Manuale d’uso / di manutenzione del prodotto CDIZC - P del fabbricante Continental
Vai alla pagina of 16
1 W415-0224 / D / 01.15.04 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Ba rrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .continentalfireplaces.com • ask@continentalfire.
2 W415-0224 / D / 01.15.04 Pg 2 -4 INTRODUCTION Warranty General Instructions General Information Care of Glass & Plated Parts 5 -7 INST ALLA TION Insert V ent Connection Chimney Connection Wall S.
3 W415-0224 / D / 01.15.04 CONTINENTAL gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. CONTINENTAL products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0224 / D / 01.15.04 FOR YOUR SA TISF ACTION, THIS FIREPLACE INSERT HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUALITY! Minimum inlet gas supply pressure is 4.
5 W415-0224 / D / 01.15.04 Pro vide adequate ventila tion air . Provide adequate accessibility clearance for ser vicing and operating the fireplace inser t. Never obstruct the front opening of the fire- place inser t. Objects placed in front of the fireplace must be kept a minimum of 48" away from the front face of the unit.
6 W415-0224 / D / 01.15.04 Move the insert close to its final position inside the wood- burning fireplace. This unit is equipped with 6 levelling screws located as follows: two are on either side of the circulation blower on the rear panel; four are located front and back on either side beneath the log support.
7 W415-0224 / D / 01.15.04 To adjust the trim: If the mitre is out of alignment, open each side and loosen the two screws at either side trim hinge. Slide the trim up or down to adjust and re-tighten screws. There is also a very slight in/out adjustment that can be made.
8 W415-0224 / D / 01.15.04 Positioning the logs improperly will cause flame im- pingement and carboning. PHAZER TM logs and glowing embers, exclusive to Continental Fireplaces, glow when exposed to direct flame and provide a unique and realistic glowing effect that is different in every installation.
9 W415-0224 / D / 01.15.04 The on-off switch is located behind the left side control door . Purge all gas lines with the glass door open. Assure that a continuous gas flow is at the burner before clos- ing the door . Allow several min utes (5-15) for the flame to stabilize after ignition.
10 W415-0224 / D / 01.15.04 1. Turn off the electrical power and the gas supply to the fireplace insert. 2. Remove the fire viewing door. Remove the logs. 3. Detach the two screws from the back of the firebox and remove the panel, as illustrated. 4. Remove the blower access door held on with the re- maining 8 screws.
11 W415-0224 / D / 01.15.04 Remove the pilot screw cap. Adjust the pilot screw to pro- vide properly sized flame. Turn in a clockwise direction to reduce the gas flow .
12 W415-0224 / D / 01.15.04 31* W690-0001 MILLIVOL T THERMOST A T 32* W660-0010 REMOTE CONTROL - ADV ANT AGE 32* W660-001 1 REMOTE CONTROL - ADV ANT AGE PLUS 33* GD660 REMOTE WALL SWITCH C / W 20FT WI.
13 W415-0224 / D / 01.15.04 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
14 W415-0224 / D / 01.15.04 Main burner goes out; pilot stays on. Pilot flame is not large enough or not engulfing the thermopile. Thermopile shorting Remote wall switch wire is too long, too much resistance in the system Faulty thermostat or switch - turn up pilot flame.
15 W415-0224 / D / 01.15.04 Exhaust fumes smelled in room, headaches. - check all seals. Fireplace is spilling. Carbon is being de- posited on glass, logs or combustion chamber surfaces. Flame is impinging on the logs or combustion chamber . - check that the logs are correctly positioned.
16 W415-0224 / D / 01.15.04 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Deale.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Continental CDIZC - P è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Continental CDIZC - P - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Continental CDIZC - P imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Continental CDIZC - P ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Continental CDIZC - P, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Continental CDIZC - P.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Continental CDIZC - P. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Continental CDIZC - P insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.