58PHA/PHX Performan ce Boost 80 4 --- W a y M u l t i p o i s e Induced - - - Combus tion Gas Fur nace Inpu t Cap ac iti e s: 45,000 thru 135,000 Bt uh Installation, Start - - - up, Ope rating and Service and Maintenance Instructions Ser ies 100/A SAFETY CONSIDERA TIONS 2 .
2 2-7/16" 1-1/8" 28-7/8" (733mm) 25-1/4" 22-9/16" JUNCTION BOX LOCA TION 7/8" DI A ACCESSORY 1/2" (13 mm) DIA. THERMOST A T WIRE ENTRY 3-15/16" (84mm) LEFT HAND GAS ENTRY 33-5/16" 24-7/8" 5-1/2" 7/8" (22mm) DIA.
3 ins t ruc t ions thor oughl y and f ol low a ll wa r nings or c auti ons inclu d e in literature and attached to th e u n it. Co n sult local buil di ng code s, the c ur re nt edit i ons of the Na tiona l Fuel Ga s Code (NFG C) NFP A 54/ANSI Z223. 1 and the Nat ional Electrical C o d e (NE C) N F P A 7 0 .
4 A08471 Fig. 2 - - Cle ar ance s t o Combus ti ble s CODES AND ST ANDARDS Fo llo w all n atio nal an d lo cal co d es and stan dard s in add itio n to the s e i nstr uc ti ons . The ins t al la tion mus t com ply wi t h re gul at i ons of the s ervi ng gas suppl ie r, l oc al buil di ng, hea t ing, plumbi ng, a nd othe r c odes .
5 Min 60ºF / 16ºC Max 85ºF/ 29ºC A02055 Fig . 3 - - Return A ir T em p eratu re Gener al Installat ion S US : C urren t ed itio n of th e N FG C and the N F P A 90 B . Fo r co p ies, con tact th e N ation al F ire P rotectio n Asso ciatio n In c., B atterym arch P ark , Qu in cy, MA 02269; (ww w .
6 THE BLOWER IS LOCA TED T O THE RIGHT OF THE BURNER SECTION, AND AIR CONDITIONED AIR IS DISCHARGED T O THE LEFT . THE BLOWER IS LOCA TED BELOW THE BURNER SECTION, AND CONDITIONED AIR IS DISCHARGED UPW ARD .
7 S Ma sonr y aci d wa s hing ma ter i al s All f uel- - burni ng equipm ent m ust be suppl i ed wit h air f or fue l com bust i on. Suf fi c ie nt air m ust be pr ovide d to avoid ne gati ve pressu re in the equ ip m ent ro o m o r sp ace.
8 T abl e 3 – Mi ni mum Space vol ume s for 100% c ombust i on, V en ti lat ion, and Dil ut ion fr om Indoors ACH* OTHER THAN FAN - - - ASSISTED TOT AL (1, 000’S BTUH GAS IN PUT RATE FAN - - - AS SISTE D TOTAL (1, 000’S BTUH GAS IN PUT RA TE) 30 40 50 44 66 88 110 132 S p a c eV o l u m e( f t .
9 a. One openi ng MUS T com men ce with in 1 2 - - in . (3 0 0 mm ) of the ceiling an d th e secon d o p enin g MUS T commenc e with in 1 2 - - in . (3 0 0 m m) o f th e floo r .
10 of at least 2 in . 2 /1,000 Bt uh (4, 400 mm 2 /kW) of total input r a ti ng of al l gas a pplia nc es . 2. A n attic or crawlsp ace may b e co n sidered a sp ace that fr e el y communi ca tes wi t.
11 1 3 / 4 ″ 1 3 / 4 ″ 1 3/ 4 ″ 1 3/ 4 ″ 5/ 16 ″ 5 / 16 ″ 5/ 16 ″ 5/ 16 ″ (44mm) (8mm) (44mm) (8mm) (8mm) (8mm) (44mm) (44mm) A89014 Fig. 10 - - Le ve li ng Legs 4. Adjust out s ide nut to pr ovide de s ir e d hei ght , and t ight e n ins i de nut to se c ure a r ra nge me nt.
12 APPROVED COIL ASSEMBLY OR COIL BOX FURNACE SHEET METAL PLENUM FLOOR OPENING COMBUSTIBLE FLOORING A08556 Fig. 13 - - Fur nac e, Pl e num, and Coil As se mbl y or Coil Box Ins tal l ed on a Combus ti.
