Turning on or off
To turn the calculator on, press [ ON/C ] ; To turn the calculator off, press [ 2nd ] [ OFF ].
The calculator is powered by two alkaline batteries (G13 or LR44). When the display dims, replace the batteries. Be careful not to be injured when you replace the battery. 1. Unscrew the screws on the back of the calculator. 2. Insert a flat bladed screwdriver into the slot between the upper and lower case then carefully twist it to separate the case. 3. Remove both batteries and dispose of them properly. Never allow children to play with batteries. 4. Wipe off the new batteries with a dry cloth to maintain good contact. 5. Insert the two new batteries with their flat sides (plus terminals) up. 6. Align the upper and lower cases then snap them to close together. 7. Tighten the screws.
This calculator automatically turns it off when not operated for approximately 6~9 minutes. It can be reactivated by pressing [ ON/C ] key and the display, memory, settings are retained.
If the calculator is on but you get unexpected results, press [ MODE ] [ 4 ] ( RESET ) in sequence. A message appears on the display to confirm whether you want to reset the calculator and clear memory contents.
Move the cursor to " Y " by [
], then press [=] to clear all variables, pending operations, statistical data, answers, all previous entries, and memory; To cancel the reset operation without clearing the calculator, please choose " N ".
If the calculator is lock and further key operations becomes impossible, please use a pointed object to press the reset hole to release the condition. It will return all settings to default settings.
Pressing the [ – ] or [ + ] following [ MODE ] key can make the contrast of the screen lighter or darker. Holding either key down will make the display become respectively lighter or darker.

The display comprises two lines and indicators. The upper line is a dot display up to 128 characters. The lower line is capable of displaying a result of up to 12 digits, as well as 2-digits positive or negative exponent.
When formulas are input and executed the calculation by [=], they are displayed on the upper line, and then results are shown on the lower line.
The following indictors appear on the display to indicate you the current status of the calculator.
M Running memory – Result is negative E Error STO Storing variable mode is active RCL Recalling variable mode is active 2nd 2nd set of function keys are active HYP Hyperbolic-trig function will be calculated ENG Engineering symbol notation CPLX Complex number mode is active CONST Display physics constants DEGRAD Angle mode : DEGrees, GRADs, or RADs BIN Binary base OCT Octal base HEX Hexadecimal base ( ) Open parentheses TAB Number of decimal places displayed is fixed STAT Statistics mode is active REG Regression mode is active EDIT Statistics data is being edited CPK CPK : Process capability CP : Precision capability USL Set upper specification limit LSL Setting lower specification limit i Imaginary part
Allow to use undo function
Using " MODE " keys
Press [ MODE ] to display mode menus when specifying an operating mode ( " 1 MAIN ", " 2 STAT ", " 3 CPLX ", " 4 RESET " ) or the engineering symbol notation ( " 5 ENG " ).

1 MAIN : Use this mode for basic calculations, including scientific calculations and Base–n calculations.
2 STAT : Use this mode to perform single–variable and paired–variable statistical calculations and regression calculations.
3 CPLX : Use this mode to perform complex number calculation.
4 RESET : Use this mode to perform reset operation.
5 ENG : Use this mode to allow engineering calculations utilizing engineering symbol.
Give " 2 STAT " as an example :
] until " 2 STAT " is underlined, then enter the desired mode by pressing [=]. Method 2 : Press [ MODE ] and then key in directly the number of
] or [ 2nd ] [
the mode, [ 2 ] , to enter the desired mode immediately.
When you press [ 2nd ], the " 2nd " indicator shown in the display is to tell you that you will be selecting the second function of the next key you press. If you press [ 2nd ] by mistake, simply press [ 2nd ] again to remove the " 2nd " indicator.
If you have made a mistake when entering a number (but you have not yet pressed an arithmetic operator key), just press [ CE ] to clear the last entry then input it again, or delete individual digits by the backspace key [
], or clear all entry by [ ON/C ].
After making corrections, input of the formula is complete, the answer can be obtained by pressing [=]. You can also press [ ON/C ] to clear the immediate results completely (except clearing memory). If you press the wrong arithmetic operation key, just press the correct key to replace it.
The unit offers an undo function which allows you to undo some of the errors you just have made.
When a character which is just deleted by [
], an entry which is just cleared [ CE ], or which is just cleared by [ ON/C ], the "
" indicator shown in the display is to tell you that you can press [ 2nd ] [
] to cancel the operation.
[

