EXAR Corporation, 48720 Kato Road, Fremont, CA 94538 • (510) 668-7000 • FAX (510) 668-7017 July 1998-2 XRD9829REF USER MANU AL CIS 30-BIT COLOR SINGLE LINE SCANNER.
XRD9829REF 2 Rev. 1.00 EVALUATION KIT PART LIST This kit contains the following: • XRD9829REF CIS 30-Bit Color Single Line Scanner • XRD9829REF User Manual • ScanIt 1.
XRD9829REF 3 Rev. 1.00 FLIP- FLOP CANON CWB-30216G 300DPI COLOR CIS XRD9829 FLIP- FLOP FIFO SRAM FIFO SRAM INTEL 486 Compatible PARALLEL PORT DB25 CONNECTOR CIS CONTROL SIGNALS DATA DATA DATA DATA DATA 5-BIT BUS NIBBLE XRD9829 CONTROL SIGNALS PARALLEL PORT CONTROL DC 1.
XRD9829REF 4 Rev. 1.00 OPERATIONAL PROCEDURE The routine listed below will first calibrate the photo response of the CIS using the XRD9829. After calibration, the XRD9829REF can be used to scan any color target to show CIS non-color corrected response.
XRD9829REF 5 Rev. 1.00 Parallel Port Configurations 9. Confirm the parallel port address as follows: a. Select the Start Menu, choose Settings, then choose Control Panel b. From the Control Panel window which pops up, double-click on System c . In the System Properties window, select Device Manager d.
XRD9829REF 6 Rev. 1.00 S 1 S 0 D 5 D 4 D 7 D 6 D 1 D 0 D 3 D 2 1 0 Figure 3. Dip Switches Set to Value 1100010000 to Reset the XRD9829.
XRD9829REF 7 Rev. 1.00 Control Registers Function D 7 D 6 D 5 D 4 D 3 D 2 D 1 D 0 Power-up (Register State S1/S0) (Note 1) Gain (00) G 5 G 4 G 3 G 2 G 1 G 0 X X 000000XX (MSB) (LSB) Offset O 7 O 6 O 5.
XRD9829REF 8 Rev. 1.00 12 . Select the Start Menu, choose Programs, then choose XRD9829REF icon 13 . A window will pop up as shown below. The upper window shows the Plot of Captured Data and the lower window shows the Histogram of data. Figure 3 shows the pop- up window when ScanIt is first s t a r t e d .
XRD9829REF 9 Rev. 1.00 15. Pick the black target out from the kit and put it on a flat area. Place the XRD9829REF on top of the black target with the CIS sensor facing downwards. From the CAPTURE menu select SNAP SHOT for a single line scan of the black target with the dip switches set to zero.
XRD9829REF 10 Rev. 1.00 Figure 6. Black Target Scan After Global Offset Adjust.
XRD9829REF 11 Rev. 1.00 RL VRT VRB VDD VIN0 - VIN2 XRD9829 C I S VIN0 VIN3 5V 100K 34K Figure 7. Simplified Block Diagram Showing Global Offset Adjustment by XRD9829 Using External Resistor Ladder 17. Set the dip switches to 0111000000 to select the internal offset DAC for fine offset adjustment.
XRD9829REF 12 Rev. 1.00 Figure 8. Black Target Scan After Global and Fine Adjust.
XRD9829REF 13 Rev. 1.00 RL VRT VRB VDD VIN0 XRD9829 C I S 8-Bit Offset DAC Figure 9. Simplified Block Diagram Showing Fine Offset Adjustment by XRD9829 18. Switch the black target to the enclosed white target. From the CAPTURE menu select SNAP SHOT for a single line scan of the white target.
XRD9829REF 14 Rev. 1.00 Figure 10. White Target Scan Without Gain Adjustment 19. Set the dip switches to 0000000100 to select the desired gain. Push the Serial Port button. From the CAPTURE menu select SNAP SHOT. The gain should move the output of the CIS to almost full scale.
XRD9829REF 15 Rev. 1.00 Figure 11. White Target Scan After Gain Adjustment.
XRD9829REF 16 Rev. 1.00 VIN0 XRD9829 C I S RL VRT VRB VDD PGA 6-Bit Gain Register Figure 12. Simplied Block Diagram Showing Gain Adjustment by XRD9829 20.
XRD9829REF 17 Rev. 1.00 Figure 13. Gray-scale Target Scan Important: 1. If at any time an unexpected result is shown or the demo system seems to not working, please pull the AC adapter out from the wall outlet to cycle power. Start the procedures again from Step 11.
XRD9829REF 18 Rev. 1.00 Schematics for XRD9829REF Page 1 of 3..
XRD9829REF 19 Rev. 1.00 Schematics for XRD9829REF Page 2 of 3..
XRD9829REF 20 Rev. 1.00 Schematics for XRD9829REF Page 3 of 3..
XRD9829REF 21 Rev. 1.00 Notes.
XRD9829REF 22 Rev. 1.00 Notes.
XRD9829REF 23 Rev. 1.00 Notes.
XRD9829REF 24 Rev. 1.00 NOTICE EXAR Corporation reserves the right to make changes to the products contained in this publication in order to improve design, performance or reliability.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Canon XRD9829REF è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Canon XRD9829REF - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Canon XRD9829REF imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Canon XRD9829REF ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Canon XRD9829REF, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Canon XRD9829REF.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Canon XRD9829REF. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Canon XRD9829REF insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.