MONO CLASS D AMPLIFIERS.
INTRODUCTION 2 Thank you for purchasing a Cadence T ype RS amplifier . Over the past years, the technology used to create audio amplifiers has grown by leaps and bounds. W e have thousands of satisfied customers still using our first generation Ultra Drive amplifiers which are almost 10 years old.
FEA TURES 3 GOLD PLA TED TERMINALS: BASS DRIVE EQUALIZA TION CIRCUITRY : “ADR”: - ACTIVE DYNAMIC REGULA TION CLASS D AUDIO ST AGE PERFORMANCE POWER AND PROTECTION CIRCUITR Y : STIFFENING CAP ACITO.
FEA TURES 4 “ARV A” - AUTOMA TIC RAIL VOL T AGE ADJUSTMENT CIRCUITR Y : AMPLIFIER MODE SWITCH BA TTERY VOL T AGE: INDUCTION AND TUNNEL F AN COOLING: PROTECTION CIRCUITR Y : Cadence RS amplifiers feature "ARV A" circuitry in their power supply .
INST ALLA TION BASICS 5 INST ALLA TION BASICS: REMOTE TURN ON CONECTION: STIFFENING CAP ACITOR DIRECT CONNECTION: USING THE RS AMPLIFIERS IN CONJUNCTION WITH A MUL TI- CHANNEL AMPLIFIER: POWER/GROUND WIRING: Before you begin with your installation disconnect the NEGA TIVE (-) terminal from your car's battery .
MOUNTING 6 MOUNTING THE RS AMPLIFIERS: 1 A B A 2 3 Choose a convenient mounting location with unobstructed airflow . 1 - Mount and fasten amplifier bracket A onto the mounting surface, with two screws as shown. 2 - Slide the amplifier so that hook B engages with bracket A.
Remote turn on Remote turn on Mode switch Line level inputs from head unit S tereo RCA cable from RS LINE OUT to highs amp LINE IN CPR Remote Control Woofer 1 ohm minimum High frequency speakers Groun.
USING THE CPR REMOTE CONTROL WITH THE RS AMPLIFIERS 8 CPR (COMPETITION PODIUM REMOTE) BASICS LEVEL CONTROL: BURST BUTTON: DIGIT AL BA TTERY VOL T AGE MONITOR: POWER BARGRAPH: INST ALLA TION: The optional CPR remote control can be used for street or SPL competitions alike.
ADJUSTING THE SYSTEM 9 SETTING THE TOP P ANEL CONTROLS ADJUSTING THE SYSTEM AUDIO PREAMP INPUT AUDIO PREAMP OUTPUT USING THE BUIL T-IN LOW P ASS ELECTRONIC CROSSOVER SUBSONIC FIL TERING . PHASE SHIFT CONTROL AMPLIFIER MODE SWITCH The RS amplifiers feature RCA preamp inputs.
MASTER/SLA VE CONNECTION DIAGRAM MONO BRIDGING 2 AMPLIFIERS INTO 1 WOOFER 10 Mode switch Mode switch 2 ohm minimum AMPLIFIER MODE SWITCH, INPUTS AND REMOTE CONTROL Set the AMPLIFIER MODE switches as shown Connect the source to the master amplifier inputs, and an optional CPR remote control to the master , as shown.
MONO BRIDGING MUL TIPLE P AIRS OF AMPLIFIERS 2 OR MORE AMPLIFIERS WITH SEP ARA TE SPEAKERS IMPORT ANT : Note the reverse speaker phase on 2nd amplifier IMPORT ANT : Reverse the speaker phase on every .
BASIC SPEAKER WIRING DIAGRAMS FOR V ARIOUS LOADS 12 4 OHM 8 OHM 2 OHM 4 OHM 1 OHM TO AMPLIFIER 2 OHM TO AMPLIFIER 4 OHM TO AMPLIFIER 8 OHM TO AMPLIFIER 1 OHM TO AMPLIFIER 2 OHM TO AMPLIFIER + + + + + .
ADV ANCED SPEAKER WIRING DIAGRAMS FOR V ARIOUS LOADS 13 P ARALLEL: DUAL VOICE COIL SPEAKERS 3 X DUAL VC 8 OHM SPEAKERS WITH P ARALLEL VOICE COILS, IN P ARALLEL 2 X DUAL VC 4 OHM SPEAKERS WITH P ARALLE.
TROUBLESHOOTING 14 GENERAL TOOLS NEEDED NO SOUND By utilizing this process of elimination you can determine where the cause of the problem is. If the amplifier goes in to diagnostic with nothing connected to it, and you are sure of proper power and ground, please contact our service dep artment for further help ay 732 370 5400.
SPECIFICA TIONS 15 Due to constant product improvements, these specifications are subject to change without notice. High current rated powers are at amplifier minimum distortion and are for competition purposes. Not responsible for typographical errors.
MONO CLASS D AMPLIFIERS.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Cadence MONO CLASS D è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Cadence MONO CLASS D - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Cadence MONO CLASS D imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Cadence MONO CLASS D ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Cadence MONO CLASS D, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Cadence MONO CLASS D.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Cadence MONO CLASS D. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Cadence MONO CLASS D insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.