This function stores operations that just have been executed. After execution is completed, pressing [
] key will display the operation executed. Pressing [
] or [ 2nd ] [
] will display the operation from the beginning, with the cursor located under the first character. Pressing [ 2nd ] [
] will display the operation from the end, with the cursor located at the space following the last character. You can continue moving the cursor by [
] and editing values or commands for subsequent execution.
] or [ 2nd ] [
The calculator has nine memory variables for repeated use -- A, B, C, D, E, F, M, X, Y. You can store a real number in any of the nine memory variables.
3 0 ÆA 30 [ STO ] [ A ]
¾ (2) Multiple 5 to variable A, then put the result into variable B

You should keep the following rules in mind when using running memory.
M ] key.
M ] or [ 0 ] [ STO ] [ M ] in sequence. ¾ [ ( 3 x 5 ) + ( 56
M ] key to store a value, you can also assign values to memory variable M by [ M+ ]. However, when [ STO ] [ M ] or [ X
M ] is used, previous memory contents stored in variable M are cleared and replaced it with the newly assigned value. When [ M+ ] is used, values is added to present sum in memory.
Each calculation is performed in the following order of precedence:
P )

, x ', y ' .
3 , 10 X , e X, NOT, EXP, DATA in STAT mode.
Output digits : Up to 12 digits.
In general, every reasonable calculation is displayed up to 12 digits mantissa, or 12-digits mantissa plus 2-digits exponent up to 10 ± 99.
Numbers used as input must be within the range of the given function as follow :
,


Error message “ E ” will appear on the display and further calculation becomes impossible when any of the following condition occur.
To release the above errors, please press [ ON/C ].
Use MAIN ( [ MODE ] 1 ( MAIN ) ) mode for basic calculations.
Arithmetic operations are performed by pressing the keys in the same sequence as in the expression.

7 + 5 ¼ 4 = 7 [ + ] 5 [ x ] 4 [=]
For negative values, press [ +/– ] after entering the value; You can enter a number in mantissa and exponent form by [ EXP ] key. ¾ 2.75 x 10 – 5 = 0.0000275
Results greater than 10 12 or less than 10 –11 are displayed in exponential form. ¾ 12369 x 7532 x 74010 = 6895016425080
= 6.89501642508 x 10 12
1 2 3 6 9 ¼ 7 5 3 2 ¼ 7 12369 [ x ] 7532 [ x ] 74010 [=]
Operations inside parentheses are always executed first. SR-281N can use up to 13 levels of consecutive parentheses in a single calculation.
Closed parentheses occurring immediately before operation of the [ ) ] key may be omitted, no matter how many are required. ¾ 2 x { 7 + 6 x ( 5 + 4 ) } = 122
2 ¼ ( 7 + 6 ¼ ( 5 + 4 = 2 [ ( ] 7 [ + ] 6 [ ( ] 5 [ + ] 4 [=]
1 2 2 .
open parenthesis can be omitted. The correct result cannot be derived by entering [ ( ] 2 [ + ] 3 [ ) ] [ EXP ] 2. Be sure to enter [ x ] between the [ ) ] and [ EXP ] in the below example. ¾ ( 2 + 3 ) x 10 2 = 500
( 2 + 3 ) ¼ 1 E 0 2 = [ ( ] 2 [ + ] 3 [ ) ] [ x ] [ EXP ] 2 [=]
5 0 0 .

