Manuale d’uso / di manutenzione del prodotto CVF36N del fabbricante Continental Fireplaces
Vai alla pagina of 18
1 W415-0298 / K / 12.06.07 INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER . Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .continentalplaces.com • ask@continentalfire.
2 W415-0298 / K / 12.06.07 PG 3-4 INTRODUCTION W arranty General Instructions General Information Care of Glass Door , Catalytic T iles & Plated Parts 5-7 INST ALLA TION Combustion and V entilatio.
3 W415-0298 / K / 12.06.07 CONTINENTAL® gas fireplaces are manufactured under the strict Standard of the world recogn ized ISO 9001:2000 Qual ity Assurance Certificate. WOLF STEEL LTD. products are designed with superior components and materials , assembled by tr ained craftsmen who take great pride in their work.
4 W415-0298 / K / 12.06.07 Use only accessories designed for and listed with your specifi c fi replace. Early signs of carbon monoxide poisoning resem- ble the fl u, with headache, dizziness and/or nau- sea. If you have these signs, the heater may not be working properly .
5 W415-0298 / K / 12.06.07 ROOM 2 ROOM 1 This hea ter shall not be installed in a confined space or unusually tight constr uction unless pro visions are pr ovided for adequa te combustion and ventila tion air .
6 W415-0298 / K / 12.06.07 Proceed once the vent installation is complete. NOTE: All gas connections must be contained within the fi replace when complete. 1. Move the fi replace into position and secure to the fl oor through the 1/4" holes located at either side of the base.
7 W415-0298 / K / 12.06.07 T o install the fireplace face flush with the finished wall, position the framework to ac- commodate the thickness of the fi nished wall. Bend out the four nailing tabs, attached on either side of the fi replace and secure to the 2x4 framing.
8 W415-0298 / K / 12.06.07 The curtain mesh must be kept fully closed during operation to help prevent accidental burns from occurring. The hea ter must not be used when the hood is r e- mov ed. Hook the hood over the lip of the curtain support plate.
9 W415-0298 / K / 12.06.07 A C B FIGURE14 HOOD Attach the hood by pressing the top fl ange into the clips along the top of the louvre opening. Secure using a screw through the centre slot. A CLIPS CENTRE SLOT FLANGE UPPER LOUVRES Insert the louvre tabs into the slots located at the top left and right corners of the unit.
10 W415-0298 / K / 12.06.07 FIGURE 22 FIGURE 20 Attach the connectors from the black and red wires to the blower . Attach and secure the variable speed switch using the nut provided. Plug the harness cord into the receptacle. The wir e harness pr ovided in this kit is a univ ersal harness .
11 W415-0298 / K / 12.06.07 When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed. 1. STOP! Read the above safety information on this la- bel. 2. Set the thermostat to lowest setting. 3. T urn off all electric power to the fi replace.
12 W415-0298 / K / 12.06.07 This pr ocedure m ust be performed by a qualified service per son! Inspect the pilot for any visible contamination or debris (usually lint, pet hair , spider webs, carpet fi bre, etc.) and remove. Disconnect the pilot from the pilot tubing line.
13 W415-0298 / K / 12.06.07 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Co ntinental® d ealer or distributor. When ordering replacement parts always give the following information: 1.
14 W415-0298 / K / 12.06.07.
15 W415-0298 / K / 12.06.07 Main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engulfi ng the thermo- pile - service or replace Oxygen Depletion Sensor System - correct piping and/or regulator to provide correct pressure Thermopile shorting - clean thermopile connection to the valve.
16 W415-0298 / K / 12.06.07 Flames are consist- ently too large or too small. Carbon- ing occurs. - check pressure readings: Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point.
17 W415-0298 / K / 12.06.07 W olf Steel Fir eplace Ser vice Histor y This fi replace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dea.
18 W415-0298 / K / 12.06.07 NO TES.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Continental Fireplaces CVF36N è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Continental Fireplaces CVF36N - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Continental Fireplaces CVF36N imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Continental Fireplaces CVF36N ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Continental Fireplaces CVF36N, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Continental Fireplaces CVF36N.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Continental Fireplaces CVF36N. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Continental Fireplaces CVF36N insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.