13 T able 4 – Openi ng Di mens i ons - - In. (mm) FURNACE CASIN G WIDTH APPLICATION PLENUM O PEN IN G FLOOR OPENING A B C D 14–3/16 (360) Upflow Ap plication s on Co mbu stible or Non combu stible.
14 3. Re move bottom cl os ure pa ne l. 4. R ein stall bo tto m filler p an el an d screws. S ide Retu rn A ir Inlet Side Re tur n Air Inlet Th ese fu rn aces are ship p ed w ith b o tto m closu re p an el in stalled i n bott om re tur n - - air openi ng.
15 UPFLO W DO WNFLOW HORIZONT AL YES NO NO YES YES YES NO 120 ° MIN YES 120 ° MIN YES 120 ° MIN 90 ° 90 ° A02020 Fig. 14 - - Duct Fl anges 1 / 4 " (6mm) THREADED ROD 4 REQ.
16 M ETHOD 2 USE (4) # 8 x 3 / 4 ( 19 mm) SHEET M ET AL S C REWS F OR EA C H STRAP . THE STRAPS SHOULD BE VERTI C AL AGAINST THE F URNA C E SIDES AND NOT PULL A WA Y F RO M THE F URNA C E SIDES.
17 Ret urn Air Conne ct ions FIRE HAZARD Fai l ure t o foll ow thi s wa rni ng could c ause pe rsona l injur y , dea th and/ or prope rt y da mage . Nev er con n ect retu rn - - air d u cts to the b ack o f the furn ace.
18 T a ble 5 – Air D elivery - - CF M (With Filter)* UNI T SIZE RETURN - - - AIR SUPPL Y SPEED EXT ER NAL STATIC PRE S SUR E (In. wc) 0.1 0.2 0.3 0.4 0.
19 A02075 Fig. 18 - - Upflow Ret ur n Air Conf igur ati ons and Res t ri c ti ons A02163 Fig. 19 - - Downfl ow Ret urn Air Configur ati ons and Res t ri c ti ons 58PHA.
20 A02162 Fig. 20 - - Horiz ontal Re t urn Ai r Confi gur ati ons and Re str ic tions 2” (51mm) Street Elbow A08551 Fig. 21 - - Burne r and Manif old 58PHA.
21 T a bl e 7 – Electrical Da ta FURNACE MODEL V O L T S --- H E R T Z --- PHASE OPER ATING VOL TAGE* (VOL T S) MAX UNI T (AMPS) UNI T AMP ACITY# (AMPS) MAX WIRE LENGTH } FT . ( M ) MAX FUSE/ CKT B KR { (AMPS) MIN WIRE GAGE MAX MIN 045 - - - 08 / 024045 1 1 5 --- 6 0 --- 1 127 104 8.
22 FURNACE MA Y NOT OPERA TE Failu re to follo w this cautio n may resu lt in interm ittent furn ace o p eration . Furna ce cont r ol must be gr ounde d for prope r opera t ion or el s e c ontr ol wi ll l oc k out. Contr ol mus t r ema in grounded thr ough gr ee n/yel low wir e r out ed t o ga s va lve and ma nifol d brack et screw.
23 A03221 Fig. 23 - - Fiel d- - Supplie d El ec t ri c al Box on Fur nac e Cas i ng POWER CORD INST ALLA TION IN FURNACE J- -B O X NOTE : P o wer cord s mu st b e ab le to han d le th e electrical re qui re me nts l ist ed in T a ble 7. Re f er t o power c ord ma nufa c tur e r’ s li s ti ngs.
24 BLOWER O FF -DELA Y 2 4-V THER M OST A T TER M INALS 3-A M P F USE LED OPERA TION & DIAGNOSTI C LIGHT BLOWER SPEED SELE C TION TER M INALS HEA T F AN C OOL SP ARE 2 SP ARE 1 11 5 -V A C (L 2 ) NEUTRAL C ONNE C TIONS 11 5 -V A C (L 1 ) NEUTRAL C ONNE C TIONS EA C - 1 TER M INAL ( 11 5 -V A C 1 .
25 CARBON MONOXIDE POI SONING HAZARD Failu re to follo w th e step s ou tlin ed below fo r each app lian ce conn ected to the v en tin g system bein g pl aced into oper ati on c ould re sul t in ca rbon m onoxide poi s oning or death .
26 See notes 2,5,7, and 10 on the page following these figures . A04215 Fig. 26 - - Singl e- - Stage Fur nac e wit h Singl e- - Spee d Air Con- dit ione r See notes 2,5,8, and 10 on the page following these figures .