[ 2nd ] [ % ] divides the number in the display by 100. You can use this key sequence to calculate percentages, add-ons, discounts, and percentage ratios.
1 2 0 ¼ 3 0 % = 120 [ x ] 30 [ 2nd ] [ % ] [=]
55 % = 160
5 5 % = 88 [
] 55 [ 2nd ] [ % ] [=]
1 6 0 .
The calculator has the following display notations for the display value.
To specify the number of decimal places, press [ 2nd ] [ TAB ] and then a value indicating the number of places ( 0~9 ). Values are displayed rounded off to the place specified. To return floating setting, press [ 2nd ] [ TAB ] [ • ].
To change the display mode between floating and scientific notation, press [ F↔E ].
Pressing [ ENG ] or [ 2nd ] [
] will cause the exponent display for the number being displayed to change in multiples of 3. ¾ 6
7 = 0.85714285714…


8 5 7 . 1 4 2 8 5 7 1 4 3 –03
Each time you specify the ENG mode, a displayed result is automatically shown with the corresponding engineering symbol.
pico= 10 – 12, f femto = 10 – 15, a
Perform the following operation to specify engineering symbol notation.
To exit from this mode, press [ MODE ] 5 once again. ¾ 6
8 5 7 . 1 4 2 8 5 7 1 4 3
8 5 7 1 4 2 . 8 5 7 1 4 3

Use MAIN ( [ MODE ] 1 ( MAIN ) ) mode for scientific function calculations.
The calculator can calculate common and natural logarithms and anti-logarithms using [ log ], [ ln ], [ 2nd ] [ 10 x ], and [ 2nd ] [ e x ]. ¾ ln 7 + log 100 = 3.94591014906
l n 7 + l o g 1 0 0 = [ ln ] 7 [ + ] [ log ] 100 [=]
10 ^ 2 + e ^ – 5 = [ 2nd ] [ 10 X ] 2 [ + ] [ 2nd ] [ e X ] 5 [ + / – ] [=]
1 0 0 . 0 0 6 7 3 7 9 4 7
Fraction value display is as follow :
5 56 ∪ 5 」12 Display of 5612
5 」12 Display of 12
the total number of digits of a fractional values ( integer + numerator + denominator + separator marks ) exceeds 12. To enter a mixed number, enter the integer part, press [ a b/c ], enter the numerator, press [ a b/c ], and enter the denominator ; To enter an improper fraction, enter the numerator, press [ a b/c ], and enter the denominator.
7 7 [ a b/c ] 2 [ a b/c ] 3 [ + ] 14 [ a b/c ] 5 [ a b/c ] 7 [=] 2 2
3 + 1 4
During a fraction calculation, if the figure is reducible, a figure is reduced to the lowest terms after pressing a function command key ( [ + ], [ – ], [ x ] or [
d/e ], the displayed value will be converted to the improper fraction and vice versa. To convert between a decimal and fractional result, press [ a b/c ].
] ) or the [=] key. By pressing [ 2nd ] [

¾ 2 9 5 . 4 2 1 4 4 2 4 = = =
4 = 4 [ a b/c ] 2 [ a b/c ] 4 [=]
4 = [ a b/c ]
4 = [ a b/c ] [ 2nd ] [
4 = [ 2nd ] [
Calculations containing both fractions and decimals are calculated in decimal format.
5 + 3 . 7 5 = 8 [ a b/c ] 4 [ a b/c ] 5 [ + ] 3.75 [=]
The calculator enables you to convert an angle unit among degrees(DEG), radians(RAD), and grads(GRAD).
The relation among the three angle units is :
180 ° =πrad = 200 grad
] repeatedly until the unit you want is displayed. ¾ 90 deg. = 1.57079632679 rad. = 100 grad.
DEG [ 2nd ] [ DRG ]
9 0 O = 90 [ 2nd ] [ DRG
d/e ] · d/e ] · ]
![Page 16 of the Citizen SR-281N user manual — ] 3 [=] – 1 . 5](/cdn/reader/3e/3efc569afa889631d2af18538a2d033fc5122936743fbdacae9a8a5029555fdf/images/page-16.webp?w=400)
1 0 0 .
The calculator enables you to convert the sexagesimal figure (degree, minute and second) to decimal notation by pressing [
] or convert the decimal notation to the sexagesimal notation by [ 2nd ] [
].
Sexagesimal figure value display is as follow :
125 45 ׀30 ׀ ׀55 Represent 125 degrees (D), 45 minutes(M), 30.55 seconds(S)
within 12 digits, or the sexagesimal couldn't be shown completely.
DEG 12.755 [ 2nd ] [
] 10.5 [
SR-281N provides standard trigonometric functions and inverse trigonometric functions - sin, cos, tan, sin –1, cos –1 and tan –1.
s i n 3 0 = [ sin ] 30 [=]
3 = 3 [ cos ] [ ( ] 2 [ x ] [ 2nd ] [ π ] [
3 ¼ c o s ( 2 ¼π

