GENERAL INFORMATION This gas room heater should be installed by a qualified installer in accordance with local building codes and with current National Fuel Gas Code. ANSI Z223.1 . This heater should not be installed in a confined space unless provisions are made for adequate combustion and ventilation air.
PYROMASTER@ UVHB26 Vent-Free Heaters UVHB26 Series Gas Appliance ) MANTEL FPS1212 FP21214 BRASS TRIM (TOP) BRASS TRIM (BOTTOM) HEARTH BASE 3/4" MOUNTING TABS HEARTH BASE TOP VIEW FP729 Fig. 1. UVHB26 Series specifications. .~~:) UVHB26 Series Gas Appliance ~I§§§I~ ~ 26.
PYROMASTER@ UVHB26 Vent-Free Heaters DESCRIPTION The UVHB vent-free heaters is designed to be installed into a FPS1212 or FPS1214 mantel cabinet only. It may not be installed in any other manner. The UVHB26 is available in Natural or Propane gas, equipped with an oxygen depletion sensor with a standing pilot.
PYROMASTER@ UVHB26 Vent-Free Heaters INSTAllATION 0 1. PREPARING THE UVHB26 To be sure that each step of the heater installation is in order, use the check-off boxes provided. The UVHB26 may only be used with the approved mantel and hearth assembly. 1.
PYROMASTER@ UVHB26 Vent-Free Heaters 0 3.RUN GAS LINE FROM ITS SOURCE TO THE HEATER If gas piping from the source to the heater loca- tion has not been accomplished, install the required pipe. Consult local plumbing code to assure proper pipe size. The gas pipeline can be brought in through the right side of the heater.
PYROMASTER@ UVHB26 Vent-Free Heaters 0 4. OPTIONAL FK24 FAN HOOK-UP NOTE: The FK24 fan should be installed before the mantel cabinet is complete. Later installation will be more difficult. 1. Remove the two (2) screws holding the screen rods inside the bay top.
PYROMASTER@ UVHB26 Vent-Free Heaters A WHEN INSTALLED, THE HEATER MUST BEELECTRICALL Y CON- NECTED AND GROUNDED IN AC- CORDANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES: U.S. INSTALLATIONS: FOLLOW LOCAL CODES AND THE NATIONAL ELECTRICAL CODE, ANSI/NFPA NO.
PYROMASTER@ UVHB26 Vent-Free Heaters D 10. lOG INSTAllATION (refer to fig. 9) 1. Set the back log on the studs attached to the burner pan. 2. Install the front log in-between the ember guard and front lip of the unit. This should be a snug fit. 3. Set the "Y"log in the notches in the front and rear logs.
PYROMASTER@ UVHB26 Vent-Free Heaters OPERATING INSTRUCTIONS FIRST FIRING Upon completing the gas line connection, a small amount of air will be trapped in the line. When first lighting the unit with pilot light, it will take a few minutes to purge the trapped air.
PYROl'1ASTER@ UVHB26 Vent-Free Heaters 6. Turn knob on gas control counterclockwise ~ to PilOT. 7. Push in control knob all the way and immedi- ately light pilot depressing the piezo igniter button at least once every second until a flame appears.
PYROMASTER@ UVHB26 Vent-Free Heaters MAINTENANCE Keep the control compartment, logs and burner area surrounding the logs clean by vacuuming or brushing at least twice a year. THE LOGS CAN GET VERY HOT - HANDLE ONLY WHEN COOL. Always turn off gas to the pilot before cleaning.
PYROMASTER@ UVHB26 Vent-Free Heaters The air shutter is set at factory no adjustment should be necessary. FLAME ADJUSTMENT For units equipped with Hilla valves, flame adjust- ment is accomplished by rotating the Hilla adjust- ment knob located near the center of the gas control.
PYROMASTER@ UVHB26 Vent-free Heaters TKOUBLESUOOTING. Uoneywell VS8421 START -NO CHECK . SUPPLY LINE HOOKED UP . SHUTOFF VALVE OPEN YES ~ . LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN. .FORSPARKATELECTRODE WHILE DEPRESSING PIElO 1/8" GAP TO PILOT HOOD NEEDED.
PYROMASTER@ UVtfB26 Vent-Free Heaters ACCESSORIES The following accessories for these heaters are available from your local Pyromaster distributor. Each accessory comes with a separate installation instruction for mounting to the particular heater. Be sure to read each instruction thoroughly before installing.
'h~ .1 ."", j .,,/ PYROMASTER@ UVHB26 Vent-Free Heaters UVUB26 REPLACEMENT PARTS 7 ~I~~~I~ ,.. , " ...,.. ...". .,.". , '" ,...".. "",'" ". S ~ II """.. ".".
PYROMASTER@ UVHB26 Vent-Free Heaters REPLACEMENT PARTS - UVC SERIES 18 .) "" ) .",,) ,,) Description PART NO. 1. Log - Assembly 3187169 1a. Log - Back 3187164 1 b. Log - Front 3187165 1 c. Log - Left 3187166 1d. Log - Right 3187167 1e. Log - "Y" 3187168 2a.
CFM Corporation 2695 Meadowv ale Boulevard Mississauga , Ontario L5N 8A3 Canada (800) 668-5323 www .cfmcor p .com.
13 PYROMASTER ® UVHB10 Vent-Free Heaters 20004232 LIMITED 2/20 YEAR W ARRANTY For CFM Harris Systems Decorative Gas Appliances The CFM Harris Systems extends the warranties specified in paragraphs A .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il CFM UVHB26 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del CFM UVHB26 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso CFM UVHB26 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul CFM UVHB26 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il CFM UVHB26, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del CFM UVHB26.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il CFM UVHB26. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo CFM UVHB26 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.