27 HUMIDFIER (24V AC) See notes 1, 2, 4, 11, 12, and 13 on the page following these figures . A04219 Fig. 30 - - Dual Fue l Ther mos t at wit h Singl e- - Stage Fur nac e and Singl e- -Speed H eat Pump HUMIDFIER (24V AC) See notes 1, 2, 3, 4, 11, 12, and 14 on the page following these figures .
28 Canada (and U. S.A. )- - Th is furn ace is p erm itted to be ven ted in to a clay tile- - lined m ason ry ch imn ey th at is e xpos ed to the outdoor s bel ow the r oof li ne , provi ded: 1. V e nt conne ctor i s T ype- - B double- - wall , and 2. T h is fu rnace is com mo n vented w ith at least 1 d raft hoodequi ppe d appli ance , and 3.
29 CHIMNEY INSPECTION CHART F or additional requirements ref er to the National Fuel Gas Code NFP A 54/ANSI Z223.1 and ANSI/NFP A 211 Chimneys , Fireplaces, V ents, and Solid Fuel Burning Appliances in the U .S.A. or to the Canadian installation Code CSA-B149.
30 T o pr eve nt conde ns at i on in t he f urna c e a nd vent s ys te m, the follo w ing p recau tion s m ust b e o bserv ed : 1. T h e retu rn - - air tem p erature m u st b e at least 60 _ F (16 _ .
31 SEE NO TES: 1,2,4,7,8,9 on the page follo wing these figures A03208 Fig. 34 - - Upfl ow Appli c ati on- - V ent E lbow Up SEE NO TES: 1,2,3,4,7,8,9 on the pages follo wing these figures A03209 Fig. 35 - - Upfl ow Appli c ati on- - V ent E lbow Ri ght SEE NO TES:1,2,3,4,5,7,8,9 on the page follo wing these figures A03210 Fig.
32 SEE NO TES: 1 , 2 ,4, 5 , 6 ,7, 8 , 9 o n the p a ge follo w in g these f i gures A03207 Fig. 38 - - Downfl ow Appli cat ion- - V e nt Elbow Lef t then Up SEE NO TES:1,2,3,4,5,7,8,9 on the page follo wing these figures.
33 SEE NO TES: 1,2,4,7,8,9 on the page follo wing these figures A03214 Fig. 42 - - Hori zontal Ri ght Appl ic at ion- - V ent El bow Right SEE NO TES: 1,2,4,5,7,8,9 on the page follo wing these figures A03215 Fig. 43 - - Hori z ontal Le f t Appli cat ion - - V ent E lbow Up SEE NO TES: 1,2,4,5,7,8,9 on the page follo wing these figures A03219 Fig.
34 V e nti ng Note s for Fi gur es 34- - 46 1. For common vent , vent conne c tor s i zi ng and vent material: U nited States - - - - use the N F GC Canad a - - - - use the CAN/CSA- - B149.
35 A04128 Fig. 48 - - Rounded End of K nockout A04129 Fig. 49 - - Knoc kout Pull ed Loos e A04130 Fig. 50 - - Hamme r and Scr ewdr ive r Us e d for K nockout A04131 Fig.
36 ST ART- - UP , ADJUSTMENT , AND SAFETY CHECK Gener al FIRE HAZARD Fai l ure to f oll ow this wa rni ng c ould r e sul t in pe r sona l inj ur y , dea t h and/ or prope rt y da ma ge. Th is fu rnace is eq u ip p ed w ith m anu al reset limit sw itches in the ga s c ontr ol a re a .
37 The input r a ti ng for a ltitudes a bove 2,000 ft. ( 610 M ) must be redu ced b y 4 p ercen t for each 1 ,0 00 ft. (30 5 M) a bove se a leve l. For ins t al l at i ons bel ow 2000 ft . ( 610 M) , re fer to the uni t ra ting pla te . For inst a ll a ti ons a bove 2000 ft.
38 c. M easu re tim e (in sec) fo r g as meter to com p lete 1 re voluti on and note re a ding. The 2 or 5 cubi c fe et di a l pro v id es a mo re accu rate m easurem en t o f gas flo w. d. Re fer t o T abl e 12 for cubi c ft. of ga s pe r hr . e. Mu ltiply g as rate (cu ft.
39 T able 1 1 – Speed Se lec ti on COL OR SPEED AS SHIPPED Gray 5 COOL Y ellow 4 SPARE Blue 3 HEA T Orange 2 SP AR E Red 1* CONT F AN * C o n t i n u o u s --- b l o w e r s p e e d --- a s s h i p p e d d e f a u l t FURNACE OVERHEA TING HAZARD Failu re to follo w this cautio n m ay result in reduced furn ace life.
