ILLUSTRATION Refer to Connection Descriptions on page 10 and Photo Eye Connections on page 17 for details.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 23 - PICKET GATE ILLUSTRATION Refer to Connection Descriptions on page 10 and Accessory Connections on pages 15-18 for additional details.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 24 - TRACK GATE ILLUSTRATION.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 25 - TROUBLESHOOTING Operator fails to start: A . If the operator has been running a large number of cycles, the motor may have gotten hot and tripped the overload. Allow the motor to cool down and the overload will reset automatically .
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 26 - MODEL SLR MECHANICAL PARTS EXPLODED VIEW 10-04-6.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 27 - MODEL SLR MECHANICAL PARTS LIST REF NO. P ART NO. DESCRIPTION 1 2300-907 Operator Cover 2510-354 Plunger Reset Assembly 2500-2240 Plunger Reset B.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 28 - MODEL SLC MECHANICAL PARTS EXPLODED VIEW 10-04-6.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 29 - MODEL SLC MECHANICAL PARTS LIST REF NO. P ART NO. DESCRIPTION 1 2300-907 Operator Cover 2510-354 Plunger Reset Assembly 2500-2240 Plunger Reset B.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 30 - 10-04-6 MODELS SLR • SLC CONTROL BOX PARTS LIST REF NO. P ART NO. DESCRIPTION 1 2100-1778-PL T Control Box Wrapper 2 2100-1762 T erminal S trip Bracket, output side 3 2100-1761 T erminal S trip Bracket, input side 4 2300-735 Heyco Bushing, 1.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 31 - MODEL SLD MECHANICAL PARTS EXPLODED VIEW 10-04-6.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 32 - MODEL SLD MECHANICAL PARTS LIST REF NO. P ART NO. DESCRIPTION 1 2300-907 Operator Cover 2510-354 Plunger Reset Assembly 2500-2240 Plunger Reset B.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 33 - 10-04-6 MODEL SLD CONTROL BOX PARTS LIST REF NO. P ART NO. DESCRIPTION 1 2100-1778-PL T Control Box Wrapper 3 2100-1762 T erminal S trip Bracket, output side 4 2100-1761 T erminal S trip Bracket, input side 5 2200-122 Heyco Bushing, .
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 34 - BATTERY MAINTENANCE The gel-cell batteries in this operator require no routine maintenance. For assured continued performance, they should be replaced every year .
MA TERIAL SAFETY DA T A SHEET MOBIL SHC 634 1 . PRODUCT AND COMP ANY IDENTIFICA TION PRODUCT NAME: MOBIL SHC 634 SUPPLIER: EXXONMOBIL CORPORA TION 3225 GALLOWS RD.
sso 3 Imperial Oil MA TERIAL SAFETY DA T A SHEET Date Prepared: June 12, 1997 Supersedes: February 02, 1996 MSDS Number: 08068 Cette fiche signaletique ast aussi disponible en francais 1. PRODUCT INFORMA TION Product Identifier: ESSO GEAR OIL GX 75W-90 Application and Use: Transmission adn gear lubricant.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 37 -.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 38 - PREVENTATIVE MAINTENANCE GENERAL: OSCO gate operators are designed for many years of trouble-free operation and, under recommended operating conditions, will require only minimal maintenance.
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 39 - This page intentionally left blank..
SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 40 - By signing this installation checklist, I/we hereby certify that each item listed and checked above has been covered by the installer and is clearly understood by the customer .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Cosco SLD è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Cosco SLD - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Cosco SLD imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Cosco SLD ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Cosco SLD, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Cosco SLD.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Cosco SLD. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Cosco SLD insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.