42VMC Console T h e S t a n d a r d s I n s t i t u t i o n o f I s r a e l Q u a l i t y A s s u r e d F i r m SI ISO 9001 INST ALLA TION MANU AL.
42VMC Split system “Console night & da y” indoor unit GB - 1 ENGLISH The operation and maintenance instructions for the indoor unit and the installation instructions for the indoor and the outdoor unit are given in the manuals for each unit. These are supplied with the unit.
42VMC GB - 2 Dimensions and weights - Minim um c learances (mm) 50 min 500 min 50 min Dimensions and weights Minimum c learances W all installation Ceiling installation Model 42VMC009 42VMC012 42VMC01.
42VMC GB - 3 ENGLISH Note: Height difference / Connection length / Pipe bends: See outdoor unit installation manual. Connections 햲 Outdoor unit 햳 Indoor unit 햴 Height difference T able III: Operating limits Cooling / Heating Ref er to outdoor unit installation manual.
42VMC GB - 4 Unit installation Read this instruction manual thoroughly before starting the installation. • This unit complies with low-v oltag e (EEC/73/23) and electro- magnetic compatibility (EEC/89/336) directives. • The installation must be carried out by a qualified installer .
42VMC GB - 5 ENGLISH ...any obstruction of the unit air outlet or return. ...exposure to oil vapours. ...installation in areas with high frequency waves. ... any rise in the condensate drain piping. . ...horizontal condensate drain piping with less than 2% slope .
42VMC GB - 6 Installation D C B A Hole Plate T emplate V ertical wall-mounting • The pref erred arrangement is generally under a window sill on an external wall. This mak es it easier to install the interconnecting tubing, electrical connections and condensate pipework to the outdoor unit.
42VMC GB - 7 ENGLISH For horizontal installation T o allow the condensate drain pipe to correctly come out of the unit, proceed as follo ws: • Remov e from suction grille, the par t of grille fixed tonguing, pressing it until tabs is unhooked. Mount condensate drain pipe cov er 햷 supplied, fitting it as necessary .
42VMC GB - 8 Refrigerant connections Connection to the unit Insufficient tightening torque will cause gas leaks. Overtightening the fittings will damage the tube flaring and cause gas leaks. T ubing diameter T orque mm (inches) Nm 6.35 (1/4 ” )1 8 9.
42VMC GB - 9 ENGLISH Electrical connections Jumper positioning: Units are equipped with a jumper inside the electric control box, to make them suitab le for the two installation typologies: W all vertical installation: jumper inserted. Ceiling horizontal installation: jumper removed.
42VMC GB - 10 Electrical connections Cooling onl y Unit System Unit System 햳 햲 10 100 10 120 T erminal bo x legend Ear th. L Live po wer supply . N Neutral power supply . N Neutral connection indoor/outdoor unit. R Live connection indoor/outdoor unit.
42VMC GB - 11 ENGLISH Heat pump Unit System Unit System 햳 햲 10 100 10 120 햲 Mains supply connecting cable (field wiring). 햳 Connecting cable, indoor-outdoor units (field wiring). 쐃 Indoor unit 쐇 Outdoor unit 쐋 Main switch 쐏 Time-delay fuse or circuit break er (see outdoor unit installation manual) T erminal bo x legend Ear th.
42VMC GB - 12 System configuration System configuration Units are f actor y configured as heat pumps. When a cooling only system is installed, it is necessar y to change the f actor y configuration.
42VMC GB - 13 ENGLISH Operating test • P erform the operating test after the units hav e been installed in position and the gas leak test has been completed. • Check all electrical connections (instructions and wir ing diagram). • Inser t the batteries into the remote control and leave it OFF .
42VMC GB - 14 Air delivery and fresh air renewal Ceiling installation, cooling Ceiling installation, heating Fresh air renewal Units are prearranged f or introduction of renewal air through a prepunched hole located on back side . Back knoc kout allows connection of fresh air inlet duct.
L010125H33 - 0402 Via R. Sanzio, 9 - 20058 Villasanta (MI) Italy - T el. 039/3636.1 The manufacturer reserves the right to change any product specifications without notice.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Carrier 42VMC è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Carrier 42VMC - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Carrier 42VMC imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Carrier 42VMC ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Carrier 42VMC, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Carrier 42VMC.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Carrier 42VMC. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Carrier 42VMC insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.