Manuale d’uso / di manutenzione del prodotto ENDURO-175 del fabbricante Cornelius
Vai alla pagina of 18
Installation Manual ICE/BEVERAGE DISPENSER MODEL: ENDURO–175 8 V AL VE IMPORT ANT : TO THE INST ALLER. It is the responsibility of the Installer to ensure that the water supply to the dispensing equipment is provided with protection against backflow by an air gap as defined in ANSI/ASME A1 12.
i 620917902INS T ABLE OF CONTENTS Page SAFETY PRECAUTIONS 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DESCRIPTION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 620917902INS SAFETY PRECAUTIONS This ice dispenser has been specifically designed to provide protection against personal injury and eliminates contamination of ice. T o ensure continued protection and sanitation, observe the following: AL W A YS: disconnect power to the dispenser before servicing or cleaning.
2 620917902INS INST ALLA TION INSTRUCTIONS IMPORT ANT : T O THE INST ALLER. It is the responsibility of the Installer to ensure that the water supply to the dispensing equipment is provided with protection against backflow by an air gap as defined in ANSI/ASME A1 12.
3 620917902INS ICE DIVERTER KIT 02394 NOTE: For dispensing Scotsman, Wilshire, and Hoshizaki compressed ice cubes: 1. Disconnect power to dispenser . 2. Remove Merchandiser from dispenser . 3. Remove ice chute and discard gate restrictor . 4. Install ice diverter on gate mounting plate as shown below .
4 620917902INS GA TE RESTRICTOR PLA TE CAUTION: Disconnect power to dispenser before installing, removing or adjusting restrictor . ADJUSTMENT INST ALL PLA TE ON STUDS AS SHOWN FIGURE 2.
5 620917902INS FIGURE 3. MOUNTING TEMPLA TE 20 15/16 24 1/2 1 13/16 1 5/16 18 5/8 7/16 DIA. 12 9 OPENING 21 1/4 29 3/4 31 5/16 REMOV ABLE SINK 7 15/16 8 5/8 3 1/2 17 1/2 RECOMMENDED COUNTER OPENING SIZE 9” X 12” FOR UTILITIES AND BEVERAGE TUBING. OPENING CAN BE LOCA TED ANYWHERE WITHIN THE SHADED AREA.
6 620917902INS SOL VENT BOND HOSE CLAMP BARB ADAPTER 1 BARB x 3/4 MPT COUPLING 3/4 SOCKET x 3/4 FPT DRIP TRA Y DRAIN FITTING DRAIN LINE 1” I.D. PLASTIC TUBING (6 FT) WITH INSULA TION FIGURE 4.
7 620917902INS S6 INST ALL FOR NON–CARB AS REQUIRED S4 S7 CHECK VA LV E OPTIONAL FOR DIET DRINKS OR ROOT BEER S4 SYRUP T ANKS 15–50 PSIG S8 S3 S2 PRESSURE REGULA TORS S7 S5 S4 S3 S2 S1 W2 S3 W4 W3.
8 620917902INS CHECK VA LV E S5 8 S8 W A TER MANIFOLD 6 S6 SYRUP T ANKS F AUCETS VIEWED FROM FRONT OF UNIT S7 CARB WA TER S4 S3 S2 1 2 3 4 5 7 1 2 3 4 5 6 S1 S2 S3 S4 S5 S6 S1 CARB WA TER 15–50 PSIG.
9 620917902INS W ARNING: If repairs are to be made to a product system, remove quick disconnects from the applicable product tank, then relieve the system pressure before proceeding. If repairs are to be made to the CO 2 system, stop dispensing, shut off the CO 2 supply , then relieve the system pressure before proceeding.
10 620917902INS T rouble Probable Cause BEVERAGE NOT SWEET ENOUGH. A. Empty syrup tank. B. Faucet brix requires adjusting. BEVERAGES NOT COLD (UNITS WITH BUIL T -IN COLD PLA TE). A. Unit standing with no ice in hopper – no ice in cold plate cabinet.
1 1 620917902INS B L A C K B L A C K WIRING DIAGRAM TO 24V TRANSFORMER OPTIONAL KEY SWITCH MOTOR ST ART CAP ACITOR B L A C K R E D R E D BLACK WHITE W H T G R E E N BLUE RED PINK B L A C K BLACK BLACK.
12 620917902INS CAP ACITOR AGIT A TOR MOTOR GA TE SOLENOID OPTIONAL BEVERAGE TRANSFORMER MOTOR HEA TER OPTIONAL LIGHT ST ARTER BALLAST N.O. L N.C. C VEND SWITCH G N TIMER L2 L1 RECTIFIER OPTIONAL ICE LEVEL PCB BOARD OPTIONAL FLA VOR VL VS VL V SOLENOIDS KEYP AD FIGURE 8.
13 620917902INS T’ST A T LIGHT ICE LEVEL SIGNAL OPTION 1 2 DANGER! ELECTRIC SHOCK HAZARD. DISCONNECT POWER BEFORE SER VICING UNIT . SERVICE INFORMA TION GRN/ YEL TO SOLENOID MOUNTING PLA TE OPTIONAL LIGHT SOCKET W H T Y E L L O W B L A C K B L U E TO BEVERAGE P ANEL OPTIONAL LIGHT ST ARTER TO BEVERAGES F AUCET GRN/YEL GRN/YEL WHT LT .
14 620917902INS 220–240V LINE FIL TER EMI FIL TER POWER SWITCH AGIT A TOR MOTOR GA TE SOLENOID OPTIONAL BEVERAGE TRANSFORMER MOTOR HEA TER OPTIONAL LIGHT OPTIONAL ST ARTER OPTIONAL BALLAST N.
15 620917902INS W ARRANTY IMI Cornelius Inc. warrant that all equipment and parts are free from defects in material and work- manship under normal use and service. For a copy of the warranty applicable to your Cornelius prod- uct, in your country , please write, fax or telephone the IMI Cornelius office nearest you.
IMI CORNELIUS INC..
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Cornelius ENDURO-175 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Cornelius ENDURO-175 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Cornelius ENDURO-175 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Cornelius ENDURO-175 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Cornelius ENDURO-175, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Cornelius ENDURO-175.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Cornelius ENDURO-175. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Cornelius ENDURO-175 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.