3 ¼ s i n –1 0 . 5 = 3 [ 2nd ] [ sin –1 ] 0.5 [=]
SR-281N uses [ 2nd ] [ HYP ] to calculate the hyperbolic functions and inverse-hyperbolic functions - sinh, cosh, tanh, sinh –1, cosh –1 and tanh –1.
c o s h 1 . 5 + 2 = [ 2nd ] [ HYP ] [ cos ] 1.5 [ + ] 2 [=]
s i n h 1 –1 7 = [ 2nd ] [ HYP ] [ 2nd ] [ sin –1 ] 7 [=]
Rectangular Coordinates Polar Coordinates

x + y i = r (cosθ + i sinθ )
angle unit you want. The calculator can perform the conversion between rectangular coordinates and polar coordinates by [ 2nd ] [ P
R ] and [ 2nd ] [ R
P ]. ¾ If x = 5, y = 30, what are r, θ ? Ans : r = 30.4138126515,
θ = 80.537677792 o
P ( 5 , [ 2nd ] [ R
P ] 5 [ 2nd ] [
] 30

3 0 . 4 1 3 8 1 2 6 5 1 5
θ [ 2nd ] [ X↔Y ]
¾ If r = 25, θ = 56 o what are x, y ? Ans : x = 13.9798225868,
y = 20.7259393139
R ( 2 5 , [ 2nd ] [ P
R ] 25 [ 2nd ] [
X [=]
1 3 . 9 7 9 8 2 2 5 8 6 8
Y [ 2nd ] [ X↔Y ]
2 0 . 7 2 5 9 3 9 3 1 3 9
This calculator provides the following probability functions :
[ nPr ] Calculates the number of possible permutations of n item taken r at a time. [ nCr ] Calculates the number of possible combinations of n items taken r at a time. [ x ! ] Calculates the factorial of a specified positive integer n, where n≦69. [ RND ] Generates a random number between 0.000 and 0.999
¾ 840 ! ] ) 4 7 ( [ ! 7 = −
7 P 4 = 7 [ 2nd ] [ nPr ] 4 [=]
8 4 0 .
¾ 5 3 ! ] ) 4 7 ( [ ! 4 ! 7 = −
7 C 4 = 7 [ 2nd ] [ nCr ] 4 [=]
r [=] · ] 56

5 ! = 5 [ 2nd ] [ x ! ] [=]
1 2 0 .
R n d [ 2nd ] [ RND ]
Other functions ( 1/x, , 3 , X , x 2, x 3, x y , INT, FRAC )
The calculator also provides reciprocal ( [ 2nd ] [ 1/x ] ), square root ( [ √ ] ), cubic root ( [ 2nd ] [ 3 ] ), universal root ( [ 2nd ] [ X ] ), square ( [ x 2 ] ), cubic ( [ 2nd ] [ x 3 ] ), and exponentiation ( [ x y ] ) functions.
¾ 139 = 5 + 125 + 21 + 4 + 2 3 3 2
2 2 + √( 4 + 2 1 ) + 2 [ x 2 ] [ + ] [ √ ] [ ( ] 4 [ + ] 21 [ ) ] [ + ] [ 2nd ] [ 3 ] 125 [ + ] 5 [ 2nd ] [ x 3 ] [=] 1 3 9 .
7 x y 5 + 4 X √6 2 5 = 7 [ x y ] 5 [ + ] 4 [ 2nd ] [ X ] 625 [=]
1 6 8 1 2 .
INT Indicate the integer part of a given number
FRAC Indicate the fractional part of a given number ¾ INT ( 10
8 = [ 2nd ] [ INT ] 10 [
¾ FRAC ( 10
8 = [ 2nd ] [ FRAC ] 10 [
0 . 2 5
] 8 [=] · ] 8 [=]

