User M anual.
P ag e 2 of 26 S cor pion ™ GV C /RV M/RG Y Us er M anu al ( R ev. 0 2k ) T ABLE O F C ON TEN TS 1. Be fore you Begin ............................................................................ 3 W hat i s Incl uded ................................
Sc orpi on ™ G VC /R V M/RG Y Us er M anu al (R ev. 0 2k ) P ag e 3 of 26 1. B EFORE YOU B EGIN Wha t is I nc l ude d • 1 x Scorpion ™ GVC, RVM, or RGY • 1 x Powe r Cord • 1 x W ar r a n t y.
P ag e 4 of 26 Sc orpi on ™ G VC / RV M/R G Y Us er Manu al (R ev. 02k ) Pr odu ct at a Gla nc e Use on Dimm er Auto Prog rams O ut d o or U s e Auto - rang i ng Power Sup ply Sound .
Sc orpi on ™ G VC /R V M/RG Y Us er M anu al (R ev. 0 2k ) P ag e 5 of 26 Safe t y Not es (C ont. ) • Avoid direct ey e con tact w it h laser ligh t.
P ag e 6 of 26 Sc orpi on ™ G VC / RV M/R G Y Us er Manu al (R ev. 02k ) Laser Sa fet y Notes STO P AND READ ALL THE LASER SAFETY NO TES BELOW La s er Li ght i s di f f er en t f r om any ot her li ght s o ur c e s wi th wh i ch you may be fa miliar.
Sc orpi on ™ G VC /R V M/RG Y Us er M anu al (R ev. 0 2k ) P ag e 7 of 26 Laser Sa fet y Label s NOTICE Scor pion ™ GVC sticker shown Th e st i c ker on your unit will re flec t the ac tual Scorpion ™ fixtur e mode l, whether GVC, RGY, or RVM.
P ag e 8 of 26 Sc orpi on ™ G VC / RV M/R G Y Us er Manu al (R ev. 02k ) Laser Em is si on Dat a Laser light - Avoid direct ey e contac t! Further guide l ines and safety progra ms for safe use of lasers can be f ound in t he ANSI Z136.1 S t an dard “For Safe Use of Lase rs” , ava il a bl e from the Lase r Ins titute of Am er i c a: w w w.
Sc orpi on ™ G VC /R V M/RG Y Us er M anu al (R ev. 0 2k ) P ag e 9 of 26 2. I NTRO DUCTION Pr oduct O ver view Contr ol Pa nel (LED display) DMX Out DMX In Power S witch Fuse holder Power In Power .
P ag e 10 of 26 S cor pi on™ GV C /RV M/RG Y Us er M anu al (R ev. 0 2k ) Pr odu ct Dim e nsi o ns.
Sc orpi on ™ G VC /R V M/RG Y Us er M anu al (R ev. 0 2k ) P ag e 11 of 26 3. S ETUP AC P o w e r This produc t has an auto - ran gi ng p owe r supply and it c an w ork with an input voltage range of 100~240 VAC, 50/60 Hz .
P ag e 12 of 26 S cor pi on™ GV C /RV M/RG Y Us er M anu al (R ev. 0 2k ) M ounti ng Orientation Th e Scorpion™ GVC/RVM /RGY uni t s may be mounted in any posit ion, provide d t h er e i s a d eq u a t e r oom f o r v en t i l at i o n. Riggi ng Be sure t hat t he st ructure onto which you are m ounting this product can support its we ight .
Sc orpi on ™ G VC /R V M/RG Y Us er M anu al (R ev. 0 2k ) P ag e 13 of 26 Pr oper Usage Th i s fi xt ur e is for overhe ad mounting on l y . Fo r saf ety purpose s, CHAUVET ® reco mm ends mounting your lighting e ff ect fixtures on stea dy elevate d pl a tf or ms or sturdy overhe ad supports using suitable hanging cla mps.
P ag e 14 of 26 S cor pi on™ GV C /RV M/RG Y Us er M anu al (R ev. 0 2k ) 4. O PERA TION Contr ol Pan el Oper at ion To access the cont rol pane l functions, use the four buttons located unde rneath the display.
