Manuale d’uso / di manutenzione del prodotto BRIM-T6 del fabbricante Cabletron Systems
Vai alla pagina of 38
BRIM-T6 USER’S GUIDE.
.
i NO TICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes ha ve been made.
NO TICE ii FCC NO TICE This device complies with P art 15 of the FCC rules. Operation is subject to the following two conditions: (1) this de vice may not cause harmful interference, and (2) this device must accept any interference recei ved, including interference that may cause undesired operation.
NO TICE iii PR OGRAM LICENSE A GREEMENT IMPOR T ANT : Before utilizing this product, carefully read this License Agreement. This document is an agreement between you, the end user , and Cabletron Systems, Inc.
NO TICE iv EXCLUSION OF W ARRANTY & DISCLAIMER OF LIABILITY 1. EXCLUSION OF W ARRANTY . Except as may be specifically provided by Cabletron in writing, Cabletron makes no warranty , expressed or implied, concerning the Program (including Its documentation and media).
v CONTENTS CHAPTER 1 INTRODUCTION 1.1 USING THIS MANU AL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.2 INTRODUCING THE BRIM-T6 . . . . . . . . . . . . . . . . . . . . . 1-2 1.3 BRIM SPECIFICA TIONS . . . . . . . . . . . . . . . . . .
CONTENTS vi APPENDIX B MEDIA SPECIFICA TIONS AND REQUIREMENTS B.1 FIBER OPTIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 B.2 SHIELDED TWISTED P AIR (STP) . . . . . . . . . . . . . . . . . . B-2 B.3 UNSHIELDED TWISTED P AIR (UTP) .
1-1 CHAPTER 1 INTR ODUCTION W elcome to the BRIM-T6 USER’S GUIDE . This manual describes BRIM-T6 features, installation instructions, and operating procedures.
INTRODUCTION 1-2 1.2 INTRODUCING THE BRIM-T6 The BRIM-T6 (see Figure 1-1) is a SNMP-manageable daughterboard that provides a bridging and routing interf ace for a v ariety of Cabletron Systems’ Intel i960-based intelligent T oken Ring and Ethernet host de vices (for e xample, the MicroMMA C-T concentrator and the EMM-E6 management module).
INTRODUCTION 1-3 Jumper Selectab le Ring Speed The BRIM-T6 has a ring speed selection jumper on its component board that you can use to select operating ring speeds of either 4 or 16 megabits per second (4 or 16 Mbps). See Section 2.3 for instructions on setting the ring speed for the BRIM-T6.
INTRODUCTION 1-4 1.3 BRIM SPECIFICA TIONS En vironment Storage temperature: - 30 ° to 90 ° C Operating temperature: 5 ° to 40 ° C Operating humidity: 5% to 95% non-condensing Safety This unit meets the safety requirements of UL 1950 (without D3 de viations), CSA C22.
INTRODUCTION 1-5 Networking Pub lications The Simple Book, An Intr oduction to Management of TCP/IP-based Internets, Marshall T . Rose, Prentice-Hall, Inc.
INTRODUCTION 1-6.
2-1 CHAPTER 2 INST ALLA TION This chapter describes ho w to unpack, configure, and install the BRIM-T6. Because the operation of a BRIM-T6 requires a properly attached and configured T oken Ring Port Interface Module (TPIM), this chapter also includes TPIM configuration and installation instructions.
INST ALLA TION 2-2 2.2.1 Installing the BRIM-T6 into a MIM T o install the BRIM-T6 into a Media Interface Module (MIM), refer to Figure 2-1 and Figure 2-2 and follo w these steps: 1. Disconnect all cables from the MIM as necessary . Note all prior cable-to-port connections to ensure proper reconnection.
INST ALLA TION 2-3 Figure 2-2. Installing the BRIM-T6 5. Insert the connector pins on the underside of the BRIM into the motherboard connector on the MIM by pressing do wn firmly on the rear section of the BRIM until the pins slide all the way into the connector holes.
INST ALLA TION 2-4 2.2.2 Installing the BRIM-T6 into a Standalone Device Standalone de vices hav e the same physical setup for BRIM installation as MIMs. So you can refer to Figure 2-1 and Figure 2-2 when installing a BRIM-T6 into a standalone de vice.
INST ALLA TION 2-5 The BRIM-T6 default ring speed setting is 16 Mbps. The other av ailable setting is 4 Mbps. T o configure the ring speed, refer to the settings illustrated in Figure 2-3 and follo w these steps: 1.
INST ALLA TION 2-6 2.4 CONFIGURING AND INST ALLING TPIMs This section describes ho w to configure TPIMs and install them into the BRIM-T6. 2.4.1 Configuring TPIMs Cabletron TPIMs are shipped pre-configured to support Ring In/Ring Out (RI/R O) communications.
INST ALLA TION 2-7 Figure 2-4. TPIM Configuration for Station Applications NO TE : If the switch locations on a TPIM do not match the example locations illustrated in Figur e 2-4, r efer to the TPIM Refer ence Card included with the TPIM. The TPIM Refer ence Car d outlines switch locations and settings.