The calculator has a built-in unit conversion feature that enables you to convert numbers among different units.
] can convert the number to another unit. ¾ 1 y d 2 = 9 f t 2 = 0.00000083612 km 2
] or [ 2nd ] [
f t 2 y d 2 m 2 1 [ CONV ] [ CONV ] [
f t 2 y d 2 m 2 [ 2nd ] [
k m 2 h e c t a r e s [
You can use 136 physics constants in your calculations. With the following constants :
Data is referred to Peter J.Mohr and Barry N.Taylor, CODATA Recommended Values of the Fundamental Physical Constants:1998, Journal of Physical and Chemical Reference Data,Vol.28, No.6,1999 and Reviews of Modern Physics,Vol.72, No.2, 2000.
No. Quantity Symbol Value, Unit 1. Speed of light in vacuum c 299792458 m s –1


μe/μB –1.00115965219
μe/μN –1838.28196604

μ'p/μB 1.52099313216 x10 –3

μn/μB –1.0418756325 x10 –3
μd/μB 0.46697545565 x10 –3
μd/μN 0.85743822849
μ'h/μB –1.15867147414 x10 –3
μ'h/μN –2.12749771825

To insert a constant at the cursor position :
] until the constant you want is underlined. 3. Press [=].
] or [ 2nd ] [
You also can use the [ CONST ] key in combination with a number, 1 through 136, to recall a physical constants. For example, press 15 [ CONST ].
h h N A l p t p 3 [ x ] [ CONST ] [ CONST ] [
3 ¼ N A = [=] [=]
Use MAIN ( [ MODE ] 1 ( MAIN ) ) mode for Base–n calculations.
The unit enables you to calculate in number base other than decimal. The calculator can add, subtract, multiply, and divide binary, octal, and hexadecimal numbers.
The following shows the numerals that can be used in each number base.
Hexadecimal base ( h ) : 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, A, B, C, D, E, F

To distinguish the A, B, C, D, E and F used in the hexadecimal base from standard letters, they appear as shown in the below.
Display (Lower) Key Display
D ID
B IB
E IE
F IF
Select the number base you want to use with [
BIN ], [
HEX ]. The " BIN ", " b ", " OCT ", " o ", " HEX ", " h " indicators show you which number base you are using. If none of the indictors appears in the display, you are in decimal base.
Bases conversions ¾ 37 (base 8) = 31 (base 10) = 1F (base 16)
DEG OCT [ 2nd ] [
0 3 7 o
DEG [ 2nd ] [
DEG HEX [ 2nd ] [
0 1 F h
For a result in binary base, it will be displayed using block function. The maximum of 32 digits are displayed in 4 blocks of 8 digits.
Indicates Block 1 presently displayed Indicates Block 2 presently displayed Indicates Block 3 presently displayed Indicates Block 4 presently displayed
110 10 011 b
The block function comprises upper and lower block indicators. The upper indicator means current block position, and the lower indicator means total blocks for a result.

In the binary base, the block 1 is displayed immediately after calculation. Other blocks ( block 2 ~ block 4 ) are displayed by pressing [
].
For example, input 47577557 16 Press [ 2nd ] [
Indicates Block 1 presently displayed
[ 2nd ] [
Indicates Block 2 presently displayed
Indicates Block 3 presently displayed
Indicates Block 4 presently displayed
47577557 16 = Block 4 + Block 3 + Block 2 + Block 1 = 01000111010101110111010101010111 2
1001 2 = 1170 8
b 1 [ 2nd ] [
HEX ] 1E F [ + ] [ 2nd ] [
DEG OCT h 1 IE IF + 1 2 3 4
BIN ] 1001 [=] [ 2nd ] [
] [ 2nd ] [
OCT ] 0 1 1 7 0 o
In binary, octal, and hexadecimal bases, the calculator represents negative numbers using complement notation.
The complement is the result of subtracting that number from 100000000000000000000000000000000 in that number's base by pressing [ NEG ] key in non-decimal bases.

