H5M 10267.0000D 7/00 © 1988 BUNN-O-MATIC CORPORATION B UNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 BU N N ® OPERA TING .
2 CONTENTS Introduction ................................................. 2 Warranty ...................................................... 2 User Notices ................................................ 3 Electrical Requirements .....................
3.
4 ELECTRICAL REQUIREMENTS CAUTION - The dispenser must be disconnected from the power source until specified in Initial Set-Up. The H5M dispenser requires 2-wire, grounded service rated 120, 208, or 240 volts ac, 20 amp, single phase. The H5MA, 230V-CE dispenser requires 2-wire, grounded service rated 230 volts ac, 40 amp, single phase, 50/ 60Hz .
5 INITIAL SET -UP CAUTION - The dispenser must be disconnected from the power source throughout the initial set-up, except when specified in the instructions. 1. Remove the upper rear panel and rotate the control thermostat knob fully counterclockwise to the “ OFF ” position and r eplace the panel.
6 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T ech- nical Service Department.
7 TROUBLESHOOTING (cont.) Problem Probable Cause Remedy Automatic refill will not operate after drawing hot water . Water flows into the tank con- tinuously (Dispenser discon- nected from power source). Water flows into the tank con- tinuously (Dispenser connected to power source).
8 TROUBLESHOOTING (cont.) Problem Probable Cause Remedy Water boils continuously . Dispenser is making unusual noises. Ready indicator will not light. (when temperature is within 4 ° of its selected setting.) 1. T emperature control 2. Lime build-up 1.
9 SERVICE This section provides procedures for testing and replacing various major components used in this dis- penser should service become necessar y .
10.
11.
12 SERVICE (cont.) Solenoid Valve Location: The solenoid valve is located inside the rear of the dis- penser on the right side near the bottom. 6. Check the solenoid valve for coil action.
13.
14 FIG. 10 THERMOSTAT WIRING BLU/BLK to Limit Thermostat BLK to T erminal Block P1782 SERVICE (cont.) Thermostat Location: The mechanical thermostat is located inside the upper rear panel. T o test the thermostat, access will also be needed to the terminal block located inside the bottom access panel.
15 SERVICE (cont.) Liquid Level Board Location: The liquid level board is located inside the lower panel. Test Procedure: 1. Disconnect the dispenser from the power sour ce. 2. Remove the blue wire from terminal 1 and the pink wire from terminal 4 of the circuit board.
16 15. Move the probe's flat end to the dispenser hous- ing. The indication must be 0. 16. Move the probe's flat end away from the dispenser housing. The indication should again be: a.) 100 to 120 volts ac for 100 to 120 volt models, b.) 200 to 240 volts ac for 200 to 240 volt models, c.
17 Location: The contactor is located on the component bracket inside the lower rear panel. T est Pr ocedures: 1. Disconnect the dispenser from the power sour ce. 2. Disconnect the black wire from the contactor coil to the limit thermostat and black wire from the red wire on the main harness on two wire 240V mod- els.
18 BLK to left Tank Heater RED to Terminal Block(L2) BLK to Terminal Block (L1) RED to Right Tank Heater BLK to Limit Thermostat RED from Main Harness P1725 FIG.14 CONTACTOR WIRING contactor . Removal and Replacement: 1. Disconnect all the wires from the contactor .
19 4 3 12 LIQUID LEVEL BOARD BLU/BLK TANK HEATER 120 VOLTS A C 2 WIRE SINGLE PHASE 10243.0000D 1/99 © 1987 BUNN-O-MATIC CORPORATION SCHEMATIC WIRING DIAGRAM H5M L1 N BLK BLK BLK SOL WHI GREEN BLU WHI.
20 WIRING DIAGRAMS 4 3 12 LIQUID LEVEL BOARD BLK SW& THERMOSTAT 10262.0001A 11/99 © 1999 BUNN-O-MATIC CORPORATION SCHEMATIC WIRING DIAGRAM H5MA, 230V CE L1 L2 BLK SOL GREEN BLU BLK BLK (PROBE) P N K RED RED RED BLU/BLK BLK RED-12 BLK-12 N.O. N.O.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bunn H5M è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bunn H5M - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bunn H5M imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bunn H5M ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bunn H5M, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bunn H5M.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bunn H5M. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bunn H5M insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.