Sc orpi on ™ G VC /R V M/RG Y Us er M anu al (R ev. 0 2k ) P ag e 15 of 26 M enu Op ti on s The m enu below refers to thr e e differen t CM Y produc ts, G VC, RV M , and RGY, each w ith a different se t of colors .
P ag e 16 of 26 S cor pi on™ GV C /RV M/RG Y Us er M anu al (R ev. 0 2k ) Con fi gur a ti on DMX Mode Se tt ing this product to ope rat e in DM X mode will allow you to con tr ol it with a DMX controller. 1) Conne c t this produ ct to a su i table powe r out l et.
Sc orpi on ™ G VC /R V M/RG Y Us er M anu al (R ev. 0 2k ) P ag e 17 of 26 Aut omati c Mode To e nabl e the Auto matic mode , follow the inst ructions be low: 1) Press <M EN U > re peate dl y until the ac tive opt ion o f the Aut o/Sound b ranch ( AF1 to r dM ) shows blink i ng on the d is play.
P ag e 18 of 26 S cor pi on™ GV C /RV M/RG Y Us er M anu al (R ev. 0 2k ) Master/Sl ave Mode This mode al lows a single S corpion™ GVC/RVM /RGY f i xture (the “master ”) to control the actions o f one or mo re Scorpion ™ GVC/RVM /RGY u nits (the “slaves” ) without the need of a DM X contr oller.
Sc orpi on ™ G VC /R V M/RG Y Us er M anu al (R ev. 0 2k ) P ag e 19 of 26 DMX Chan nel Assi gnments a nd Values Chan nel Fun ctio n Valu e Setting 1 Control M ode (U se ch an n el s 2~ 10 in thi s .
P ag e 20 of 26 S cor pi on™ GV C /RV M/RG Y Us er M anu al (R ev. 0 2k ) DMX Ch.2 P atter n Selection DM X V ALUE P ATTE RN DM X V ALUE P ATTE RN DM X V ALUE P ATTE RN 000~ 00 7 096~ 10 3 19 0~ 19 .
Sc orpi on ™ G VC /R V M/RG Y Us er M anu al (R ev. 0 2k ) P ag e 21 of 26 5. T ECHNICAL I N FORMA TION Fix tur e Mai nte na nce Dust build up reduce s li gh t output pe rf or m ance and can cau se ove rheating. Th i s can lead t o r eduction of the li ght source’s life and m ec h ani c al wea r .
P ag e 22 of 26 S cor pi on™ GV C /RV M/RG Y Us er M anu al (R ev. 0 2k ) Ge nera l T roub les hoot ing Symptom Pos sib le C au se P os sib le Acti on Circ uit br eak er or f us e k eeps blow in g .
Sc orpi on ™ G VC /R V M/RG Y Us er M anu al (R ev. 0 2k ) P ag e 23 of 26 Ret ur ns Pr oc ed ure The user m ust send the merchandise prepaid, in t he original box , and wit h its original packing a nd acce ssories. C HAUVET ® w il l not issue call t ags.
P ag e 24 of 26 S cor pi on™ GV C /RV M/RG Y Us er M anu al (R ev. 0 2k ) DMX Primer The U SI TT DMX512 - A data tr ans mission protoco l (DMX , from now on) i s based on the EIA - 48 5 s tandard and i t h as 512 chan nels (001 to 512) .
Sc orpi on ™ G VC /R V M/RG Y Us er M anu al (R ev. 0 2k ) P ag e 25 of 26 DMX Cab l ing The DMX protocol require s usi ng special data cab les to acco mm odate for the high spee d di gital signa ls i t uses.
P ag e 26 of 26 S cor pi on™ GV C /RV M/RG Y Us er M anu al (R ev. 0 2k ) 6. T ECHNICAL S PECIFICAT IONS Dimensio n s and Weight Length Widt h Heig ht Weight 11 in (276 m m) 8.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Chauvet RVM è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Chauvet RVM - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Chauvet RVM imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Chauvet RVM ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Chauvet RVM, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Chauvet RVM.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Chauvet RVM. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Chauvet RVM insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.