DEG HEX N E G h 3 /A [ 2nd ] [
F F F F F F C 6
Logical operation
Logical operations are performed through logical products (AND), negative logical (NAND), logical sums (OR), exclusive logical sums (XOR), negation (NOT), and negation of exclusive logical sums (XNOR). ¾ 1010 2 AND ( /A 16 OR 7 16 ) = 12 8
BIN ] 1010 [ AND ] [ ( ] [ 2nd ] [
DEG OCT b 1 0 1 0 A N D ( h [ 2nd ] [
HEX ] A [ OR ] 7 [ ) ] [=]
OCT ] 0 1 2 o
[ 2nd ] [
Use STAT ( [ MODE ] 2 ( STAT ) ) mode for statistical calculations.
The calculators can perform both single–variable statistical calculations and paired–variable in this mode.
Press [ MODE ] 2 ( STAT ) to enter STAT mode. There are six items in STAT mode, asking you to select one of them,
STAT
DEG EXP PWR D–CL
STAT
Single–variable statistics
Paired-variable / Regression statistics
D–CL Clear all statistical data
Always make sure you clear statistical data by D–CL before performing statistical calculations.
(A) To input single–variable data using the following syntaxes :

# Multiple data of the same value :
[ DATA ] < x value > [ x ] < Number of repeats >
(B) To input paired–variable / regression data using the following
syntaxes :
] < y value >
# Multiple data of the same value :
[ DATA ] < x value > [
] < y value > [ x ] < Number of repeats >
clear all data by selecting D-CL mode.
The values of the statistical variables depend on the data you input. You can recall them by the key operations shown in the below table.
n ( [ n ] ) Number of the x values entered
x ( [2nd]+[ x ] ) Mean of the x values
Sx ( [2nd]+[ Sx ] ) Sample standard deviation of x values
σx ( [2nd]+[ σ
x ] ) Population standard deviation of x values
∑x ( [2nd]+[ ∑
x ] ) Sum of all x values
2 ( [2nd]+[ ∑
x 2 ]) Sum of all x 2 values
CP ( [2nd]+[ CP ] ) Potential capability precision of the x values
Minimum (CPU, CPL) of the x values, where
CPU is upper spec. limit of capability
precision and CPL is lower spec. limit of
CPK = Min ( CPU , CPL ) = CP ( 1 – Ca )
n ( [ n ] ) Number of x-y pairs entered
x ( [2nd]+[ x ] )
Mean of the x values or y values
y ( [2nd]+[ y ] )

Sx ( [2nd]+[ Sx ] )
Sample standard deviation of x values or y
Sy ( [2nd]+[ Sy ] )
σx ( [2nd]+[ σ
Population standard deviation of x values or
σy ( [2nd]+[ σ
∑x ( [2nd]+[ ∑
Sum of all x values or y values
∑y ( [2nd]+[ ∑
∑x 2 ( [2nd]+[ ∑
Sum of all x 2 values or y2 values
∑y 2 ( [2nd]+[ ∑
∑x y Sum of ( x • y ) for all x-y pairs
CP ( [2nd]+[ CP ] ) Potential capability precision of the x values
Minimum (CPU, CPL) of the x values, where
CPU is upper spec. limit of capability
precision and CPL is lower spec. limit of
CPK = Min ( CPU , CPL ) = CP ( 1 – Ca )
a ( [2nd]+[ a ] ) Regression formula constant term a
b ( [2nd]+[ b ] ) Regression formula regression coefficient b
r ( [2nd]+[ r ] ) Correlation coefficient r
x ’ ([ x ’ ] ) Estimated value of x
y ’ ([ y ’ ] ) Estimated value of y
You also can add a new data anytime. The unit automatically recalculates statistics each time you press [ DATA ] and enter a new data value. ¾ Enter data : USL = 95, LSL = 70, DATA 1 = 75, DATA 2 = 85, DATA
3 = 90, DATA 4 = 82, DATA 5 = 77, then find out n = 5,
= 81.8, Sx = 6.05805249234, σx = 5.41848687366, CP = 0.76897236513, and CPK = 0.72590991268
D A T A 5 [=] [ DATA ] 75 [ DATA ] 85 [ DATA ] 90 [ DATA ] 82 [ DATA ] 77