INST ALLA TION 2-8 2.4.2 Installing TPIMs T o install a TPIM into the BRIM-T6, refer to Figure 2-5 and follo w these steps: 1. Slide the TPIM into the TPIM slots until the connector pins in the BRIM are fully inserted into the connector on the TPIM. 2.
3-1 CHAPTER 3 CONNECTING T O THE NETW ORK This chapter describes ho w to connect the follo wing standard network cable types to the BRIM-T6: • Shielded T wisted Pair (STP) • Unshielded T wisted Pair (UTP) • Fiber Optic NO TE : Remember that the BRIM-T6 is designed and configur ed for connection to network concentrator Station ports only .
CONNECTING T O THE NETWORK 3-2 3.2 CONNECTING UTP SEGMENTS The TPIM-T2 pro vides an RJ45 interface for connecting UTP cable segments (see Appendix A for pinouts). T o connect a UTP segment to a TPIM-T2, insert the RJ45 connector into the RJ45 port as sho wn in Figure 3-2.
CONNECTING T O THE NETWORK 3-3 • Dust, dirt, and other contaminants on the ends of the connectors create data transmission problems. A void touching the ends of the connectors. If the ends become dirty , clean them with alcohol using a soft, clean, lint-free cloth.
CONNECTING T O THE NETWORK 3-4.
4-1 CHAPTER 4 MONIT ORING AND TROUBLESHOO TING This chapter describes ho w to use the LANVIEW LED system to monitor the operation of the BRIM-T6. It also describes procedures for resolving problems you may encounter establishing a link to a network via the BRIM-T6 interface.
MONIT ORING AND TR OUBLESHOO TING 4-2 XMT (T ransmit) When flashing Green, XMT indicates that the BRIM-T6 is transmitting traf fic to the T oken Ring network.
MONIT ORING AND TR OUBLESHOO TING 4-3 4.2 CHECKING THE CONNECTION This section provides a checklist for troubleshooting netw ork connection problems. The LNK LED on the TPIM lights green when there is an established link between the BRIM-T6 and the de vice at the other end of the media connection.
MONIT ORING AND TR OUBLESHOO TING 4-4 • V erify that STP and UTP connectors (DB9 and RJ45) are pinned properly . For fiber , verify that the recei ve-to-transmit connection of strands between de vices is correct. • Check that the connection meets the dB loss limit and media specifications outlined in Appendix B.
A-1 APPENDIX A TPIM SPECIFICA TIONS A.1 TWISTED P AIR TPIM PINOUTS: ST A TION MODE Figure A-1 illustrates pinouts for TPIMs that support twisted pair cable (STP and UTP) and that are also configured to support Station applications. . Figure A-1. TPIM-T1/T2/T4 Pinouts for Station Mode.
TPIM SPECIFICA TIONS A-2 The transmitter po wer and recei ve sensiti vity lev els gi ven in T able A-1 and T able A-2 are Peak Power Le vels after optical ov ershoot. A Peak Power Meter must be used to correctly compare the gi ven v alues to those measured on any particular port.
B-1 APPENDIX B MEDIA SPECIFICA TIONS AND REQUIREMENTS This Appendix provides information about cabling media (Fiber , STP , UTP) used with the BRIM-T6. B.1 FIBER OPTIC T able B-1 defines total signal attenuation tolerances for both single-mode and multimode fiber cabling.
MEDIA SPECIFICA TIONS AND REQ UIREMENTS B-2 B.2 SHIELDED TWISTED P AIR (STP) STP cable categories are listed as follo ws: • IBM T ype 1 consists of two STP lengths of 22 A WG solid wire for data. There are three v ersions of T ype 1: Indoor , Outdoor , and Plenum.
MEDIA SPECIFICA TIONS AND REQ UIREMENTS B-3 Maximum Lobe Length Lobe length is the physical length of the cable connecting a station to its TCU port. T able B-3 shows maximum lobe length according to ring speed. The length figures are for total lengths of STP cable only .
MEDIA SPECIFICA TIONS AND REQ UIREMENTS B-4 UTP consists of four pairs of 24 A WG solid wire for data or voice communication and is typically used to wire cable runs within the walls of buildings. In some installations, e xisting UTP building wiring can be used for T oken Ring cabling.
MEDIA SPECIFICA TIONS AND REQ UIREMENTS B-5 Maximum Lobe Lengths The lobe length is the physical length of the cable connecting a station to its TCU port. T able B-5 shows maximum lobe length according to ring speed. Length figures are for total lengths of UTP cable only .
MEDIA SPECIFICA TIONS AND REQ UIREMENTS B-6.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Cabletron Systems BRIM-T6 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Cabletron Systems BRIM-T6 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Cabletron Systems BRIM-T6 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Cabletron Systems BRIM-T6 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Cabletron Systems BRIM-T6, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Cabletron Systems BRIM-T6.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Cabletron Systems BRIM-T6. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Cabletron Systems BRIM-T6 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.