SM4M / SM16M Storage Module User Guide .
.
Guarantee • • • Campbell Sci entific Ltd, Campbell Park, 80 Hathern Road, Shepshed, Leices tershire, LE12 9RP UK Tel: +44 (0) 1509 601141 Fax: +44 (0) 1509 601091 Email: support@c ampbellsc i.
.
i Contents Section 1. SM4M/S M16M Stor age Module Overview ..................................................................1-1 1.1 Specifications ........................................................................................ 1-1 1.2 Physical Description .
SM4M/SM16M Storage Module User G uide ii Section 4. Storage Modul e Memory: Details of Data Storag e ...........................................4-1 4.1 File Marks ........................................................................................
1-1 Section 1. SM4M / SM16M Storage Module Overview 1.1 Specifications ° ° ° °.
SM4M/SM16M Storage Module User G uide 1-2 µ Logan, UT SM4M SN: S O L I D S T A T E S T O R A G E M O D U L E MADE IN USA STA TUS W R ITE Figure 1-1 Storage Module and SC12 Cable 1.
Section 1. SM4M/SM16M Storage Module Ov erview 1-3 1.3 Power 1.3.1 Primary Power 1.3.2 Backup Power and Data Retention 1.4 Function 1.4.1 Operati on with Curr ent Datal ogger s Dat alo gge r SM4M/ 16M.
SM4M/SM16M Storage Module User G uide 1-4 1.4.2 Operati on wi th Dataloggers wi th Ol der Operating Systems (Printer-Enabl e Method) 21X CR7X CR7 CR21 DSP4 SM4M / 16M Figure 1-3 Pin-Enable O perations 1.
Section 1. SM4M/SM16M Storage Module Ov erview 1-5 1.4.4 Memory Configuration 1.4.5 Baud Rates 1.4.6 File Marks The SM must be disc onnected from power for a minimum of 10 seconds to be certain it places a File Mark in the SM when reconnected.
SM4M/SM16M Storage Module User G uide 1-6 1.5 Quick Start-Up Procedure 1.5.1 Preparation 1.5.2 Progr ammi ng the Datalogger to Send Data to the SM.
Section 1. SM4M/SM16M Storage Module Ov erview 1-7 1.5.3 Manual Dump 1.5.4 Data Retrieval.
.
2-1 Section 2. Storing Data from Current Dataloggers 2.1 Instruction 96 — Output Data Under Program Control.
SM4M/SM16M Storage Module User G uide 2-2 Be sure to complete the data transfer before making any changes in the datalogger program. Changing a program and then compiling it will advance the datalogger ’s Stor age Module Pointer to the position of the DSP.
Section 2. Storing Data from Cur rent Dataloggers 2-3 2.1.2 Use of Two Storage Modul es with the 21X or CR7 2.2 *8 and *9 Mode — Keyboard-Initiated Data Transfer 2.
SM4M/SM16M Storage Module User G uide 2-4 2.3.1 Burst Data wi th CR10/10X, CR23X Datalogger s 2.3.2 Burst Data wi th 21X Datal oggers.
3-1 Section 3. The Printer Enable Method of Data Storage If the PE line is high when power is applied, the SM will not store data until the next time PE goes high. Also, if power to the SM is interrupted dur ing transmis sion, data stored since the last time PE went high will be lost.
SM4M/SM16M Storage Module User G uide 3-2 3.2.2 *4 Mode — Output Device Enable While the module will work with *4, data is stored in the module in ASCII format which requir es up to 5 times more memory spac e than binary format.
4-1 Section 4. Storage Module Memory: Details of Data Storage 4.1 File Marks The SM must be disconnected from power for a minimum of 10 seconds to be certain it places a File Mark in the SM when reconnected.
SM4M/SM16M Storage Module User G uide 4-2 4.3 Data Formats – Space Requirements 4.4 Available Storage.
Section 4. Storage Module Memory : Details of Data Storage 4-3 4.5 Bad Data • •.
.
5-1 Section 5. Data Retrieval 5.1 Hardware Logan, UT SM4M SN: SOLID STATE STORAGE MODULE MADE IN USA SC532 9 PIN PERIPHERAL TO RS232 INTERFACE MADE IN USA PERIPHERAL RS232 9227 Figure 5-1 Storage Module Connec ted to a Portable PC via an SC532 Interface 5.
SM4M/SM16M Storage Module User G uide 5-2 PC SM4M/16M Data- logge r Figure 5-2 Communication Via the CR500/510, CR10/10X or CR23X SM4M/16M CR23X PC RS232 CS I/O 9-Pin Cable SC12 9-Pin Cable Figure 5-3 Communication Via the CR23X 5.
Section 5. Data Retrieval 5-3 5.2 Datalogger Support Software 5.2.1 SMS 5.3 Data Retrieval Steps 5.3.1 Windows/ NT PCs 5.3.2 CR500/510, CR10/10X and CR23X Telecommunications Interface.
.
6-1 Section 6. Storing and Retrieving Datalogger Programs 6.1 SMS Storage Module Support Software 6.2 *D Mode — With Datalogger.
SM4M/SM16M Storage Module User G uide 6-2 6.3 Using DSP4 Heads Up Display to Store and Retrieve Datalogger Programs NOTE.
A-1 Appendix A. *9 Mode – Storage Module Commands.
SM4M/SM16M Storage Module User G uide A-2.
B-1 Appendix B. Telecommunications Commands A Status NOTE.
SM4M/SM16M Storage Module User G uide B-2 AA Advanced Stat us nnnnB nnnnC Comma Delineated ASCII Dump nnnnF Binary Dump nnnnnnG Go To Location nnnnnn OD Go To th e Oldest Data 01G Go To Last File 08G .
Appendix B. Telecommunic ations Commands B-3 4H Move Dump Point er To Display Location Pointer 9H Store File Mark in Data nl Dump Program n (n = 1…8) nJ Store Pr ogram n (n = 1…8) nJJ Store Pr ogr.
SM4M/SM16M Storage Module User G uide B-4 1249K Quick Reset abfeL Switch Set tings M or * Disconnect N OS Signatur e.
C-1 Appendix C. Storage Module 9-Pin Connector ± µ µ.
.
D-1 Appendix D. Upgrading the Operating System Collect any data stor ed in the module before upgrading the operating system, as any data held in memory is irreversibl y erased during the upgrade pr ocess .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Campbell SM4M è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Campbell SM4M - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Campbell SM4M imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Campbell SM4M ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Campbell SM4M, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Campbell SM4M.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Campbell SM4M. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Campbell SM4M insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.