Manuale d’uso / di manutenzione del prodotto 67119 del fabbricante Chicago Electric
Vai alla pagina of 20
1-1/2 HP PLUNGE ROUTER 671 19 SET UP AND OPERA TING INSTRUCTIONS Distributed exclusively by Harbor Freight T ools ® . 3491 Mission Oaks Blvd., Camarillo, CA 9301 1 Visit our website at: http://www .harborfreight.com Read this material before using this product.
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 2 CONTENTS IMPORT ANT SAFETY INFORMA TION ............................ 3 GENERAL POWER T OOL SAFETY W ARNINGS....................... 3 PLUNGE ROUTER SAFETY W ARNINGS ................
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 3 SA VE THIS MANUAL Keep this manual for the safety warn- ings and precautions, assembly , operat- ing, inspection, maintenance and cleaning procedures.
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 4 Unmodied plugs and matching out - lets will reduce risk of electric shock. A void body contact with grounded b. surfaces such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is grounded.
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 5 Power tool use and care 4. Do not force the power tool. Use a. the correct power tool for your application. The correct power tool will do the job better and safer at the rate for which it was designed.
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 6 Keep hands away from the cutting 8. area. Do not place hands beneath the workpiece for any reason. Keep the base of the router in rm contact with the workpiece while cutting. Keep Handles dry , clean, and free of 9.
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 7 • Do not use with power switch locked on. • Properly maintain and inspect to avoid electrical shock. • Any power cord must be properly grounded. Ground Fault Circuit Inter- rupter (GFCI) should also be imple- mented – it prevents sustained elec- trical shock.
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 8 Grip tool as lightly as possible (while 6. still keeping safe control of it). Let the tool do the work. T o reduce vibration, maintain the tool 7. as explained in this manual. If any abnormal vibration occurs, stop use immediately .
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 9 Double Insulated T ools: T ools with T wo Prong Plugs Outlets for 2-Prong Plug T ools marked “Double Insulated” do 1.
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 10 RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS* (120/240 VOL T) NAMEPLA TE AMPERES (at full load) EXTENSION CORD LENGTH 25’ 50’ 75’ 100’ 150’ 0 – 2.0 18 18 18 18 16 2.
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 1 1 SPECIFICA TIONS Power 1-1/2 HP Electrical Input 120 V~ / 60 Hz / 10 A Motor Speed 1 1,000 - 28,000 RPM (No Load) Collet Capacit.
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 12 OPERA TING INSTRUCTIONS Read the ENTIRE IMPORT ANT SAFETY INFORMA TION section at the beginning of this manual including all text under subheadings therein before set up or use of this product.
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 13 Loosen the Thumb Screw so that the 1. Depth Stop Bar (30) can slide freely . Rotate the Adjusting Knob (26) until 2. the Depth Adjusting Bolt (29) pro - trudes about 1/4” from the Depth Stop Bar .
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 14 Slide the bars on the Edge Guide b. into the slots on the Base of the Router with the fence facing the workpiece. Note: The Edge Guide can be inserted into either side of the tool to make cuts along the left or right side of the material.
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 15 tool may try to twist from the strong initial torque. Note: The Router bit should always be fed into the stock from left to right so as to match the clockwise rotation of the router .
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 16 MAINTENANCE AND SER VICING Procedures not specically explained in this manual must be performed only by a qualied technician.
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 17 T roubleshooting Problem Possible Causes Likely Solutions T ool will not start. Cord not connected. 1. No power at outlet. 2. T ool’ s thermal reset breaker 3. tripped (if equipped).
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 18 Part Description Qty 1 T apping Screw 8 2 Cover 1 3 Screw 2 4 Speed Adjuster 1 5 T apping Screw 5 6 T apping Screw 2 7 Cover 1 8.
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 19 ASSEMBL Y DIAGRAM Record Product’ s Serial Number Here: Note: If product has no serial number , record month and year of purchase instead. Note: Some parts are listed and shown for illustration purposes only , and are not avail- able individually as replacement parts.
SKU 671 19 For technical questions, please call 1-800-444-3353. Page 20 LIMITED 90 DA Y W ARRANTY Harbor Freight T ools Co. makes every ef fort to assure that its products meet high quality and durabi.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Chicago Electric 67119 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Chicago Electric 67119 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Chicago Electric 67119 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Chicago Electric 67119 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Chicago Electric 67119, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Chicago Electric 67119.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Chicago Electric 67119. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Chicago Electric 67119 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.