Manuale d’uso / di manutenzione del prodotto 50VL---A del fabbricante Carrier
Vai alla pagina of 30
1 50VL - - - A Pe r fo rm a n c e t 14 SEER Sin gle - - - P ac kage d Ai r Condi tion er Syste m wit h Puron ® (R - - - 410A) Re frige rant Sing le and Thre e Phase 2 --- 5 N o m i n a l T o n s ( S i z e s 2 4 --- 6 0 ) Installation Instructions NOTE : Read the en tire instru ction m anual b efore starting th e installatio n.
2 ELECTRICAL SHOCK HAZARD Fai lur e t o fol low thi s w ar ning c ould r es ult i n per sona l inj ury or dea th. Befo re installin g or serv icing sy stem, alway s tu rn o f f main powe r t o sys te m and ins ta ll loc kout t ag. Ther e ma y be mo re th an on e d iscon nect switch .
3 A09462 Fig. 2 - - 50VL- - A24- - 36 Unit Di me nsi ons 50VL - - A.
4 A09463 Fig. 3 - - 50VL- - A42- - 60 Unit Di me nsi ons 50VL - - A.
5 RETURN AIR SMALL BASE UNIT SUPPL Y AIR LARGE BASE UNIT UNIT PLACEMENT ON COMMON CURB L ARGE CURB SMALL OR LARGE BASE UNIT SMALL/COMMON CURB ROOF CURB DET AIL Wood nailer* Roofcurb* Insulation (field.
6 A CCESS P ANELS MUST BE IN PLA CE WHEN RIGGING. P ANNEA UX D'A CCES DOIT ÊTRE EN PLA CE POUR MANIPULA TION. 50CY502286 2.0 CA UTION - NOTICE TO RIGGERS PRUDENCE - AVIS AUX MANIPULATEUR Use top skid as spreader bar.
7 Step 3 — Provid e Clearan ces Th e req uired min imu m serv ice clearances are sh own in F ig. 2 and 3. Ad equ ate v entilatio n and ou t door a ir mus t be provide d. The outdoor fa n dra ws a ir t hrough t he outdoor coi l a nd dis cha r ge s it thr ough the top f an gr ille.
8 Ste p 6 — Conne ct C onde nsate Dra in NOTE : Wh en installin g c onde ns at e dra in conne ct ion be s ure t o com ply with lo cal codes and restrictio ns. Mode l 50VL- -A dispos es of c ondens ate wate r thr ough a 3/4 i n. NP T fittin g wh ich exits thr ough t he ba s e on the e vapor at or c oil access side.
9 Horizontal Duct Covers A09076 Basepan Downflow (V ertical) Supply Knockout Basepan Downflow (V ertical) Return Knockout A09093 Fig. 9 - - Suppl y and Retur n Duct Ope ning Step 8 — In stal l Electri cal Con necti ons ELECTRICAL SHOCK HAZARD Fai lur e t o fol low thi s w ar ning c ould r es ult i n per sona l inj ury or dea th.
10 POWER SUPPL Y FIELD-SUPPLIED FUSED DISCONNECT HIGH V OLT AGE POWER LEADS (SEE UNIT WIRING LABEL ) EQUIP GR CONTROL BO X LOW-V OL T AG E POWER LEADS (SEE UNIT WIRING LABEL) W1 Y G R C WHT(W1) YEL(Y).
11 T able 1 – Phys ic al Dat a- - Unit 50VL - - A UNIT S IZE 24 30 36 42 48 60 NOMI NAL C AP A CI TY (to n) 2 2 --- 1 / 2 3 3 --- 1 / 2 4 5 SHI PPING WEIG HT* lb . SHI PPING WEIG HT* ( kg) 295 134 307 139 365 166 421 191 439 199 467 212 COMP RESSORS Quan tity Scroll 1 RE FRIG ERA NT ( R - - - 410A) Quan tity lb Quan tity (kg) 6.
12 PRE- -ST AR T - -UP ENVIRONMENT AL, FIRE, EXPLOSI ON, ELECTRICAL SHOCK HAZARD Fai lur e t o fol low thi s w ar ning c ould r es ult i n per sona l inj ury or dea th a nd/or proper ty da ma ge. 1. Fol low r e cogni ze d sa fe ty pra ct ic e s a nd wea r pr ote ct ive goggle s w hen c hec king or s er vic ing r ef r ige ra nt s yst em .
13 Pro ceed as fo llow s: 1. R emov e caps fro m lo w- - an d hig h - - p ressure serv ice fitting s. 2. U sing ho ses with valv e core dep ressors, attach low - - and high- -pres sur e ga uge hose s to l ow- - and hi gh - - pre ss ure service fittin gs, resp ectively.