σ x [ 2nd ] [ σ x ]
U S L = [ 2nd ] [ CP ] 95
¾ Find a, b and r for the following data using linear regression and
estimate x = ? for y =573 and y = ? for x = 19.

D A T A 4 = 2 8 , [=] [ DATA ] 15 [
DEG STAT
] 525 [ DATA ] 28 [
] 475 [ DATA ] 21 [
REG
] 678 6 7 8
DEG STAT a [ 2nd ] [ a ]
1 7 6 . 1 0 6 3 2 9 1 1 4
DEG STAT b [ 2nd ] [ b ]
1 7 . 5 8 7 3 4 1 7 7 2 2
DEG STAT r [ 2nd ] [ r ]
x ’ 5 7 3 573 [ x ’ ]
REG
2 2 . 5 6 7 0 0 7 3 4 1 3
y ’ 1 9 19 [ y ’ ]
REG
5 1 0 . 2 6 5 8 2 2 7 8 5
The method to delete data depends on whether you have already stored the data by next pressing [ DATA ] key or not.
To delete data you just input but have not yet stored it by next pressing [ DATA ] , simple press [ CE ].
To delete data that you have already stored by next pressing [ DATA ] ,
(A) To delete single–variable data using the following syntaxes :
# < x value > [ 2nd ] [ DEL ]
# < x value > [ x ] < Number of repeats > [ 2nd ] [ DEL ]
(B) To delete paired–variable / regression data using the following
syntaxes:
] < y value > [ 2nd ] [ DEL ]
# Multiple data-set with the same value :
< x value > [
] < y value > [ x ] < Number of repeats > [ 2nd ] [ DEL ]
If you enter and delete a value that isn't included in the stored data by mistake, " dEL Error " appears, but the previous data are still retained.
Press [ 2nd ] [ EDIT ] to enter EDIT mode. The EDIT mode is convenient and friendly for you to view, correct, delete data.

(A) In 1–VAR mode, the method to view data depends on whether you
want to view data item or not.
# Each time you press [ DATA ], first data item appears 1 second
and then the corresponding value.
STAT
[ DATA ]
EDIT
# Each time you press [=], value appears directly on the display
without data item.
EDIT
(B) In REG mode, each time you press [ DATA ], data item and x value
appear on the screen at the same time. You can press [
] to switch between x and y value.
STAT
DEG DATA 1 = 15 , 45
STAT
[ DATA ]
EDIT [
EDIT
If you want to correct data, find out and enter a new entry to replace it.
A “ FULL” is indicated when any of the following conditions occur and further data entry becomes impossible. Just pressing any key can clear the indicator. The previous data entries are still retained unless you exit STAT mode.
Use CPLX ( [ MODE ] 3 ( CPLX ) ) mode for complex calculations.
Complex mode enables you to add, subtract, multiply, and divide complex numbers.
The results of a complex operation are displayed as follow :
Re Real value Im Imaginary value
ab Absolute value ar Argument value

¾ ( 7 – 9 i ) + ( 15 + 12 i ) = 22 + 3 i , ab = 22.2036033112, ar =
7.76516601843
CPLX DEG
R e I m a b a r 7 [ – ] 9 [ i ] [ + ] 15 [ + ] 12 [ i ] [=]
R e I m a b a r [
R e I m a b a r [
2 2 . 2 0 3 6 0 3 3 1 1 2
R e I m a b a r [
] · ] · ]


I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.
Invia la prima domanda: risponderanno altri possessori o il nostro team.