40 T a ble 1 2 – G a s Ra te (Cu F t./Hr .) SECONDS FOR 1 REVOL UTION SIZE OF TE ST DIAL SECONDS FOR 1 REVOL UTION SIZE OF TE ST DIAL 1 Cu Ft . 2C uF t .
41 T able 13 – Orif ic e Size * and Mani f old Pr e ss ur e (In. wc ) f or Gas Input Rat e A08220 58PHA.
42 T able 13 - - Orif ic e Size * and Manif old Pr ess ur e (In. wc ) for G as Input Rat e (CON T) A08220A 58PHA.
43 SER VICE AND MAINTENANCE PROCEDURES FIRE, I NJURY , OR DEA TH HAZARD Fai l ure to f oll ow this wa rni ng c ould r e sul t in pe r sona l inj ur y , dea t h and/ or prope rt y da ma ge. Th e ability to pro p erly perfo rm main ten ance on th is equi pme nt r equi r es ce rta i n knowledge , mec hani c al s k ills, tool s , a nd e quipme nt.
44 T able 14 – Orif ic e Size * And Mani fol d Pr es sur e ( In. wc ) For Gas Input Rat e A08221 58PHA.
45 T able 14- - Ori fi c e Siz e* And Manifol d Pr es sur e ( In. wc ) For Gas Input Rat e (C ONT) A08221A To ini t ia te the compo n e n t test seque n ce, shut O FF the room thermost a t or d i sc o nn ect the "R" thermost a t le a d. B r i efly sh ort the TEST / TWIN term ina l to the " C om 2 4V" te rm ina l.
46 CARE AND MAINTENANCE FIRE OR EXPLOSI ON HAZARD Fai l ure to f oll ow this wa rni ng c ould r e sul t in pe r sona l inj ur y , dea t h and/ or prope rt y da ma ge. Ne ver s tor e anythi ng on, near , or in c onta c t wit h the furn ace, su ch as: 1.
47 NOTE : The blowe r whe el s houl d not be dropped or be nt as bal a nce w il l be af fe cte d. The f oll owi ng ste ps s hould be per f orme d by a q u alified serv ice ag en cy. T o en su re long life an d h ig h efficiency, clean accu mu lated d irt and gre ase f rom blowe r whe el a nd motor a nnua ll y .
48 the m t hor oughly . A he a vy buil d- - up of soot a nd ca rbon i ndi ca t es that a p ro bl em ex ists wh ich n eed s to be co rrected , such as im prope r a djus t ment of ma nif old pres sure ,.
49 hydroc a rbons or i nadequa t e sea l may oc c ur) a nd R TV se al a nt (G. E. 162, 6702, or Dow - - Corni ng 738) ar e nee ded bef ore starting in stallatio n. DO NOT su b stitute an y oth er ty p e o f RTV se ala nt. G.E. 162 (P771- - 9003) i s a va il a ble thr ough RCD in 3 - - oz.
50 2. Cooli ng Mode The the r mos ta t “ ca l ls f or cool i ng.” a. Singl e- - Spee d Cooling (Se e Fig. 25 - - 32 for the rmost at conne c ti ons ) The the r mos ta t c los e s the R- - to- - G - - and- - Y ci r cui t s.
51 5. He at pump (Se e Fig. 25 - - 32 for the rm ost a t connec tions .) W hen ins t al l ed wit h a hea t pump, the fur nac e contr ol aut oma t ic a ll y c hange s the ti mi ng se quence to avoi d l ong blo w er o ff times du rin g d em and d efro st cycles.
52 A08176 Fig. 59 - - Wi ri ng Diagr am 58PHA.
53 Is LED st a tus l i ght o n ? Is LED st a tus l i ght bl in k in g r a p i dly w i thout a p a use? Is LED st a tus l i ght bl in k in g ON / O FF slow ly w i th a comb ina t i o n of shor t an d lo n g fl a shes? Determ in e st a tus code.
54 11 NO PREVIOUS C ODE – Stored codes a re er a sed a fter 7 2 hours. O n RED LED bo a rds stored st a tus codes c an a lso be er a sed whe n e ver power ( 115 V or 2 4V ) i s in terrupted. Ru n system through a he a t in g or cool in g cycle to chec k system.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Carrier 58PHA/PHX è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Carrier 58PHA/PHX - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Carrier 58PHA/PHX imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Carrier 58PHA/PHX ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Carrier 58PHA/PHX, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Carrier 58PHA/PHX.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Carrier 58PHA/PHX. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Carrier 58PHA/PHX insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.