14 HIGH LOW COM QC5 QC4 QC3 KZ KL 07 09 08 0L0 ALO R13 C8 R11 Q1 Q3 D2 AL2 DCR QCR QC1 C RL 01 G1 G2 Z1 A7 R9 AB A15 C4 C9 C0 QIL Z2 06 04 U1 C3 R4 RL4 JWZ C7 D5 D3 R3 R5 R6 R2 JW5 QCB Y R W 2 Y C W 3W 3W 2 W 2C JW4 P2 JW3 P4 P1 W2 W3 Y2 Y1 Y DH GC R SSTZ -8 P3 SDL 24VAC/R 3AMP CDM/C F1 STD DEHUM A09059 Fig.
15 T able 4 – Dr y Coil Ai r De li ver y* - - Hori zont al Dis char ge - - Unit 50VL - - A24- - 60 UNIT MOT OR SPEED WIRE C OL OR EXTER NAL STA TIC PRES SUR E (IN.
16 T able 6 – 50VL- - A Hori z ontal and Downfl ow Disc har ge W et Coil Pr es sur e Dr op (I N. W .C. ) UNIT SIZE STANDARD C FM (SC FM) 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 24 0.030 0.037 0.044 0.053 0.063 ------ --- --- 30 - - - 0.
17 A11004 Fig. 12 - - Connec ti on Wi ri ng Diagr am 208/230- - 1- - 60 50VL - - A.
18 A11003 Fig. 12 Cont. - - Ladder W ir ing Di agram 208/230- - 1- - 60 50VL - - A.
19 A11010 Fig. 13 - - Connec ti on Wi ri ng Diagr am 208/230- - 3- - 60 50VL - - A.
20 A11009 Fig. 13 Cont. - - Ladder W ir ing Di agram 208/230- - 3- - 60 50VL - - A.
21 DEHUM STD BLK 7 7 6 6 11 11 10 10 8 8 2 2 3 3 4 4 1 1 5 5 9 9 12 12 BLU YEL ECON PLUG YEL BLK ENERGIZED LEGEND FIELD SPLICE TERMINAL (MARKED) TERMINAL (UNMARKED) SPLICE (IF USED) SPLICE (MARKED) FA.
22 STD DEHUM BLK D LADDER WIRING DIAGRAM YEL 21 L1 CCH 13 COMP 460V C R S CAP 24V 23 T3 T1 T2 460V 24V BLK YEL YEL BLK YEL YEL RED L3 BLK BLK G/Y BRN BLU 13 GRN 11 BLK C,TRAN 11 11 IFM OFM IFM X N G L.
23 A09089 Fig. 15 - - Cooli ng Chargi ng Char t 50VL - - A.
24 MAINTENANCE T o ensur e c ontinui ng high pe rf orm anc e, and to mini mi ze the po ssibility of p rematu re equip men t failure, p eriod ic main tenan ce mus t be per forme d on this equipme nt. Thi s c ooli ng unit should be insp ected at least on ce each y ear b y a qu alified service perso n.
25 MOTOR F AN GRILLE MOTOR SHAFT A A08505 MAX DIST ANCE BETWEEN TOP OF F AN GRILLE AND BOTT OM OF F AN BLADE SIZE “A” IN. MM 24 6.3 160 30 6.3 160 36 7.3 185 42 7.6 193 48 7.6 193 60 7.6 193 Fig. 16 - - Fan Blade Posi ti on Compressor Access Panel Blower Access Panel Control Access Panel A09214 Fig .
26 each electrical co m ponent wit h t he prope r el ec tr ic al ins tr ume nta ti on. Re fe r t o the unit w ir ing la bel whe n ma king t hes e che ckouts .
27 readily. POE o ils can abso rb 15 tim es as much w ater as oth er oils des igne d for HCFC a nd CFC re fr iger ant s. T ake a ll nec es sa ry precau tion s to avo id e xpos ure of t he oil to the a tm osphe re .
28 T able 10 – T r ouble shoot ing Char t SYMPTOM CAUSE REMEDY Comp ressor and ou tdoo r fan will no t start Power f ailure Call power c ompany Fuse blown or c ircuit break er tripped Replace fus e .
29 AIR CO NDITI ONER WI TH PURON (R- -410A) QUICK RE FERENCE GUID E Pu ron refrig erant op erates at 50 - - 70 p ercent h igh er pressu res than R - - 2 2. B e sure that serv icing equ ipm ent an d rep lacement co m ponent s ar e des igne d to oper at e wit h Puron.
30 ST AR T - - UP CHECKLIST (Re move and St or e i n Job Fil es ) I. PRELI MINAR Y INFORMA TION MODEL NO.: SERIAL NO. : DA TE: TECHNICI AN: II. PRE ST A RT - - UP (In sert check m ark in b ox a s ea c.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Carrier 50VL---A è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Carrier 50VL---A - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Carrier 50VL---A imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Carrier 50VL---A ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Carrier 50VL---A, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Carrier 50VL---A.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Carrier 50VL---A. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Carrier 50VL---A insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.